YPP6300 Pulse Input Flow Rate/Totalizer
Brand: Yokogawa Electric CorporationThe YPP6300 PROPLUS meters are 1/8" DIN flow rate/ totalizers specifically designed for displaying flow rate and total from flowmeters with Analog or pulse outputs.
These flow rate/totalizers are particularly well-suited for flow applications because they can display flow rate and flow total at the same time, provide power to drive the flowmeter, and display flow total, flow grand total, or non-resettable flow total on up to nine digits.
Features- Pulse, Open Collector, NPN, PNP, TTL, Switch Contact, Sine Wave (Coil), Square Wave Inputs
- Gate Function for Rate Display of Slow Pulse Rates
- Rate Displayed as Units per Second, Minute, Hour, or Day
- Total, Grand Total or Non-Resettable Grand Total
- 9-Digit Totalizer with Total Overflow Feature
- K-Factor Calibration or Scale with up to 32-Point Linearization
- Isolated 24 VDC @ 200 mA Transmitter Power Supply
- Large Dual-Line 6-Digit Display, 0.60" & 0.46"
- Sunlight Readable Display Models
- NEMA 4X, IP65 Front
- Programmable Display & Function Keys
- Universal 85-265 VAC, or 12/24 VDC Input Power Models
- 2 or 4 Relays + Isolated 4-20 mA Output Options
- External 4-Relay & Digital I/O Expansion Modules
- USB, RS-232, RS-485 Serial Communication Options
- Modbus® RTU Communication Protocol Standard
- Free PROPLUS Software for Operation, Monitoring, and Programming
Specifications
Accuracy
- ± 0.03 % of Calibrated Span ± 1 Count
- ± 0.1 % of Full Scale ± 0.004 mA - Isolated 4-20 mA Transmitter Output
Alarm
- High/Low
Approvals & Certifications
- CE
- UL
Communication
- Baud Rate: 300 to 19,200 bit/sec
- Data Length: 8-bits (1 Start Bit, 1 or 2 Stop Bits)
- Modbus RTU
- RS-232
- RS-422, RS-485
- Serial Communication Adapters
- USB
Current
- 1.5 mA Min. - Sink Current (Digital I/O Expansion Module)
- 10 mA - Max.
Deadband
- Relays: 0 to 100 % of Span, User Programmable
Delay Time
- < 2 milliseconds (Fixed) - Turn Around Delay
- 0 to 999.9 seconds - Relays
Display
- 0 to 999,999 (up to 999,999,999 with Total-Overflow Feature)
- 6-Digit Large Dual-Line Display (-99,999 to 999,999)
- Red LEDs with Leading Zero Blanking
- Upper: 0.60” High, Lower: 0.46” High
Electrical Connectors
- 12 to 22 AWG
- Digital I/O
- Removable Screw Terminal Block
- RJ45 for External Relays
Electrical Rating
- 1/14 hp at 125/250 Vac for Inductive Loads - Relay
- 125/250 Vac Resistive Load - Relay
- 3 A at 30 Vdc - Relay
Enclosure, Body Material
- High Impact Plastic
Environmental Protection
- IP65
- NEMA 4X
Frequency
- 0.001 Hz - Min. Input Frequency is Dependent on High Gate Setting
- 30,000 Hz (10,000 for Low Voltage Mag Pickup) - Max.
Function
- Password Protection
- Tare Function
Humidity
- 0 to 90 % Non-Condensing Relative Humidity
Input
- 0 to 1.25 Vdc - Digital Input Logic (Low)
- 0 to 12 V to Pulse or Square Wave
- 0 to 24 V at 30 kHz to Pulse or Square Wave
- 0-5 V - Pulse or Square Wave
- 3-5 Vdc - Digital Input Logic (High)
- 40 mV Peak-to-Peak Min. at 10 kHz - Coil (Sine Wave)
- Modbus PV (Slave)
- NPN/PNP Pulse
- Open Collector - Pulse Input
- Switch Contact - Pulse Input
- TTL
Input Impedance
- Open Collector/Switch Input: 4.7 kiloohms Pull-Up to 5 V
- Pulse Input: > 300 kiloohms at 1 kHz
Input Power
- 12/24 Vdc Powered Models Rated at 100 mA - Max.
- 85-265 Vac 50/60 Hz
Isolation
- 4 kV Input/Output-to-Power-Line
- 500 V Input to Output or Output to P+ Supply
K-Factor
- Programmed from 0.00001 to 999,999 Pulses/Unit
Linearization
- 2 to 32-Points - Multi-Point Linearization
Loop Resistance
- 10 to 700 ohms - for 24 Vdc Power Supply
- 100 to 1,200 ohms - for 35 Vdc (External) Power Supply
Mounting
- 1/8” DIN Panel Cutout Required: 3.622” x 1.772” (92 x 45 mm)
- Panel Mounting Bracket
Operating Temperature
- -40° to 65° C (-40° to 150° F)
Output
- 0-0.4 Vdc - Digital Output Logic (Low)
- 2 or 4 Relays
- 23 mA - Max.
- 3.1-3.3 Vdc - Digital Output Logic (High)
- 4-20 mA - Analog Output
Power Options
- 12/24 Vdc ± 10 %, 15 W, Max.
- 85-265 Vac, 50/60 Hz
- 90-265 Vdc, 20 W, Max.
Power Requirement
- 12/24 Vdc Powered Models Rated at 100 mA - Max.
- 24 Vdc ± 5 % at 200 mA - Max.
- 24 Vdc ± 5 % at 40 mA - Max.
- 35 Vdc, Max.
- 5/10 Vdc at 50 mA - Max.
Programming
- Cloning Using Copy Function
- Digital Inputs
- Four Front Panel Buttons
- Modbus Registers
- PC & MeterView Pro Software
Rating
- 2 or 4 SPDT (Form C) - Internal (Relays)
- 4 SPST (Form A) - External (Relays)
Relay Operation
- Automatic (Non-Latching)
- Latching (Requires Manual Acknowledge)
- Manual ON/OFF Control Mode
- Off (Disable Unused Relays & Enable Interlock Feature, Manual ON/OFF Control Mode)
- Pump Alternation Control (2 to 8 Relays)
- Sampling (Based on Time)
Sensitivity
- 40 mV Peak-to-Peak to 8 V Peak-to-Peak
Storage Temperature
- -40° to 85° C (-40° to 185° F)
Switch Type
- Transistor NPN or PNP
Thermal Drift
- 0.4 μA/°C, Max.
- 0.8 μA/°C, Max.
Torque
- 5 In/Lbs - Tightening Torque
Turn-Off Time
- 0.01 to 2.54 seconds - Byte-to-Byte Timeout
Update Time