GM10 Data Acquisition Module

Brand: Yokogawa Electric Corporation

The Modular GM10 is a product to the Yokogawa SMARTDAC+ Data Acquisition and Control product line.

The SMARTDAC+ is a fresh approach to data acquisition and control, with smart and simple touch operation as a design priority.

Through smart architecture, the GM10 enables a scalable data acquisition system.

Scalability:
  • Up to 420 channels per system
  • Plug and lock modules
Ease of Use:
  • Web-based configuration
  • Live web-based data viewing
Mobile Connectivity:
  • Bluetooth
  • Mobile application
Reliability:
  • Secure data storage
  • High accuracy measurement
  • Automatic backfill function (GA10 data logging software)
Noise Tolerance:
  • Electromagnetic relay module
Features
  • Modular housing for up to 10 I/O modules per GM10 unit
  • Measurement capability of up to 420 actual input channels in a multi-unit configuration
  • Internal memory of up to 1.2 GB
  • Installation flexibility (no attachments required)
  • Open front panel for easy insertion or removal of modules
  • 4 alarms per measurement channel: high limit, low limit, difference high limit, difference low limit, rate of change increase, rate of change decrease, delay high, delay low

Specifications

Alarm

  • High Limit
  • Low Limit

Ambient Temperature Range

  • -20° to 60° C (-4° to 140° F)

Approvals & Certifications

  • R & TTE Directive - EN 61010-1, EN 61010-2-030, EN 62311

Approvals & Certifications

  • CE
  • CSA 22.2 No 61010-1, CSA 22.2 No.61010-2-030-12
  • EMC Directive: EN 61326-1 Class A Table 2, EN 61000-3-2, EN 61000-3-3, EN 55011 Class A Group 1
  • GOST
  • KC
  • LVD: EN 61010-1, EN 61010-2-030
  • NRTL
  • RCM: AS/NZS4268, AS/NZS2772.2
  • UL 61010-1, UL 61010-2-030 (CSA NRTL/C)
  • WEEE Directive Support

Channels

  • 100 - Number of mATH Channels

Communication

  • ARP
  • Bluetooth - SPP
  • DARWIN
  • DHCP
  • EIA RS-422 / RS-485
  • Ethernet IEEE 802.3
  • Ethernet TCP/IP
  • FTP
  • HTTP
  • ICMP
  • IP
  • Modbus
  • Modbus RTU
  • Modbus TCP/IP
  • SMTP
  • SNTP
  • SSL
  • TCP
  • UDP
  • USB 2.0

Display

  • 7-Segment LED

Frequency

  • 50/60 Hz ± 1 %

Humidity

  • 20 to 85 % Relative Humidity, Non-Condensing
  • 55 ± 10 % Relative Humidity, 23 ± 2° C (73.4 ± 3.6° F) - General Operating Condition

Input

  • 0.32 to 5.2 V to Standard Signal
  • 0-20 mA DC
  • -200 mV to 50 V - DCV
  • 4-20 mA DC - Standard Signal

Insulation Resistance

  • 20 megaohms or Greater at 500 Vdc between RS-422/485/Ethernet Terminals & Internal Circuitry

Measurement Accuracy

  • DCV: ± (0.01 % of Reading + 2 mV) - 6 V (1-5 V)
  • DCV: ± (0.01 % of Reading + 5 μV) - 20 mV
  • ± [0.02 % of Reading + 0.16° C (0.288° F)] - Pt100 (High Resolution)
  • ± [0.02 % of Reading + 0.2° C (0.36° F)] - Pt100
  • ± 0.2° C (± 0.36° F), However, -200° to 0° C (-328° to 0° F): ± [0.10 % of Reading + 0.2° C (0.36° F)] - T Thermocouple
  • ± 0.2° C (± 0.36° F), However, -200° to 0° C (-328° to 0° F): ± [0.15 % of Reading + 0.2° C (0.36° F)] - K Thermocouple [-200° to 500° C (-328° to 932° F)]
  • ± 1.1° C (± 1.98° F) - R Thermocouple

Measuring Time

  • 500 milliseconds to 30 seconds - Communication Interval

Mounting

  • Desktop
  • DIN Rail
  • Wall Mounted

Operating Temperature

  • -20° to 60° C (-4° to 140° F)

Range

  • Approximately 32 feet (10 metres) - Bluetooth Communication

RFI/EMI Effect

  • 400 A/m or Less (DC & 50/60 Hz) - Magnetic Field

RTD Type

  • Cu10
  • Cu100
  • Cu25
  • Cu50
  • Cu53
  • JPt100
  • Ni100
  • Ni120
  • Pt100
  • Pt200
  • Pt25
  • Pt46
  • Pt50

Sensor, Probe Type

  • B Thermocouple
  • E Thermocouple
  • J Thermocouple
  • K Thermocouple
  • L Thermocouple
  • N Thermocouple
  • RTD
  • R Thermocouple
  • S Thermocouple
  • T Thermocouple
  • U Thermocouple
  • W Thermocouple

Shock

  • When Off, 500 m/sec² or Less, Approximately 10 milliseconds, 3 times in 6 Directions (± X, ± Y, ± Z)
  • When On, 98 m/sec² or Less, 11 milliseconds, 3 times in 6 Directions (± X, ± Y, ± Z)

Supply Voltage

  • 180-264 Vac
  • 90-132 Vac

Temperature Range

  • -200° to 850° C (-328° to 1,562° F) - RTD
  • -270° to 2,320° C (-454° to 4,208° F) - Thermocouple

Update Time

  • 30 minutes - Warmup

Vibration

  • 5 ≤ F < 8.4 Hz Amplitude 3.5 mm Peak
  • 8.4 ≤ F ≤ 160 Hz Acceleration 9.8 m/sec²
show more