Price
$1,763.00
CAD
Stock
25+ In Stock
- Power Cord - GB Standard
Specifications
Accuracy
- ± 0.1 % of Reading ± 1-Digit - Frequency Measurement Function
- ± 0.5 % of Full Scale - Analog Input & DA Output Functions
- ± 1.5 % of Reading ± 1.5 % of Range - Harmonic Measurement Function
- ± 2.0 % of Reading ± 1.5 % of Range - Harmonic Measurement Function
- ± 20 ppm at Typical 23° C (73.4° F) - Integration Time & Real Time Accuracy
- ± 3.0 % of Reading ± 1.5 % of Range - Harmonic Measurement Function
Applications
- Electrical Equipment at Factories & Building
- Food Processing at Factories & Building
- Printing Machinery
- Semiconductor Manufacturing Equipment
Approvals & Certifications
- BS
- CE
- CSA
- cULus Listed
- SAA
- VDE
Channels
- 2-Channels - Number of Input Channels
- 4-Channels - Number of Output Channels
Communication
- Baud Rate: 1,200, 2,400, 4,800, 9,600, 19,200, 38,400 bit/sec
- EIA RS-232
Consumption
- 10 W Approximately (Normal Operation) - Max.
- 20 W Approximately (During Charging of NiMH Battery Pack) - Max.
- 30 VA Approximately (Normal Operation) - Max.
- 60 VA Approximately (During Charging of NiMH Battery Pack) - Max.
Current
- 20-3,600 Arms - Max.
Display
- 4-Digits - Items Other Than Power Quantity
- 5.7-inch STN Monochrome LCD Display (320 x 240 Dots) with Backlight
- 6-Digit Display
- Bar Graph
- Vector
Electrical Connectors
- D-Sub 9-Pin Connector - Communication Function
Frequency
- 45 to 65 Hz - Fundamental Wave Frequency
Humidity
- 30 to 75 % RH, 23° C (73.4° F) ± 5° C (± 9° F) - Accuracy Guarantee Temperature & Humidity Ranges
- 5 to 80 % RH, Non-Condensing - Operating Temperature
- 90 % RH, Non-Condensing - Storage Temperature
Input
- 100 mV/1 V / 5 Vdc
- 150-1,000 V
- TTL Level or Contact - Control Input
Insulation Resistance
- 50 MΩ at 500 Vdc or greater between Voltage Input Terminals & Case, between Voltage Input Terminals & Current Input Terminals / DC Power Terminals / External Interface Terminals
Measurement Accuracy
- ± 1-Digit - Power Quantity & Demand Measurement Function
Measuring Range
- 0 mVarh to 9,99,999 GVarh - Reactive Power Quantity (Lagging)
- -0 mVarh to -9,99,999 GVarh - Reactive Power Quantity (Leading)
- 0 mWh to 9,99,999 GWh - Active Power Quantity (Consumption)
- -0 mWh to -9,99,999 GWh - Active Power Quantity (Regeneration)
Measuring Time
- 20 ms Approximately - Sampling Rate
Operating Temperature
- 5° to 40° C (41° to 104° F)
Output
- ± 1 Vdc of the Rated Value for Each Range Power Quantity Depends on the Output Rate
- TTL - Control Output
Power Requirement
- 6 AA Alkaline Batteries
- One NiMH Rechargeable Battery
Power Supply
- 100-240 Vac, 50/60 Hz
Resistance
- 1.3 MΩ Approximately - Input Resistance (Voltage)
- 100 kΩ - Input Resistance (Current)
- 22 ohms ± 5 % - Output Resistance
Resolution
- Polarity + 11-bits
Storage Temperature
- -20° to 60° C (-4° to 140° F)
Supply Voltage
- 1,000 Vrms - Max.
- 3.32 kVac RMS for One Minute (Sensed Current: 1 mA) between Voltage Input Terminals & Current Input Terminals / DC Power Terminals / External Interface Terminals
- 5.55 kVac RMS for One Minute (Sensed Current: 1 mA) between Voltage Input Terminals & Case
Temperature Coefficient
- ± 0.02 % of Full Scale/°C or Less - Analog Input & DA Output Functions
- ± 0.03 % of Range/°C - Voltage
- ± 0.05 % of Range/°C - Current
Update Time
- 30 minutes or more - Warm-Up Time
- Approximately 0.5 second - Display Updating Interval
Wiring
- 2-Wire - Single-Phase
- 3-wire - Single-phase, 3-phase
- 4-wire - 3-phase