EXL6 OCS Controller
Brand: HornerLogic engine features 1MB of application memory with a 0.013mS/K logic scan.
Online Programming Mode (making logic changes on the fly without going thru stop mode) is supported.
Features- 640×480 LCD TFT color graphics display with a high resolution resistive touchscreen
- 4 function keys and a system key
- USB 2.0 On-the-Go port (mini-B 5pin) is available for programming
- USB 2.0 Host port (A) is available for exchanging files with USB FLASH drives
- Two (2) RS-232 and one (1) RS-485 port support RTU/Modbus Master/Slave, ASCII In/Out, and PLC/Drive downloadable protocols
- Built-in 10/100 Ethernet port
- Integrated CsCAN port
Displaying prices & availability for Ohio, United States in CAD. Change location.
Models matching criteria: 6
100+ In Stock
$2,007.00
CAD
Does not ship to OH, United States
- Model - HE-EXL1E4: 24 DC In & 16 DC Out, 4 HS In & 2 HS Out, 2 12-Bit Analog In
50+ In Stock
$1,834.00
CAD
Does not ship to OH, United States
50+ In Stock
$829.00
CAD
Does not ship to OH, United States
- Model - HE-EXL1E6: 12 DC In & Out, 4 HS In & 2 HS Out, 6 14-Bit/16-Bit Universal Analog In, 4 12-Bit Analog Out
25+ In Stock
$133.00
CAD
Does not ship to OH, United States
- Model - HE-EXL1E5: 12 DC In & Out, 4 HS In & 2 HS Out, 2 14-Bit/16-Bit Universal Analog In, 2 12-Bit Analog Out
14 In Stock
$1,009.00
CAD
Does not ship to OH, United States
- Model - HE-EXL1E3: 12 DC In & DC Out, 4 HS In & 2 HS Out, 2 12-Bit Analog In
13 In Stock
$1,829.00
CAD
Does not ship to OH, United States
Specifications
Brand
Accuracy
- ± 0.15 % of Full Scale
- ± 0.2 % of Full Scale ± 1° C (± 2° F)
- Clock: ± 20 ppm, Max.
Approvals & Certifications
- CE
- UL
Current
- Maximum
- OpeN Thermocouple Detect Current: 50 NA
- RTD Excitation: 250 µA
Display
- 5.7” VGA TFT (450 Nit Typical)
Frequency
- Maximum
Humidity
- 5 to 95 % - Non-Condensing
Input
- 2 mA/V
- 4 mA/V
- Absolute, Max.
- Range: 0-10 V
- Range: 0-10 Vdc
- Range: 0-20 mA
- Range: 0-60 mV
- Range: 4-20 mA
- Safe Volatage Range: -0.5 to 12 V
- Safe Voltage Range: ± 24 Vdc
- Safe Voltage Range: -0.5 to 15 V
- Safe Voltage Range: -0.5 to 6 V
- Voltage Range: 12-24 Vdc
Input Impedance
- 10 kiloohms
- Current Mode: 100 ohms
- mA: 15 ohms + 1.5 V
- T/C / RTD / mV: > 2 megaohms
- V: 1.1 megaohms
- Voltage Mode: 500 kiloohms
Isolation
- Contact Isolation to Ground: 1,000 Vac
Load Resistance
- Minimum Current Load: 500 ohms
Lower Threshold
- Minimum 3 Vdc
- Negative Logic: -2.1 mA
- Positive Logic: 0.3 mA
Maximum Voltage
- 28 Vdc
- 35 Vdc
Output
- 2 mA/V
- 4 mA/V
- Maximum
- Range: 0-10 Vdc
- Range: 0-20 mA
- Range: 4-20 mA DC
Output Supply
- Maximum
- Minch Voltage: 10 Vdc
Power
- Maximum
- Range 10 to 30 Vdc
Power Requirement
- 230 mA at 24 Vdc
- 25 A for < 1 millisecond at 24 Vdc DC Switched
- 4-20 mA at 12 Vdc
Resolution
- 10-bits
- 14-bits
- 16-bits
- 640 x 480
Response Time
- 150 Nanoseconds
- OFF to ON: 1 millisecond
- One Update Per Ladder Scan Plus 10 milliseconds
RTD Type
- Pt100
- Pt1000
Sensor, Probe Type
- Thermocouple J, K, N, T, E, R, S, B
Storage Temperature
- -40° to 60° C (-40° to 140° F)
Upper Threshold
- Maximum
- Negative Logic: -1.6 mA
- Positive Logic: 0.8 mA
Voltage Drop
- Maximum