EE Analog Magnetostrictive Linear Position Sensor
Brand: Temposonics an Amphenol CompanyRobust, non-contact and wear free, the Temposonics linear position sensors provide best durability and accurate position measurement solutions in harsh industrial environments.
The position measurement accuracy is tightly controlled by the quality of the waveguide which is manufactured by MTS Sensors. The Temposonics E-Series EE position sensor is designed for the installation into a hydraulic cylinder.
Because of his compact design the EE sensor is the perfect solution for small cylinders with limited space for the integration in a measuring system.
The increased operating temperature capability allows the sensor to be used in a wide range of industrial applications.
Specifications
Approvals & Certifications
- ISO 9001 (DQS)
Approvals & Certifications
- CE
- EMC Electromagnetic Emission EN 55011, Class B: 2009 + A1: 2010, Immunity EN 61326-1: 2006
Cable Length
- 4.3 to 24” (110 to 610 mm)
Consumption
- Current Consumption: 50-140 mA
Electrical Connectors
- 6-Pin Molex PicoBlade Connector System
Electrical Protection
- Overvoltage Protection: up to 36 Vdc
- Polarity Protection: up to -30 Vdc
Enclosure, Body Material
- Sensor Electronics Housing: AISI 303 Stainless Steel 1.4305
Environmental Protection
- Ingress Protection: IP67 (with Professional Mounted Housing & Connectors)
- Ingress Protection: Sensor with Flat Connector IP30
Humidity
- 90 % Relative Humidity, Non-Condensing
Length
- Stroke: 2 to 100” (50 to 2,540 mm)
Linearity
- ≤ ± 0.02 % of Full Scale (Min. ± 60 µm)
Load
- 0 to 500 ohms for Current Output
Materials of Construction
- Sensor Rod: 304L Stainless Steel 1.4306
Operating Pressure
- psi: 0 to 5,076 (kPa: 0 to 35,000, bar: 0 to 350)
Operating Temperature
- -40° to 85° C (-40° to 185° F)
Operating Voltages
- 24 Vdc (-15 / 20 %)
Output
- 20-4 mA
- 4-20 mA
Principle of Operation
- Magnetostrictive Principle
Repeatability
- < ± 0.002 % of Full Scale (Min. ± 20 µm)
Resolution
- Infinite
Shock
- 100 G (Single Shock) IEC 60068-2-27
Vibration
- 15 G (10 to 2,000 Hz), IEC 60068-2-6 (Resonance Frequencies Excluded)
Voltage
- Dielectric Strength: 500 Vdc (0 V Ground to Machine Ground)
- Industrial Applications
- Wood Working