DLM2000 Mixed Signal Oscilloscope

Brand: Yokogawa Electric Corporation

The DLM2000 series has two types of filters, one processed at the input circuit and one based on MATH functions. These filters are effective for rejecting unwanted signals, allowing observation of only the desired bandwidths.
Features
  • Lineup includes 200 MHz, 350 MHz, 500 MHz bandwidth models 
  • Lightweight and compact 
  • Large 8.4-inch LCD display 
  • Long memory: Up to 250 Mpoints 
  • High speed sampling: Up to 2.5 GS/s (1.25 GS/s with 4 channels) 

Specifications

Accuracy

  • ± (1 % of Setting + 0.2 mV) for 2-50 mV/div - Offset Voltage Accuracy
  • ± (1 % of Setting + 2 mV) for 100-500 mV/div - Offset Voltage Accuracy
  • ± (1 % of Setting + 20 mV) for 1-10 V/div - Offset Voltage Accuracy
  • ± (1.5 % of 8 Div + Offset Voltage Accuracy) - DC Accuracy
  • ± 0.002 % - Time Base Accuracy

Ambient Temperature Range

  • 23° ± 5° C (73.4° ± 9° F)

Approvals & Certifications

  • CE
  • IEC 61000-3-2 Edition 2.2, EN 61000-3-2 (2,000), IEC 61000-4-7 Edition 2
  • IEEE

Bandwidth

  • -34 dB (Typical Value) - Max.

Communication

  • Bit Rate: 19.2, 9.6, 4.8, 2.4, 1.2 Kbps
  • CAN Bus
  • Ethernet
  • FlexRay
  • GPIB
  • I²C
  • LIN
  • RS-232
  • SENT
  • SPI
  • UART

Consumption

  • 170 VA - Max.

Dead Time

  • Approximately 2.2 µs - Dead Time in N Single Mode

Display

  • 8.4-inch TFT Color Liquid Crystal Display, 1024 x 768 (XGA)

Electrical Connectors

  • 3-Wire - Trigger Typicals
  • 4-Wire - Trigger Typicals
  • RJ45 Connector x 1
  • USB

Frequency

  • 0.01 Hz to 500 MHz - Cut-Off Frequency Setting Range
  • 100 MHz - Max.
  • 150 MHz for 20 mV-50 mV/div & 2 mV-5 mV/div - 1 Megaohm (When Using Passive Probe) & 50 ohms (DLM202x)
  • 200 MHz for 100 mV-100 V/div & 10 mV-500 mV/div - 1 Megaohm (When Using Passive Probe) & 50 ohms (DLM202x)
  • 250 MHz - Max.
  • 300 MHz for 20 mV-50 mV/div & 2 mV-5 mV/div - 1 Megaohm (When Using Passive Probe) & 50 ohms (DLM203x)
  • 350 MHz for 100 mV-100 V/div & 10 mV-500 mV/div - 1 Megaohm (When Using Passive Probe) & 50 ohms (DLM203x)
  • 400 MHz for 20 mV-50 mV/div & 2 mV-5 mV/div - 1 Megaohm (When Using Passive Probe) & 50 ohms (DLM205x)
  • 500 MHz for 100 mV-100 V/div & 10 mV-500 mV/div - 1 Megaohm (When Using Passive Probe) & 50 ohms (DLM205x)
  • 8 kHz to 200 MHz - Cut-Off Frequencies

Function

  • Auto Setup Control
  • CAN Bus Signal Analysis
  • CAN FD Bus Signal
  • Computation & Analysis
  • FlexRay Bus Signal Analysis
  • I²C Bus Signal Analysis
  • LIN Bus Signal Analysis
  • Reference
  • Replay
  • Search
  • SENT Signal Analysis
  • Trend
  • UART Bus Signal Analysis
  • Zoom

Humidity

  • 55 ± 10 % Relative Humidity - Ambient Humidity

Input

  • ± 40 V - Input Range & Threshold Level Setting Range for Model 701988
  • ± 40 V (DC + AC Peak) - Max.
  • 150 Vrms - Max.
  • 28 Vrms - Max.
  • 300 mV Peak-to-Peak - Min. Input Voltage (701989)
  • 5 Vrms to 10 Vpeak - Max.
  • 500 mV Peak-to-Peak - Min. Input Voltage (701988)
  • Channel 1 to Channel 3 (When Using Logic Input) - Analog Input Channels (DLM20 x 4)
  • Channel 1 to Channel 4 - Analog Input Channels (DLM20 x 4)
  • Channel 1, Channel 2 - Analog Input Channels (DLM20 x 2)
  • Must Not Exceed 5 Vrms or 10 V Peak - Max.
  • Threshold ± 6 V - Input Range & Threshold Level Setting Range for Model 701989

Input Impedance

  • 1 Megaohm, ± 1 %, Approximately 20 PF - Analog Input
  • 50 ohms, ± 1 % (VSWR 1.4 or Less, DC to 500 MHz) - Analog Input
  • Approximately 100 kiloohms, 3 PF

Length

  • 4.40” (112 mm), Monochrome, Thermal - Built-in Printer

Measuring Time

  • 0.2 to 5,000 seconds - Max.
  • 100 milliseconds to 100 seconds - Accumulation Time

Operating Temperature

  • 5° to 40° C (41° to 104° F)

Output Noise

  • 0.05 Div RMS - Typical Residual Noise Level
  • 0.4 mV RMS - Residual Noise Level

Resolution

  • 0.01 microsecond
  • 0.05 V - Setting Resolution
  • 8-bits (25 LSB/div) - A/D Resolution
  • Maximum

Sample Rate

  • 62.5 KS/s to 1.25 GS/s
  • Maximum

Sensitivity

  • 2 mV/div-10 V/div (Steps of 1-2-5) - Voltage Axis Sensitivity Setting Range for 1 Megaohm
  • 2-500 mV/div (Steps of 1-2-5) - Voltage Axis Sensitivity Setting Range for 50 ohms

Supply Voltage

  • 10-240 Vac, 50/60 Hz
show more