AQ1200 Optical Time Domain Reflectometer Module

Brand: Yokogawa Electric Corporation

The AQ1200 Multi Field Tester OTDR is a compact and lightweight handheld OTDR optimized for the installation and maintenance of optical fiber cables. 

Designed with ease of use in mind to simplify field testing, improve work efficiency and ensure qualify results. 

Seven models are offered, each with unique wavelength(s) based on their specific application.

Specifications

Accuracy

  • Loss Measurement Accuracy: ± 0.05 dB
  • Loss Measurement Accuracy: ± 0.05 dB/dB

Approvals & Certifications

  • AS
  • BS
  • BSMI
  • CSA
  • EK
  • EMC (Emissions): EN 61326-1 Class A, EN 55011 Class A, Group 1
  • EMC (Immunity): EN 61326-1 Table 2 (For Industrial Locations)
  • IEC 60825-1: 2007 (Class I, M), 60825-1: 2014 (Class I,) - Laser Safety
  • UL
  • VDE

Battery Life

  • Recharge Time: 5 Hours
  • Run Time: 6 Hours

Connectors

  • Optical Connector: 2.5 mm Ferrule Typical
  • Optical Connector: Universal Adapter SC, FC

Display

  • 5.7” TFT Color LCD
  • 640 x 480 Pixels - (0.002 % or Fewer of All Displayed Pixels Including RGB)
  • Resolution: 1024 x 768 Pixels or Better

Distance

  • 1,640 to 1,679,790 feet (0.5 to 512 Kilometers)

Frequency

  • Modulation Mode: 270 to 2,000 Hz

Function

  • Analysis
  • Distance Measurement
  • Loss Measurement
  • PC Remote Control
  • Ping Test
  • Return Loss Measurement

Humidity

  • 20 to 85 % Relative Humidity, Non-Condensing

Interface Connection

  • Ethernet - 10Base T/100Base Transmitter
  • USB (USB1.1 Typical A & Typical B, Typical B (Mini))

Operating Temperature

  • 0° to 35° C (32° to 95° F) - when Battery is being Charged
  • 0° to 40° C (32° to 104° F) - when AC Adapter is being Used
  • 0° to 45° C (32° to 113° F)

Output

  • -3 ± 1 dBm - Optical Output Level

Output Noise

  • 0.5 NW (-63 dBm, 1,310 Nm) - Noise Level (Standard, PON)
  • 50 NW (-43 dBm, 1,310 Nm) - Noise Level (High Power)
  • 50 NW (-43 dBm, 1,550 Nm) - Noise Level (PON)

Port

  • 2 Ports - Optical Port (AQ1200A, AQ1200B, AQ1200C, AQ1200E, AQ1205A, AQ1205E, AQ1205F)
  • 3 Ports - Optical Port (AQ1200E, AQ1205E, AQ1205F)

Power

  • 10 to -70 dBm - Standard, PON
  • 24 to -50 dBm - High Power
  • 27 to -50 dBm - High Power, PON
  • 7 to -60 dBm - Standard

Power Requirement

  • 100-240 Vac, 50/60 Hz

Pulse Range

  • 3 to 20,000 Nanoseconds - Pulse Width

Range

  • Typical Dynamic Range: 33 dB (AQ1200B)
  • Typical Dynamic Range: 34 dB (AQ1200C)
  • Typical Dynamic Range: 34/32 dB (AQ1200A)
  • Typical Dynamic Range: 38/36, 36 dB (AQ1200E)
  • Typical Dynamic Range: 42/40 dB (AQ1205A)
  • Typical Dynamic Range: 42/40, 37 dB (AQ1205F)
  • Typical Dynamic Range: 42/40, 38 dB (AQ1205E)

Resolution

  • 0.001 dB Min. - Readout Resolution (Vertical Axis Parameters)
  • 0.01 - Readout Resolution
  • 0.394” (1 cm) Min. - Readout Resolution (Horizontal Axis Parameters)

Stability

  • ± 0.05 dB - Level Stability (AQ1200A)
  • ± 0.15 dB - Level Stability (AQ1200B, AQ1200C)

Storage Temperature

  • -20° to 60° C (-4° to 140° F)

System Requirements

  • Microsoft Excel 2000 or Later
  • Windows® 2000/XP/7/Vista Operating System

Uncertainty

  • PON Power Meter: ± 0.5 dB
  • Standard & High Power Optical Power Meter: ± 5.0 %

Wavelength

  • 1,625 ± 10 Nm - Measured Wavelength for AQ1200B, AQ1200E
  • 1,650 ± 10 Nm - Measured Wavelength for AQ1200C, AQ1205F
  • 650 ± 20 Nm - Center Wavelength
  • Typical 1,310 / 1,550 ± 20 Nm - Measured Wavelength for AQ1200A, AQ1200E, AQ1205A, AQ1205E, AQ1205F
  • Typical 1,625 ± 20 Nm - Measured Wavelength for AQ1205E
  • Typical 1,650 ± 5 Nm - Measured Wavelength for AQ1200C, AQ1205F
show more