Accuracy
- ± (1 % of Reading + 2-Digits) (50/60 Hz) - AC Voltage
- ± (1.2 % of Reading + 4-Digits), Beeps at below 30 ohms (Continunity Check) - Resistance
- ± (1.5 % of Reading + 4-Digits) - AC Current (50/60 Hz), AC Voltage (40 to 1,000 Hz)
- ± (2.0 % of Reading + 5-Digits) (40 to 1,000 Hz) - AC Current
- ≤ 3 (50/60 Hz) - Crest Factor
Approvals & Certifications
- EN 61010-2-031, EN 61010-2-32 (CAT. III 600 V)
Approvals & Certifications
Battery Life
- Approximately 200 Hours (Continuous)
Conductor Position Effect
Current
- 200 A - AC Current
- 600 A - AC Current
Diameter
- 1.18” (30 mm) - Diameter of Measurable Conductor
Display
- LCD (Digital Display: 1,999 Counts)
External Magnetic Field Effect
Humidity
- 45 to 90 % Relative Humidity or Less (Non-Condensing)
Operating Temperature
- -10° to 50° C (14° to 122° F)
Power Requirement
- 6F22 (006P) 9 V x 1
- 6LR61 x 2
Response Time
- Approximately 1 second (Approximately 2 seconds on Resistance Range)
Supply Voltage
- 200-600 V - AC Voltage
- 5.55 kVac for One Minute - Withstanding Voltage
- 600 Vrms or Less
Turn-Off Time
- Approximately 10 minutes - Auto Power-Off