Price
$2,268.00CAD
Stock
100+ In Stock

  • Input Signal - Digital Communication - FOUNDATION Fieldbus Protocol
  • Applicable Control Valve - Single Acting Actuator
  • Connections - Electrical Connection: 1/2 NPT
  • Optional Specifications - With Pressure Gauge
  • Pressure Gauge - Scale And Calibration Unit: bar

Specifications

Actuator Type

  • Double-Acting Actuator
  • Pneumatic
  • Single-Acting Actuator

Air Consumption

  • 0.20 scfm (0.32 Nm³/hour) at psi: 20.31 (kPa: 140, bar: 1.4) - Max.
  • 0.62 scfm (1.0 Nm³/hour) at psi: 58.02 (kPa: 400, bar: 4) - Max.

Ambient Temperature Range

  • -10° to 85° C (14° to 185° F) - for High Temperature Double-Acting Actuator
  • -40° to 60° C (-40° to 140° F) - for Standard Double-Acting Actuator
  • -40° to 85° C (-40° to 185° F) - Single-Acting Actuator

Approvals & Certifications

  • CE
  • CSA Explosion-proof Approval
  • EMC - EN 61326-1 Class A, Table 2, EN 61326-2-5
  • FM - Explosion-proof, Intrinsically Safe & Non-Incendive
  • TIIS - Flameproof

BSP Connection

  • 1/8” BSPT Female - Pressure Gauge Connection

Communication

  • FOUNDATION Fieldbus

Current

  • 1,000 A (1 x 40 µs), 100 times - for Repeating Lightning Protection
  • 17 mA - Max.
  • 41 mA - Max.
  • Maximum

Diameter

  • Outer Diameter: 0.31” to 0.47” (8 to 12 mm) for Applicable Cable - Attached Flameproof Packing Adapter

Display

  • 10-Segment

Electrical Connectors

  • 1/2” NPT
  • G 1/2”
  • G 1/2” Female - Attached Flameproof Packing Adapter
  • M20
  • PG13.5 Female

Enclosure Finish

  • Deep Sea Moss Green (Munsell 0.6 GY3.l / 2.0 or Equivalent)
  • Epoxy Resin Coating - Coating Change for Painting
  • Polyurethan Resin Baked Finish

Enclosure, Body Material

  • Aluminum - Die Cast
  • Stainless Steel JIS SUS304 - Pressure Gauge Case

Environmental Protection

  • IP65
  • IP66
  • NEMA 4X

Flow Capacity

  • 4.1 scfm (6.6 Nm³/hour) at psi: 20.31 (kPa: 140, bar: 1.4) - Max.
  • 8.5 scfm (13.7 Nm³/hour) at psi: 58.02 (kPa: 400, bar: 4) - Max.

Function

  • Auto Tuning Function
  • Contiuous Diagnostics
  • Link Master Function
  • Valve Position Detecting

Humidity

  • 5 to 95 % Relative Humidity at 40° C (104° F) - Ambient Humidity Limits

Hysteresis

  • 0.3 % of Span - Single-Acting Actuator
  • 0.5 % of Span - Double-Acting Actuator
  • 0.6 % of Span - for Single-Acting Actuator Valve Linkage
  • 1 % of Span - for Double-Acting Actuator Valve Linkage

Linearity

  • ± 0.5 % of Span (Including Linkages) - Single-Acting Actuator
  • ± 1.0 % of Span - for Single-Acting Actuator Valve Linkage, for Double-Acting Actuator (Including Linkages)
  • ± 2 % of Span - for Double-Acting Actuator Valve Linkage

Mounting

  • Direct Connection for Rotary Valve
  • Front of Actuator with Bracket

Mounting Position Effect

  • ± 0.3 % of Span at 90° - Position Effect

NPT Connection

  • 1/4” NPT Female - Air Connection
  • 1/8” NPT Female - Pressure Gauge Connection

PID Configuration

  • PID - One/Two PID Control Function

Power Supply

  • 9-32 Vdc - Lightning Protection

Pressure Range

  • psi: 0 to 150 (MPa: 0 to 1, bar: 0 to 10) for Pressure Gauge Scale - Double-Acting Cylinder
  • psi: 0 to 60 (kPa: 0 to 400, bar: 0 to 4) for Pressure Gauge Scale - Diaphragm, Single-Acting Cylinder

Pressure Type

  • Gauge

Ratio

  • 30:1 - Equal Percentage
  • 50:1 - Equal Percentage

Rotation

  • ± 10° to ± 25°, 10 to 100 mm (0.4” to 4.0”) - Linear Motion
  • 20° to 90° - Rotary Motion

Shock

  • 10 G

Span Effect

  • Within 300 % of Span - Span Adjustment Range

Supply Pressure

  • psi: 20 to 60 (kPa: 140 to 400, bar: 1.4 to 4) - for Diaphragm, Single-Acting Actuator Air Supply Pressure
  • psi: 30 to 100 (Kpa: 200 to 700, bar: 2 to 7) - for Double-Acting Actuator Air Supply Pressure

Supply Voltage

  • 9-17.5 Vdc - for Intrinsically Safe Typical FISCO Model
  • 9-24 Vdc - for Intrinsically Safe Typical Entity Model
  • 9-32 Vdc - for General Use & Flameproof Typical, Conditions of Communication Line

Temperature Effect

  • ± 0.08 % of Span/°C - Ambient Temperature Effect

Vibration

  • 2 G, 15 to 2,000 Hz
  • 4 mm at 5 to 15 Hz

Vibration Effect

  • ± 2 % of Span at 2 G (15 to 2,000 Hz)

Zero Offset

  • -15 to 85 % of Span - Zero Adjustment Range
show more