Price
$1,622.00 CAD
Stock
50+ In Stock

  • Mounting - 1"-Thread
  • Nominal Length - 180 mm
  • Model - Without Integrated Purge Air Unit

Specifications

Brand

Certifications & Approvals

  • CE

Measuring Range

  • Scattered Light Intensity: 0 to 7.5 SI / 0 to 3,000 SI

Response Time

  • 0.1 to 600 s

Accuracy

  • ± 2 % of Measuring Range Full Scale

Process Temperature

  • -40° to 220° C

Process Pressure

  • With Instrument Air (Provided by the customer): -50 to 100 hPa
  • With External Purge Air Unit: -50 to 30 hPa
  • With Intergrated Purge Air Unit: -50 to 10 hPa

Process Gas Humidity

  • Non-Condensing

Ambient Temperature

  • -40° to 60° C

Enclosure Rating

  • IP65
  • IP54

Analog Output

  • 1 Output: 0/4 ... 20 mA, 750 Ω Electrically Isolated

Digital Output

  • 3 Relay Contacts: 48 V, 1 A for Status Signals

Digital Input

  • 4 Inputs: for External Maintenance Switch, Automated Operational Check, Linearity Measurement, Calibration Curve Switching, or Filter Monitoring

Communication

  • RS-485
  • Modbus
  • PROFIBUS DP
  • Ethernet

Power Supply

  • Supply via MCU Control Unit or an External Power Supply
  • 24 Vdc

Power Consumption

  • Without Integrated Purge Air Unit: ≤ 4 W
  • With Integrated Purge Air Unit: ≤ 30 W

Indication

  • LC Display
  • Status LEDs: “Power,” “Failure,” and “Maintenance Request”
show more