EJA110E Differential Pressure Transmitter

Brand: Yokogawa Electric Corporation

The high performance differential pressure transmitter EJA110E features single crystal silicon resonant sensor and is suitable to measure liquid, gas, or steam flow as well as liquid level, density and pressure.

EJA110E outputs a 4-20 mA DC signal corresponding to the measured differential pressure. Its accurate and stable sensor can also measure the static pressure which can be shown on the integral indicator or remotely monitored via BRAIN or HART communications.

Other key features include quick response, remote set-up using communications and self-diagnostics.

FOUNDATION Fieldbus, PROFIBUS PA and 1-5 Vdc with HART (Low Power) protocol types are also available.

All EJA-E series models in their standard configuration, with the exception of the Fieldbus, PROFIBUS and Low Power types, are certified as complying with SIL 2 for safety requirement.

Output

Output

Measurement Span

Measurement Span

Wetted Material

Wetted Material

Process Connection

Process Connection

Bolt & Nut Material

Bolt & Nut Material

Installation

Installation

Amplifier Housing

Amplifier Housing
  • view details
  • view details

Electrical Connection

Electrical Connection
  • view details
  • view details
  • view details

Integral Indicator

Integral Indicator

Mounting

Mounting

FM Approval

FM Approval

ATEX Approval

ATEX Approval
  • view details
  • view details

CSA Approval

CSA Approval
  • view details
  • view details

IECEx Approval

IECEx Approval
  • view details

Accuracy

Accuracy

Working Pressure

Working Pressure

Painting

Painting

Exterior Parts

Exterior Parts
  • view details

O-Ring

O-Ring

Lightning Protection

Lightning Protection
  • view details

Oil-Prohibited Use

Oil-Prohibited Use
  • view details
  • view details
  • view details
  • view details

Fill Fluid

Fill Fluid
  • view details

Calibration Unit

Calibration Unit

Vent Size

Vent Size

Gasket Material

Gasket Material

Plating

Plating
  • view details

Output Limits & Failure Operation

Output Limits & Failure Operation
  • view details
  • view details
  • view details

Body Configuration

Body Configuration
  • view details
  • view details

Tag Plate

Tag Plate

Data Configuration

Data Configuration

European Pressure Equipment Directive

European Pressure Equipment Directive
  • view details

Material Certificate

Material Certificate

Pressure Test / Leak Test Certificate

Pressure Test / Leak Test Certificate
  • view details
  • view details
View Details
Part Number / SKU

EJA110E-DFS5J-912NB

  • Output

    4-20 mA DC with Digital Communication, BRAIN Protocol

  • Measurement Span

    0.5 to 5 kPa (2.0 to 20 inches WC)

  • Wetted Material

    Wetted Materials 1

  • Process Connection

    Without Process Connector (1/4” NPT Female on the Cover Flanges)

  • Bolt & Nut Material

    B7 Carbon Steel

  • Installation

    Horizontal Piping & Left Side High Pressure

  • Amplifier Housing

    Cast Aluminum Alloy

  • Electrical Connection

    1/2” Female NPT, Two Electrical Connections without Blind Plugs

  • Integral Indicator

    No Integral Indicator

  • Mounting

    304 Stainless Steel 2” Pipe Mounting, Flat Type (For Horizontal Piping)

  • FM Approval

    Without FM Approval

  • ATEX Approval

    Without ATEX Approval

  • CSA Approval

    Without CSA Approval

  • IECEx Approval

    Without IECEx Approval

  • Accuracy

    Standard Accuracy

  • Working Pressure

    16 MPa

  • Painting

    Deep Sea Moss Green Paint (Munsell 0.6GY3.1/2.0 or its Equivalent)

  • Exterior Parts

    Standard Materials

  • O-Ring

    Buna-N O-Ring

  • Lightning Protection

    Without Lightning Protection

  • Oil-Prohibited Use

    No Oil-Prohibited Use

  • Fill Fluid

    Silicone Fill Fluid

  • Calibration Unit

    kPa Calibration (kPa Unit)

  • Vent Size

    Standard Length: 34 mm

  • Gasket Material

    PTFE Teflon

  • Plating

    No Plating on Diaphragms

  • Output Limits & Failure Operation

    No Output Limits & Failure Operation

  • Body Configuration

    No Body Configuration

  • Tag Plate

    Without Tag Plate

  • Data Configuration

    Without Data Configuration

  • European Pressure Equipment Directive

    Without European Pressure Equipment Directive

  • Material Certificate

    Without Cover Flange

  • Pressure Test / Leak Test Certificate

    Without Pressure Test / Leak Test Certificate

Specifications

Accuracy

  • ± (0.002 + 0.0019 URL/Span) % of Span Includes Terminal-based Linearity, Hysteresis & Repeatability, - Capsule M (High Accuracy)
  • ± (0.005 + 0.0013 URL/Span) % of Span Includes Terminal-based Linearity, Hysteresis & Repeatability, - Capsule V (High Accuracy)
  • ± (0.005 + 0.0025 URL/Span) % of Span Includes Terminal-based Linearity, Hysteresis & Repeatability, - Capsule M
  • ± (0.005 + 0.0049 URL/Span) % of Span Includes Terminal-based Linearity, Hysteresis & Repeatability, - Capsule H (High Accuracy)
  • ± (0.005 + 0.005 URL/Span) % of Span Includes Terminal-based Linearity, Hysteresis & Repeatability, - Capsule V
  • ± (0.005 + 0.01 URL/Span) % of Span Includes Terminal-based Linearity, Hysteresis & Repeatability, - Capsule H
  • ± (0.005 + 0.02 URL/Span) % of Span Includes Terminal-based Linearity, Hysteresis & Repeatability, - Capsule F
  • ± 0.04 % of Span Includes Terminal-based Linearity, Hysteresis & Repeatability, - for Higher Accuracy
  • ± 0.055 % of Span Includes Terminal-based Linearity, Hysteresis & Repeatability,

Alarm

  • Down-Scale: -5 %, 0.8 Vdc or Less - for 1-5 V HART
  • Down-Scale: -5 %, 3.2 mA DC or Less - for 4-20 mA HART/BRAIN
  • Up-Scale: 110 %, 21.6 mA DC or more - for 4-20 mA HART/BRAIN
  • Up-Scale: 110 %, 5.4 Vdc or more - for 1-5 V HART

Ambient Temperature Range

  • -30° to 80° C (-22° to 176° F) - with LCD Display
  • -40° to 85° C (-40° to 185° F)

Approvals & Certifications

  • Leak Test
  • Material Certificate
  • Pressure Test
  • SIL 2 Capability for Single Transmitter Use, SIL 3 Capability for Dual Transmitter Use, IEC 61508: 2000

Approvals & Certifications

  • ATEX Flameproof & Intrinsically Safe
  • CE
  • CSA Explosion-proof & Intrinsically Safe
  • EMC EN 61326-1 Class A, EN 61326-2-3, EN 61326-2-5
  • FM Explosion-proof & Intrinsically Safe
  • IECEx Intrinsically Safe & Flameproof Approval
  • NAMUR NE43
  • PED 2014/68/EU, 97/23/EC

BSP Connection

  • 1/2" BSPT Female
  • 1/4" BSPT Female

Burst Pressure

  • psi: 10,000 (MPa: 69, bar: 690)
  • psi: 6,800 (MPa: 47, bar: 470)

Cable Material

  • Polyethylene Insulated PVC Sheathed

Communication

  • BRAIN
  • FOUNDATION Fieldbus
  • HART
  • PROFIBUS PA

Consumption

  • 0.96-3 mA - Power Consumption for 1-5 V HART
  • 27 mW - Power Consumption for 1-5 V HART

Damping Adjustment

  • 0 to 100 seconds

Diaphragm Material

  • Hastelloy C-276

Display

  • 10-Segment - User Configurable, Signal Characterizer
  • 5-Digit Numerical Display
  • 6-Digit Unit Display
  • Bar Graph
  • LCD Display

Distance

  • 0 to 2 Kilometers (1.25 Miles) - Communication Distance

Drain, Vent Valves & Plug

  • 316 Stainless Steel
  • Hastelloy C-276
  • Monel
  • Super Duplex Stainless Steel

Electrical Connectors

  • 1/2" NPT Female
  • G 1/2" Female
  • M20 Female

Electrical Protection

  • Lightning Protection

Enclosure Finish

  • Deep Sea Moss Green Paint (Munsell 0.6 GY3.1/2.0 or its Equivalent)
  • Polyurethane Paint

Enclosure, Body Material

  • ASTM CF-8M Stainless Steel
  • Low Copper Cast Aluminum Alloy

Environmental Protection

  • IP66
  • IP67
  • NEMA 4X

Fill Material

  • Fluorinated Oil
  • Silicone

Flange Material

  • ASTM CF-8M
  • Hastelloy C-276
  • Monel
  • Super Duplex Stainless Steel

Fluid

  • Liquid & Gas
  • Steam

Gasket Material

  • Fluorinated Rubber - Process Connector Gasket
  • PTFE Teflon - Process Connector Gasket
  • Teflon-Coated 316L Stainless Steel

Humidity

  • 0 to 100 % RH - Ambient Humidity

Input Impedance

  • 10 kΩ or more at 2.4 kHz

Length

  • 1.33" (34 mm) Standard - Long Vent
  • 4.6" (119 mm) Total Length - Long Vent

Load

  • 0 to 1,290 ohms - for Operation
  • 0.22 μF or Less - Load Capacitance
  • 250 to 600 ohms - for Digital Communication
  • 3.3 MH or Less - Load Inductance

Materials of Construction

  • 316 Stainless Steel - Name Plate & Tag

Mounting Position Effect

  • Tilting up to 90° will cause Zero Shift up to 0.4 kPa

NACE & NIST

  • NACE MR-0103

NPT Connection

  • 1/2" NPT Female
  • 1/4" NPT Female

Nut & Bolt Material

  • 316L Stainless Steel
  • 660 Stainless Steel
  • B7 Carbon Steel

O-Ring Material

  • Buna-N - Cover O-Ring
  • Fluororubber - Cover O-Ring

Operating Temperature

  • -20° to 80° C (-4° to 176° F) - for Oil-Prohibited Use

Output

  • 0.9-5.4 Vdc
  • 1-5 Vdc
  • 2-Wire 4-20 mA DC
  • 3.6 - 21.6 mA

Output Load

  • 1 MΩ or greater - Meter Input Impedance for 1-5 V HART

Overpressure Effect

  • ± 0.03 % of URL up to psi: 2,300 (MPa: 16, bar: 160) - Capsules M, H, V

Power Requirement

  • 9-28 Vdc - for General Use & Flameproof Typical

Power Supply Effect

  • ± 0.005 % per Volt (From 21.6 - 32 Vdc, 350 ohms)

Pressure Range

  • inH₂O: -2,000 to 2,000
  • kPa: -500 to 14,000
  • mbar: -5,000 to 140,000
  • mmH₂O: -10,000 to 10,000
  • psi: -72.52 to 2,031

Pressure Type

  • Absolute
  • Differential
  • Gauge

Process Connection Material

  • ASTM CF-8M
  • Hastelloy C-276
  • Monel
  • Super Duplex Stainless Steel

Process Temperature

  • -40° to 120° C (-40° to 248° F)

Response Time

  • 150 ms
  • 90 ms

Span - Minimum

  • psi: 73 (MPa: 0.5, bar: 5)

Stability

  • ± 0.1 % of URL Per 7-Years - for M, H & V Capsules
  • ± 0.2 % of URL Per 1-year - for F Capsule

Static Pressure Effect

  • ± (0.04 % of Span + 0.208 % of URL) for F Capsule - Effect on Zero
  • ± 0.028 % of URL Per psi: 1,000 (MPa: 6.9, bar: 69) for M, H, V Capsule - Effect on Zero
  • ± 0.1 % of Span Per psi: 1,000 (MPa: 6.9, bar: 69) for F, M, H & V Capsules - Span Effects

Supply Pressure - Maximum

  • psi: 2,300 (MPa: 16, bar: 160) - Silicone Oil
  • psi: 3,600 (MPa: 25, bar: 250) - High Pressure-Proof for Silicone Oil

Supply Voltage

  • 10.5-30 Vdc - for Intrinsically Safe, Typical N, Non-Incendive
  • 10.5-32 Vdc - for Lightning Protector
  • 10.5-42 Vdc - for General Use & Flameproof Typical
  • 16.6 Vdc - for Digital Communications, BRAIN & HART
  • 24 Vdc, up to A 550 ohms Load

Temperature Effect

  • ± [0.07 % of Span + 0.015 % of URL] Per 28° C (50° F) - Capsule H Ambient Temperature Effect
  • ± [0.07 % of Span + 0.02 % of URL] Per 28° C (50° F) - Capsule M Ambient Temperature Effect
  • ± [0.07 % of Span + 0.03 % of URL] Per 28° C (50° F) - Capsule V Ambient Temperature Effect
  • ± [0.08 % of Span + 0.18 % of URL] Per 28° C (50° F) - Capsule F Ambient Temperature Effect

Update Time

  • 360 ms - Static Pressure
  • 45 ms - Differential Pressure

Wetted Materials

  • 316L Stainless Steel - Capsule
  • F316L Stainless Steel - Capsule
  • Hastelloy C-276 - Capsule
  • Monel - Capsule
  • Tantalum - Capsule

Zero Offset

  • External Zero is Continuously Adjustable with 0.01 % Incremental Resolution of Span
show more