EJX120A Draft Range Differential Pressure Transmitter
Brand: Yokogawa Electric CorporationThe high performance draft range differential pressure transmitter EJX120A features single crystal silicon resonant sensor and is suitable to measure liquid, gas, or steam flow as well as liquid level, density and pressure.
EJX120A outputs a 4 to 20 mA DC signal corresponding to the measured differential pressure. Other key features include quick response, remote set-up using communications, diagnostics and optional status output for pressure high/low alarm.
The multi-sensing technology provides the advanced diagnostic function to detect such abnormalities as an impulse line blockage or heat trace breakage.
FOUNDATION Fieldbus and PROFIBUS PA protocol types are also available. All EJX series models in their standard configuration, with the exception of the Fieldbus and PROFIBUS types, are certified as complying with SIL 2 for safety requirement.
Features- Accurately: ± 0.09% Accuracy
- Reliably: ± 0.15% per 1 year Stability
- Quickly: 150 ms Response Time
Specifications
Accuracy
- ± (0.015 + 0.03 URL/Span) % of Span (Includes Terminal-based Linearity, Hysteresis & Repeatability)
- ± 0.09 % of Span (Includes Terminal-based Linearity, Hysteresis & Repeatability)
Alarm
- Down-Scale: -5 %, 3.2 mA DC or Less
- Up-Scale: 110 %, 21.6 mA DC or more
Ambient Temperature Range
- -25° to 80° C (-13° to 176° F)
Approvals & Certifications
- Leak Test
- Material Certificate
- Pressure Test
- SIL, SIL 2 SIL 3 IEC 61508: 2000, Part1 to Part 7
- TÜV (Technischer Uberwachungsverein)
Approvals & Certifications
- ATEX Flameproof & Intrinsically Safe
- CSA Explosion-proof & Intrinsically Safe
- EMC EN 61326-1 Class A, Table 2, EN 61326-2-3, EN 61326-2-5
- FM Explosion-proof & Intrinsically Safe
- IEC Ex Flameproof & Intrinsically Safe
- NAMUR NE43
- PED 2014/68/EU
- PED 97/23/EC
BSP Connection
- 1/2” BSPT Female
- 1/4” BSPT Female
Cable Material
- PVC
Communication
- BRAIN
- FOUNDATION Fieldbus
- HART
- PROFIBUS PA
Damping Adjustment
- 0 to 100 seconds
Diagnostics
- Capsule Temperature
- Configuration Error
- CPU Failure
- Hardware Failure
- Over-Range Error for Differential Pressure
- User-Configurable Process High/Low Alarm for Differential Pressure
Diaphragm Material
- Hastelloy C-276 - Capsule
Display
- 10-Segment - User-Configurable Signal Characterizer for 4-20 mA Output
- 5-Digit Numerical Display
- 6-Digit Unit Display
- Bar Graph
- LCD Display
Distance
- Up to 2 Kilometers - Communication Distance
Drain, Vent Valves & Plug
- 316 Stainless Steel
Electrical Connectors
- 1/2” NPT Female
- G 1/2” Female
- M20 Female
Electrical Rating
- 120 mA DC, Max.
Enclosure Finish
- Anti-Corrosion Coating
- Mint-Green Paint (Munsell 5.6BG 3.3/2.9)
Enclosure, Body Material
- ASTM CF-8M Stainless Steel
- Cast Aluminum Alloy with Polyurethane
Environmental Protection
- IP66
- IP67
- NEMA 4X
Fill Material
- Silicone Oil
Flange Material
- ASTM CF-8M - Cover Flange
Gasket Material
- Fluorinated Rubber
- PTFE Teflon
Humidity
- 0 to 100 % Relative Humidity - Ambient Humidity
Input Impedance
- 10 kiloohms or more at 2.4 kHz
Length
- 1.33” (34 mm) - Standard Vent Length
- 4.6” (119 mm) - Total Vent Length
Load
- 0 to 1,290 ohms - for Operation
- 0.22 µF or Less - Load Capacitance
- 250 to 600 ohms for Digital Communication
- 3.3 MH or Less - Load Inductance
Materials of Construction
- 304 Stainless Steel
- 316 Stainless Steel - Name Plate & Tag
Mounting
- 2” Pipe Mounting Bracket
Mounting Position Effect
- Tilting up to 90° will cause Zero Shift up to 0.4 kPa
NACE & NIST
- NACE MR-0175, ISO 15156
NPT Connection
- 1/2” NPT Female
- 1/4” NPT Female
Nut & Bolt Material
- 316L Stainless Steel
- 660 Stainless Steel
- B7 Carbon Steel
O-Ring Material
- Buna-N - Cover O-Ring
- Fluororubber - Cover O-Ring
Output
- 0-2 Vdc - Low Level
- 3.6-21.6 mA
- 4-20 mA DC (2-Wire)
Output Format
- Transistor Output
Power Supply Effect
- ± 0.005 % Per Volt (From 21.6 to 32 Vdc, 350 ohms)
Pressure Range
- Inches WC: -4 to 4
- kPa: -1 to 1
- mbar: -10 to 10
- mmWC: -100 to 100
- psi: -0.145 to 0.145
Pressure Type
- Differential
Process Connection Material
- ASTM CF-8M Stainless Steel
Process Temperature
- -25° to 80° C (-13° to 176° F)
Response Time
- 150 milliseconds
Screw Material
- 316 Stainless Steel - Zero-Adjustment Screw & Set Screws
Stability
- ± 0.15 % of URL Per Year
Supply Pressure
- psi: -7.25 to 7.25 (kPa: -50 to 50, bar: -0.50 to 0.50) - Silicone Oil
Supply Voltage
- 10.5-30 Vdc - Intrinsically Safe, Typical N or Non-Incendive
- 10.5-32 Vdc - for Lightning Protector
- 10.5-42 Vdc - General Use & Flameproof Typical
- 16.6 Vdc Min. - for Digital Communications BRAIN & HART
- 24 Vdc - up to A 550 ohms Load Can be Used
Temperature Effect
- ± (0.1 % of Span + 0.15 % of URL) - Ambient Temperature Effects Per 28° C (50° F) Change
Temperature Range
- -25° to 80° C (-13° to 176° F)
Update Time
- 45 milliseconds - Differential Pressure
Vibration Effect
- < ± 0.1 % of URL - as Per IEC 60770-1 & Pipeline with Low Vibration Level (10-60 Hz 0.15 mm Displacement / 60-500 Hz 2 G)
- < 0.1 % of URL - as Per IEC 60770-1 & Pipeline with High Vibration Level (10-60 Hz 0.15 mm Displacement / 60-2,000 Hz 3 G)
Wetted Materials
- 316L Stainless Steel
- F316L Stainless Steel
Zero Offset
- External Zero is Continuously Adjustable with 0.01 % Incremental Resolution of Span
Documentation
Data Sheets
- EJX Series FOUNDATION Fieldbus Communication pdf 878 KB
- EJX Series HART 5/HART 7 Communication pdf 2.5 MB
- EJX Series PROFIBUS PA Communication pdf 853 KB
- EJX/EJA-E series NEPSI Certification[Option code: /NF2, /NF21, /NS21, /NS24 and /NS25] pdf 622 KB
- EJX120A Differential Pressure Transmitter pdf 1.3 MB
Certificate
Manual
- EJX and EJA-E Series Differential Pressure and Pressure Transmitters Installation Manual pdf 7.2 MB
- Manual Change 22-24E: EJX-A and EJA-E Series Differential Pressure and Pressure Transmitters pdf 186 KB
- Manual Change 22-25E: EJX/EJA-E series NEPSI Certification[Option code: /NF2, /NF21, /NS21, /NS24 and /NS25] pdf 312 KB