73202 Digital Multimeter

Brand: Yokogawa Electric Corporation

Digital multimeters (DMMs) employ an A/D converter with a dual-integration system, which determines the measurement value by converting the input voltage into time using an integration AD converter. 

The interval to perform an integral action periodically is referred to as the integral action time.
Features
  • Compact size, ideal for carrying
  • Large display for easy viewing
  • Safe design allows measurement in excess of 20 A (excluding 73204)
  • Special model for voltage measurement (73204)
  • Simple auto hold function
  • Capacitors can be checked (73202/73203)

Specifications

Accuracy

  • ± (0.5 % of Reading + 1-Digit) - DC Voltage Measurement
  • ± (1 % of Reading + 1-Digit) (Testing Current 1 mA or Less) - Diode Test
  • ± (1 % of Reading + 5-Digits) - AC Voltage Measurement
  • ± (2 % of Reading + 2-Digits) - DC Current Measurement
  • ± (2 % of Reading + 5-Digits), Typical (20 NF Range: Accuracy after Zero Calibration) - Capacitor Check
  • ± (2.5 % of Reading + 20-Digits) - AC Current Measurement
  • ± (5 % of Reading + 2-Digits) - Resistance Measurement

Battery Life

  • Approximately 600 Hours (For Continuous DC Voltage Measurement with Alkaline Cells)

Current

  • < 1 mA - Max.
  • DC Current & AC Current Measurement: 400 µA - 10 A

Display

  • Digital Display - 4,300-Count Digital Reading at Measuring Rate 2 times/second

Function

  • Auto Hold
  • Auto Power Off
  • Overvoltage & Current Warning

Humidity

  • 70 % Relative Humidity or Less at [40° to 50° C (104° to 122° F)] Operating Temperature (Non-Condensing)
  • 80 % Relative Humidity or Less at [0° to 40° C (0° to 104° F)] Operating Temperature (Non-Condensing)

Input

  • 10 A - (15 A / 600 V Fuse-Protected) - Max.
  • 400 mA - (500 mA / 600 V Fuse-Protected) - Max.
  • 500 mA / 250 V Fuse-Protected - Input Protection for Capacitor Check
  • 600 V - Max.
  • 600 Vrms - Max.

Operating Temperature

  • 0° to 50° C (32° to 122° F)

Power Supply

  • 2 AAA (LR03 or R03) Dry Cells

Resistance

  • > 100 megaohms - Input Resistance for DC Voltage
  • > 11 megaohms, 11 megaohms, 11 megaohms, 11 megaohms, < 50 PF - Input Resistance for AC Voltage

Response Time

  • 0.2 seconds or Less (Buzzer Response) - Continuity Check
  • 1 seconds or Less - DC Voltage & DC Current Measurement, Resistance Measurement (400 kiloohms or Less) & Diode Test, Capacitor Check
  • 1.5 seconds or Less for 400 mV Range - DC Voltage Measurement
  • 15 seconds or Less for 40 megaohms Range - Resistance Measurement
  • 2 seconds or Less - AC Voltage & AC Current Measurement
  • 5 seconds or Less for 4 megaohms Range - Resistance Measurement

Storage Temperature

  • -20° to 60° C (-4° to 140° F)

Supply Voltage

  • < 0.7 V - Open-Circuit Voltage for Resistance Measurement
  • < 1.0 V - Open-Circuit Voltage for Resistance Measurement
  • < 3.4 V - Open-Circuit Voltage for Resistance Measurement, Continuity Check, Diode Test
  • 3.7 kVac for 1 Minute (Between Input Terminals & Casing) - Withstanding Voltage
  • DC Current & AC Current Measurement: 400 mV - 600 V

Voltage Drop

  • < 0.04 V/A - DC Current & AC Current Measurement
  • < 0.17 mV/µA - DC Current & AC Current Measurement
  • < 3 mV/mA - DC Current & AC Current Measurement
show more