Model NC230 Ao/CC-Link Converter

Brand: Yokogawa Electric Corporation

The Model NC230 Ao/CC-Link converter receives input of digital values (0 to 10,000) from MELSEC (Mitsubishi Electric Corporation’s sequencer) via the CC-Link, and converts them to 16 (1-5 Vdc) Analog output signals.

The Analog output signals can be coupled with Yokogawa M&C’s signal converter - the JUXTA D Series – via a dedicated cable.

The NC230 is designed for either wall mounting or DIN-rail mounting.

1 model matching criteria
  • Power Supply - 100-240 Vac (-15%, 10%), 50/60 Hz
  • Type - Instrument with 16-Point Analog Output Writing Configuration Profile
4 In Stock
$91.00CAD
Does not ship to Washington, United States

Specifications

Accuracy

  • ± 0.1 % of Full Scale

Ambient Temperature Range

  • 0° to 50° C (32° to 122° F)

Channels

  • 4 - Stations Occupied

Communication

  • Baud Rate: 156 Kbps, 625 Kbps, 2.5 Mbps, 5 Mbps or 10 Mbps

Connection Pin-Out

  • 14-Pin Plug-In Converter

Consumption

  • Approximately 3.7 VA at (100 Vac)
  • Approximately 5.8 VA at (240 Vac)

Distance

  • 0 to 1,969 feet (0 to 600 metres): with Transmission Speed 625 Kbps
  • 0 to 3,937 feet (0 to 1,200 metres): with Transmission Speed 156 Kbps
  • 0 to 328.1 feet (0 to 100 metres): with Transmission Speed 10 Mbps
  • 0 to 492.1 feet (0 to 150 metres): with Transmission Speed 5 Mbps
  • 0 to 656.2 feet (0 to 200 metres): with Transmission Speed 2.5 Mbps

Enclosure, Body Material

  • ABS Resin

Humidity

  • 5 to 90 % Relative Humidity, Non-Condensing - Normal Operating Conditions
  • 5 to 95 % Relative Humidity, Non-Condensing - Transport/Storage Conditions

Indication

  • LED Indicator - RDY, RUN, ERR, SD & RD

Insulation Resistance

  • 100 megaohms Min. at 500 Vdc between Any Two Terminals

Mounting

  • DIN Rail Mounting
  • Wall Mounted

Output

  • Configration: 1-5 V Analog Output

Output Cycle

  • Approximately 250 milliseconds / 16 Outputs

Power Supply

  • 100-240 Vac (-15 %, 10 %), 50/60 Hz

Power Supply Effect

  • ± 0.1 % of Full Scale, Max.

Storage Temperature

  • -40° to 70° C (-40° to 158° F)

Supply Voltage

  • 1,000 Vac/minute - Withstand Voltage between Output & CC-Link Output Terminals
  • 100-120 Vac
  • 2,000 Vac/minute - Withstand Voltage between Any Two Terminals, Among Terminals, Power Supply & Grounding Terminals

Switch Type

  • Rotary Switches - 1 to 61 Remote Station Number Setting

Temperature Change

  • 10° C (18° F)/hr, Max.

Temperature Effect

  • ± 0.2 % of Full Scale, Max.

show more