Accuracy
- ± 0.25 % of Span (At Indications Below 50 % of Span)
- ± 0.5 % of Rate (At Indications 50 % of Span or More)
- ± 0.5 % of Span (At Indications Below 50 % of Span)
- ± 1 % of Rate (At Indications 50 % of Span or More)
- ± 1 % of Span
Ambient Temperature Range
- -20° to 50° C (-4° to 122° F)
Approvals & Certifications
- Calibration
- Hydrostatic Pressure Test
- Material Certificate
Approvals & Certifications
- CSA Explosion-proof for Class I, Groups B, C, D, Class II, Groups E, F, G, Class III
- EMC AS/NZS CISPR 11
- FM 3600, FM 3615, FM 3810, Explosion-proof for Class I, Div. 1, Groups A, B, C, D
- FM Dust-Ignition-proof for Class II/III, Div. 1, Groups E, F, G
- TIIS Construction: Ex d E IIC T4 X: Converter, Flameproof Flow Tube, Increased Safety: Gas Group & Temperature Class, IIC T4
Cable Length
- 6,560 feet (2,000 metres) - Max.
Capacity
- 0.22 µF or Less (Including Cable) - Load Capacity
Communication
- BRAIN (Superimposed on a 4-20 mA DC Signal)
Damping Adjustment
- Settable from 1 to 200 seconds (63 % Response Time)
Diagnostics
- Converter Failure
- Erroneous Setting
- Flow Tube Failure
Display
- 7-Segment LCD (with No Backlight)
Electrical Connectors
- ANSI 1/2” NPT Female
- DIN PG13.5 Female
- ISO M20 x 1.5 Female
- JIS G 1/2” Female
- M4 Screw Terminal - Terminal Connection
Enclosure Finish
- Deep Sea Moss Green (Equivalent to Munsell 0.6 GY3.1/2.0) - for Cover
- Epoxy Coated
- Frosty White (Equivalent to Munsell 2.5Y8.4/1.2) - for Enclosure/Body (Aluminum Alloy)
- High Anti-Corrosion Coating
- Polyurethane Corrosion-Resistant Coating
Enclosure, Body Material
- Aluminum Alloy
- SCS11 for 0.5” (15 mm) Size - Flow Tube Material
- Stainless Steel
- SUS304 for 1” to 8” (25 to 200 mm) Size - Flow Tube Material
Environmental Protection
- IP66
- IP67
- NEMA 4X
- Water-Proof
Flange Size - 1-1/2” (DN 40)
- 1-1/2” (DN 40) - 150# ANSI
- 1-1/2” (DN 40) - 300# ANSI
- 1-1/2” (DN 40) - JIS 10K
- 1-1/2” (DN 40) - JIS 20K
- 1-1/2” (DN 40) - JIS F12 (75M)
- 1-1/2” (DN 40) - PN 10
- 1-1/2” (DN 40) - PN 16
Flange Size - 1” (DN 25)
- 1” (DN 25) - 150# ANSI
- 1” (DN 25) - 300# ANSI
- 1” (DN 25) - JIS 10K
- 1” (DN 25) - JIS 20K
- 1” (DN 25) - JIS F12 (75M)
- 1” (DN 25) - PN 10
- 1” (DN 25) - PN 16
Flange Size - 1/2” (DN 15)
- 1/2” (DN 15) - 150# ANSI
- 1/2” (DN 15) - 300# ANSI
- 1/2” (DN 15) - JIS 10K
- 1/2” (DN 15) - JIS 20K
- 1/2” (DN 15) - JIS F12 (75M)
- 1/2” (DN 15) - PN 10
- 1/2” (DN 15) - PN 16
Flange Size - 2” (DN 50)
- 2” (DN 50) - 150# ANSI
- 2” (DN 50) - 300# ANSI
- 2” (DN 50) - JIS 10K
- 2” (DN 50) - JIS 20K
- 2” (DN 50) - JIS F12 (75M)
- 2” (DN 50) - PN 10
- 2” (DN 50) - PN 16
Flange Size - 3” (DN 80)
- 3” (DN 80) - 150# ANSI
- 3” (DN 80) - 300# ANSI
- 3” (DN 80) - JIS 10K
- 3” (DN 80) - JIS 20K
- 3” (DN 80) - JIS F12 (75M)
- 3” (DN 80) - PN 10
- 3” (DN 80) - PN 16
Flange Size - 4” (DN 100)
- 4” (DN 100) - 150# ANSI
- 4” (DN 100) - 300# ANSI
- 4” (DN 100) - JIS 10K
- 4” (DN 100) - JIS 20K
- 4” (DN 100) - JIS F12 (75M)
- 4” (DN 100) - PN 10
- 4” (DN 100) - PN 16
Flange Size - 6” (DN 150)
- 6” (DN 150) - 150# ANSI
- 6” (DN 150) - 300# ANSI
- 6” (DN 150) - JIS F12 (75M)
- 6” (DN 150) -JIS 10K
- 6” (DN 150) -JIS 20K
- 6” (DN 150) -PN 10
- 6” (DN 150) -PN 16
Flange Size - 8” (DN 200)
- 8” (DN 200) - 150# ANSI
- 8” (DN 200) - 300# ANSI
- 8” (DN 200) - JIS 10K
- 8” (DN 200) - JIS 20K
- 8” (DN 200) - JIS F12 (75M)
- 8” (DN 200) - PN 10
- 8” (DN 200) - PN 16
Fluid
- 0.01 µS/cm or more - Fluid Conductivity for Sizes 0.5” to 4” (15 to 100 mm)
- 1 µS/cm or more - Fluid Conductivity for Sizes 6” (150 mm) & 8” (200 mm)
- Glycerin + Ethylene Glycol
Function
- Alarm Output
- Instantaneous Flow Rate Display
- Pulse Output
- Span Setting
- Totalizer Display
Gasket Material
- Chloroprene
- Chloroprene Rubber (Between Earth Ring & Process Flange)
- Fluoro Resin PTFE with Filler (Between Flow Tube Body & Earth Ring)
- Fluororubber (Between Flow Tube Body & Earth Ring)
- Non-Asbestos Joint Sheet Sheathed with Fluoro Resin PTFE (Between Earth Ring & Process Flange)
- Viton (Between Flow Tube Body & Earth Ring)
Humidity
- 5 to 80 % Relative Humidity, Non-Condensing - Ambient Humidity
Insulation Resistance
- 100 megaohms at 500 Vdc - between Power Terminals & Each Output Terminal
- 100 megaohms at 500 Vdc - between Power Terminals & Ground Terminal
- 20 megaohms at 100 Vdc - between Each Output Terminal & Ground Terminal
Load
- 3.3 MH or Less (Including Cable) - Load Inductance
Materials of Construction
Nut & Bolt Material
- Carbon Steel
- Stainless Steel
Output
- 4-20 mA DC - Current Output
Power Supply
- 100-130 Vdc
- 20.4-28.8 Vdc
- 80-264 Vac
Pressure Range
- psi: -14.5 to 580 (MPa: -0.1 to 4, bar: -1 to 40) - Fluid Pressure
Process Temperature
- 70° to 120° C (158° to 248° F)
Pulse Range
- 0.5 to 100 milliseconds - User Selectable (Pulse Width)
- Output Rate: 0.0001 to 1,000 Pps (When Pulse Output Function is Selected) - Pulse Output Function
Repeatability
- ± 0.1 % of Rate (Min. ± 1 mm/sec)
Resistance
- 0 to 750 ohms - Load Resistance for Current Output (4-20 mA DC)
- 10 kiloohms or Larger at 2.4 kHz - Input Impedance of Receiver Connected to the Receiving Resistance
- 10 ohms or Less - Grounding for TIIS Flameproof Typical, Class A or Class C & JIS Class C, JIS Class A
- 100 ohms or Less - Grounding
- 250 to 600 ohms (Including Cable) - Load Resistance
Size
- 0.5” to 8” (15 to 200 mm)
- 5.9” (15 cm) or more (Parallel Wiring Should be Avoided) - Space from Power Line
Supply Voltage
- 1,500 Vac for 1 Minute between Power Terminals & Ground Terminal - Withstanding Voltage
- 120 Vdc - Max.
- 130 Vdc - Max.
- 240 Vac - Max.
- 250 Vac - Max.
Temperature Range
- -10° to 120° C (14° to 248° F) - Fluid Temperature
Torque
- 10.44 In/Lbs or more - Screw Tightening Torque
Wetted Materials
- Alumina Ceramic (99.9 %) - Pipe
- Hastelloy C-276 Equivalent - Earth Ring
- Stainless Steel (SUS316) - Earth Ring
- Titanium - Earth Ring