AXFA11G Magnetic Flow Converter
Brand: Yokogawa Electric CorporationThe AXFA11 magnetic converter retains all the features and functions of the ADMAG series of converters, featuring Yokogawa’s enhanced dual frequency excitation method as an option for difficult applications as well as new diagnostics to detect electrode coating.
Combined with a flow tube utilizing the optional replaceable electrode design, the user can schedule maintenance for reduced process downtime and in turn a lower total cost of ownership.
The AXFA11 can be combined with AXG and AXW flow meters for specific specifications.
Its wall-mounted design for general purpose applications can also be used as a universal converter for third-party flow tubes.
Features- User-oriented Functionality
- Fluid Adhesion Level Diagnosis
- Clear and Versatile Indications
- “Easy Setup” Parameters
- Operation Immediately after Installation
- Compact and Light-weight Converter
- Expansion of Product Lineup
- Improve Accuracy Specification
- Enhanced Performance and Specifications
- Enhanced Dual Frequency Excitation Method
- Improved Minimum Conductivity
- High-Speed Pulse Output
- Versatile Input/output Function
Specifications
Accuracy
- ± 0.2 % of Rate
- ± 0.35 % of Rate
- 0.18 % of Rate + 0.2 mm/sec
- 0.2 % of Reading - High Accuracy Calibration
- 0.35 % of Reading
- Pulse Output Accuracy Plus ± 0.05 % of Span - Current Output
Alarm
- 2.4 mA or Less
- Fixed to 4 mA, 21.6 mA or more
Ambient Temperature Range
- -40° to 60° C (-40° to 140° F)
Approvals & Certifications
- EMC EN 61326-1 Class A, EN 61326-2-3, EN 61000-3-2 Class A, EN 61000-3-3
Cable Material
- Polyethylene Insulated PVC Sheathed
Communication
- BRAIN
- HART
Consumption
- 20 W - Max.
Cover Material
- Aluminum Alloy - Converter Material
Damping Adjustment
- 0.1 to 200 seconds
- 3 seconds - Default
Diagnostics
- System, Process, Setting Alarms & Warnings
Display
- Full Dot-Matrix LCD
Distance
- 6” (15 cm) or more - Distance from Power Line
- Up to 1.5 Kilometers - Communication Distance (BRAIN)
Electrical Connectors
- ANSI 1/2” NPT Female
- ISO M20 x 1.5 Female
- JIS G 1/2” Female
- M4 Screw Terminal
Electrical Protection
- Lightning Protection
Enclosure Finish
- Corrosion-Resistant Coating
- Mint Green (Munsell 5.6BG 3.3/2.9 or its Equivalent)
- Silver Gray (Munsell 3.2PB 7.4/1.2 or its Equivalent)
Enclosure, Body Material
- Aluminum Alloy - Converter Material
Environmental Protection
- IP66
- IP67
Humidity
- 0 to 100 % - Ambient Humidity
Input Impedance
- 10 kiloohms or more at 2.4 kHz
Insulation Resistance
- 100 megaohms at 500 Vdc - between Power Supply Terminals & Ground Terminal, between Power Supply Terminals & Input/Output / Excitation Current Terminals
- 20 megaohms at 100 Vdc - between Ground Terminal & Input/Output/Excitation Current Terminals, between Input/Output/Excitation Current Terminal
Load
- 0.22 µF or Less - Load Capacitance
- 3.3 MH or Less - Load Inductance
Materials of Construction
- Ceramics Lining
- EPDM Rubber Lining
- Natural Soft Rubber Lining
- PFA Lining
- Polyurethane Rubber Lining
Mounting
- 2” Pipe Mount
- Panel Mount
- Surface Mount
Operating Temperature
- -20° to 60° C (-4° to 140° F) - Indicator's Operating Range
Operating Voltages
- 20.4-28.8 Vac
- 20.4-28.8 Vdc
- 80-264 Vac
- 90-130 Vdc
Output
- 30 Vdc (OFF) / 200 mA (ON) - One Pulse, One Alarm, Two Status Outputs
- 4-20 mA DC (Load Resistance: 1 kiloohms, Max.
- Pulse Signals
Power Supply
- 100-120 Vdc - Rated Power Supply
- 100-240 Vac, 50/60 Hz - Rated Power Supply
- 24 Vac, 50/60 Hz - Rated Power Supply
- 24 Vdc - Rated Power Supply
Pulse Range
- 0.0001 to 10,000 Pulse/second - Output Rate
- 0.05 to 100 milliseconds - Pulse Width
Repeatability
- ± 0.1 % of Rate (V≥ 1 m/sec (3.3 ft/sec))
- 0.05 % of Rate ± 0.5 mm/sec (V< 1 m/sec (3.3 ft/sec))
Resistance
- 10 ohms or Less - with Lightning Protector
- 100 kiloohms or more (OFF) - Load Resistance
- 100 ohms or Less - Grounding Resistance
- 200 ohms or Less (ON) - Load Resistance
- 250 to 450 ohms (Including Cable Resistance) - Load Resistance for BRAIN Communication
- 250 to 600 ohms (Including Cable Resistance) - Load Resistance for HART Communication
Supply Voltage
- 1,400 Vac for 2 seconds between Power Supply Terminals & Ground Terminal, between Power Supply Terminals & Input/Output Terminals - Withstand Voltage
- 160 Vac for 2 seconds between Excitation Current Terminal & Ground Terminal - Withstand Voltage
- 350 Vac for 2 seconds between Excitation Current Terminal & Input/Output Terminals - Withstand Voltage
Vibration
- 4.9 m/sec² or Less (Frequency of 500 Hz or Less) in Conformity with IEC 60068-2-6
Documentation
Product Manuals
- Instruction Manual A pdf 6.9 MB
- Instruction Manual B pdf 876 KB
- Instruction Manual C pdf 1.4 MB
- Instruction Manual D pdf 791 KB
- Instruction Manual E pdf 5.3 MB
- Instruction Manual F pdf 10.7 MB
- Instruction Manual G pdf 532 KB
- Instruction Manual H pdf 547 KB
- Instruction Manual I pdf 1.0 MB
- Instruction Manual J pdf 100 KB