ET SSI Magnetostrictive Linear Position Sensor

Brand: Temposonics an Amphenol Company

Robust, non-contact and wear free, the Temposonics linear position sensors provide best durability and accurate position measurement solutions in harsh industrial environments.

The position measurement accuracy is tightly controlled by the quality of the waveguide which is manufactured by MTS Sensors.

The position magnet is mounted on the moving machine part and travels contact-lessly over the sensor rod with the built-in waveguide.

Specifications

Approvals & Certifications

  • ATEX Ex II 3 G Ex NC IIC T4 Gc II 3D Ex Tc IIIC T130° C Dc IP66/IP68
  • CE
  • CEC
  • EAC
  • IEC Ex
  • NEC

Approvals & Certifications

  • EMC Electromagnetic Emission EN 61000-6-4, Immunity EN 61000-6-2
  • ISO 9001 (DQS)

Cable Material

  • Silicone
  • Teflon

Communication

  • Data Length: 24-bit, 25-bit
  • Synchronous Serial Interface

Consumption

  • Current Consumption: 90 mA Typical, Dependent on Stroke Length

Electrical Connectors

  • Cable Outlet

Electrical Protection

  • Overvoltage Protection: up to 36 Vdc
  • Polarity Protection: up to -30 Vdc

Enclosure, Body Material

  • Sensor Electronics: AISI 303 Stainless Steel 1.4305
  • Sensor Electronics: AISI 316L Stainless Steel, 1.4404

Environmental Protection

  • Ingress Protection Version a & E with Teflon Cable: IP66
  • Version A, E & N with Silicone Cable: IP68 [psi: 29 (kPa: 200, bar: 2) at 30 minutes]

Flange Material

  • AISI 303 Stainless Steel 1.4305
  • AISI 316L Stainless Steel, 1.4404

Humidity

  • 90 % Relative Humidity, Non-Condensing

Length

  • Stroke Length: 1 to 118” (50 to 3,000 mm)

Linearity

  • ≤ ± 0.02 % of Full Scale (Min. ± 60 µm)

Materials of Construction

  • Sensor Rod: AISI 304L Stainless Steel 1.4306
  • Sensor Rod: AISI 316L Stainless Steel, 1.4404

Metric Connection

  • M18 x 1.5-6 G

Mounting Position

  • Any Orientation

Operating Pressure

  • psi: 0 to 5,076 (kPa: 0 to 35,000, bar: 0 to 350)

Operating Temperature

  • -40° to 90° C (-40° to 194° F)

Operating Voltages

  • 24 Vdc (-15 / 20 %)

Principle of Operation

  • Magnetostrictive Principle

Repeatability

  • ≤ ± 0.005 % of Full Scale (Min. ± 20 µm) Typical

Resolution

  • 10 µm
  • 100 µm
  • 20 µm
  • 5 µm
  • 50 µm

Shock

  • 100 G (Single Shock) IEC 60068-2-27

UNF/UNC Connection

  • 3/4”-16 UNF Male-3A

Vibration

  • 15 G (10 to 2,000 Hz), IEC 60068-2-6 (Resonance Frequencies Excluded)

Voltage

  • Dielectric Strength: 700 Vdc (DC Ground to Machine Ground)

  • Harsh Environments