Brand: Temposonics an Amphenol CompanyTemposonics sensors can be used in versatile mobile machines without any restriction and replace contact-based linear sensors like potentiometers.
Highly dynamic systems are controlled safely by means of Temposonics sensors, thus enhancing the productivity, availability and quality of the working process of the machine.
Insensitive to vibration, shocks, dust and weathering influence and electromagnetic disturbances.
Temposonics MH Series sensors are successfully used in front axle and articulated frame steering cylinders, hydraulic jacks and in steering systems for hydraulic units on agricultural and construction machinery.
Specifications
Approvals & Certifications
- ISO 9001 (DQS), 14982 Agricultural & Forest Machines
- SIL 2 Certification
- EN 61508, 50325-5: Bus-Protocol According to CiA DS-304 CANopen Safety, Device Profile DS-406 V3.1
- EMC EN 13309 Construction Machines, Immunity: ISO 11452-2 (200 V/m Antenna), ISO 11452-4 (200 mA BCI), Emissions: CISPR 25, Transiente Impulses: ISO 7637-1/2, E.S.D.: ISO /TR 10605
- IEC 61508
Communication
- Baud Rate: 50 to 1,000 Kbps
- CANopen
Consumption
- Current Consumption (12 Vdc): Typical ≤ 100 mA
- Current Consumption (24 Vdc): Typical ≤ 50 mA
Current
- Analog Inrush Current: Max.
- Digital Inrush Current: 1 A / 2 milliseconds - 12 Vdc
- Digital Inrush Current: 1.5 A / 2 milliseconds - 24 Vdc
Electrical Connectors
- M12
Electrical Protection
- Over Voltage Protection (Gnd-Vdc): up to 36 Vdc
- Polarity Protection Ground-Vdc: up to -36 Vdc
Enclosure, Body Material
- 303 Stainless Steel
Environmental Protection
- M12 Connector: EN 60529 (IP69K), Plugged
- Sensor Housing: EN 60529 (IP67)
Flange Material
- M12 Flange: Brass Nickel-Plated with O-Ring 13 x 1.6 NBR 70
Humidity
- EN 60068-2-30, 90 % Relative Humidity, Non-Condensing
Hysteresis
- ± 0.1 mm
Length
- Stroke Range: 1.9 to 98.4” (50 to 2,500 mm)
Linearity
- 2005 to 2500 mm: ≤ ± 0.8 mm
- 255 to 2,000 mm: ± 0.04 % of Full Scale
- 50 to 250 mm: ≤ ± 0.1 mm
Load
- Analog Load (Output mA): 235 to 265 ohms
- Analog Load (Output Vdc): > 10 kiloohms
Materials of Construction
- Flange (Ø 48 mm): 303 Stainless Steel 1.4305
- M12 Connector Insert Pins: Brass with Gold-Plated Pins
- M12 Connector Insert: Polyamide Reinforces
- Pressure Pipe (Ø 10 mm): 304L Stainless Steel 1.4306
Mounting Position
- Any Orientation
O-Ring Material
- Sealing O-Ring (40.87 x 3.53 mm), M12 Connector Insert (7 x 1.35 mm): NBR 80, 70
Operating Pressure
- psi: 5,076 (kPa: 35,000, bar: 350) Nominal
- psi: 6,527 (kPa: 45,000, bar: 450) - Max.
- psi: 9,065 (kPa: 62,500, bar: 625) Static
Operating Temperature
- Analog (Electronics): -40° to 105° C (-40° to 221° F)
- Digital (Electronics): -40° to 100° C (-40° to 212° F)
Output
- Analog: 0.5-4.5 Vdc
- Analog: 4-20 mA
Power
- Analog Power Drain: < 1 W
- Digital Power Drain: < 1.5 W
Process Temperature
- -40° to 105° C (-40° to 221° F)
Resolution
- Analog Typical, Digital (Position): 0.1 mm
- Digital: 1 mm/sec (Velocity)
Ring Material
- Back-Up Ring: 42.6 x 48 x 1.4 PTFE
Sample Rate
- Analog Internal Sample Rate: 2 milliseconds
- Digital Internal Sample Rate: 1 millisecond
Shock
- 50 G, 11 milliseconds at 1,000 Shocks Per Axis
- IEC 60068-2-27, 100 G, 6 milliseconds Single Shock
Storage Temperature
- -20° to 65° C (-4° to 149° F)
Supply Voltage
- 12 Vdc (8-32 Vdc)
- 24 Vdc (8-32 Vdc)
Temperature Range
- Digital Fluid: -30° to 85° C (-22° to 185° F)
Tolerance
- Analog Set Point Tolerance: ± 2 mm
- Digital Set Point Tolerance: ± 0.2 mm
Vibration
- IEC 60068-2-64, ɛ < ± 1.25 % of Full Scale for 20 G (r.m.s.) 10 to 2,000 Hz
Voltage
- Dielectric Strength: 500 Vdc (Ground-Vdc)
- Harsh Environment
- Mobile Applications