EB5000 Series RF-Admittance Level Transmitter

Brand: FineTek

RF Admittance Level Transmitter utilizes the capacitance formed between the sensing probe and the reference probe or the metal vessel wall to calculate the level of the medium inside the vessel according to the capacitance theory that the capacitance and vessel are proportional increased. 

When the probe is surrounding by the air, little capacitance (CA) is measured by the equivalent capacitor, the capacitance increase gradually as computing media, the max. capacitance (CB ) will be measured while the tank is full, the difference (dC) between CA and CB is proportional to the level (Recommend range dC = 25 ~ 2000 pF).
Features
  • 4-20 mA, 2-wire loop power
  • Low consumption of power (20 mA maximum)
  • High accuracy of linearity (<±1% of full scale or 0.5 pF)
  • Temperature compensation, low temperature effect (±0.2% of full scale/° C or 0.1 pF/° C )
  • Easy calibration (any 2 points for calibration)
  • No blind distance, ideal for different tanks
  • Suitable for high temperature, high pressure and corrosive environment
  • LCD local display

Specifications

Brand

Accuracy

  • ± 0.5 PF
  • ± 1 % of Full Scale

Ambient Temperature Range

  • -40° to 85° C (-40° to 185° F)
  • LCD Monitor: -20° to 85° C (-4° to 185° F)

Approvals & Certifications

  • CE

BSP Connection

  • 1” BSP Male
  • 1-1/2” BSP Male
  • 2” BSP Male
  • 2-1/2” BSP Male
  • 3” BSP Male
  • 4” BSP Male
  • 5” BSP Male
  • 6” BSP Male

Communication

  • HART

Enclosure Finish

  • PFA Coating for Stainless Steel Probe for Rode/Cable Coating Typical, Anti-Wave Tube Typical
  • Polypropylene Coating with Stainless Steel for Two Rode Probe

Environmental Protection

  • IP65

Materials of Construction

  • Weight Material: 304 Stainless Steel
  • Weight Material: PTFE

Measuring Range

  • 20 to 2,000 PF

Media

  • Dielectric Constant > 4 Conductive Material
  • Low-Moisture Material
  • Non-Conductive Material
  • Solids

NPT Connection

  • 1” NPT Male
  • 1-1/2” NPT Male
  • 2” NPT Male
  • 2-1/2” NPT Male
  • 3” NPT Male
  • 4” NPT Male
  • 5” NPT Male
  • 6” NPT Male

Operating Pressure

  • psi: 71 to 569 (kPa: 490 to 3,922, bar: 4.9 to 39.2)

Operating Temperature

  • -40° to 200° C (-40° to 392° F)

Operating Voltages

  • 18-30 Vdc

Output

  • 4-20 mA, 2-Wire

PT/PF/PS (JIS) Connection

  • 1” PF Male
  • 1” PT Male
  • 1-1/2” PF Male
  • 1-1/2” PT Male
  • 2” PF Male
  • 2” PT Male
  • 2-1/2” PF Male
  • 2-1/2” PT Male
  • 3” PF Male
  • 3” PT Male
  • 4” PF Male
  • 4” PT Male
  • 5” PF Male
  • 5” PT Male
  • 6” PF Male
  • 6” PT Male

Sensor, Probe Material

  • 304 Stainless Steel
  • 316 Stainless Steel
  • PFA

Temperature Effect

  • < ± 0.2 % of Full Scale/°C
  • 0.1 PF/°C

show more