Accuracy
- ± (2 % of Reading + 4-Digits) (50/60 Hz) - AC Current
- ± (3 % of Reading + 5-Digits) (50/60 Hz) - AC Current
- ± (5 % of Reading + 4-Digits) (50/60 Hz) - AC Current
- ± (5 % of Reading + 5-Digits) (50/60 Hz) - AC Current
- ± (5 % of Reading + 6-Digits) (40 to 400 Hz) - AC Current
Approvals & Certifications
- EN 61010-2-032 (Category III 300 V)
Approvals & Certifications
Battery Life
- Approximately 15 Hours (Continuous)
Conductor Position Effect
- 2 % for 50 to 200 A (10 mm-Diameter Conductor at Inside the Jaw)
- Within 5-Digits for 0 to 50 A (10 mm-Diameter Conductor at Inside the Jaw)
Consumption
- Approximately 5 mA - Consumed Current
Current
- 10 mA or Less in Proximity to A 10 mm-Diameter Conductor Carrying 50 A
- 200 A (0-200 A) - AC Current
- 20-200 mA - AC Current
Display
- LCD (Digital Display: 1,999 Counts)
External Magnetic Field Effect
- 10 mA or Less in Proximity to A 14.4 mm-Diameter Conductor Carrying 100 A
Humidity
- 85 % Relative Humidity or Less, Non-Condensing - Operating Humidity
Operating Temperature
- 0° to 40° C (32° to 104° F)
Supply Voltage
- 3.7 kVac for One Minute - Withstanding Voltage
- 300 Vrms or Less - Circuit Voltage
Turn-Off Time
- Approximately 10 minutes - Auto Power-Off