Accuracy
- ± (1 % of Reading + 2-Digits) - AC Voltage (50/60 Hz)
- ± (1 % of Reading + 3-Digits) - AC Current (50/60 Hz)
- ± (1.2 % of Reading + 4-Digits) Beeps at below 30 ohms (Continuity Check) - Resistance
- ± (1.5 of Reading + 6-Digits) - AC Current (50/60 Hz)
- ± (1.5 % of Reading + 4-Digits) - AC Voltage (40 to 1,000 Hz)
- ± 2 % of Reading + 5-Digits - AC Current (40 to 1,000 Hz)
Approvals & Certifications
Approvals & Certifications
- Safety Standard: EN 61010-2-031
- Safety Standard: EN 61010-2-032
Battery Life
- Approximately 200 Hours (Continuous)
Conductor Position Effect
Consumption
- Consumed Current: Approximately 2 mA
Diameter
- Diameter of Measurable Conductor: 1.18” (30 mm) - Max.
Display
- LCD (Digital Display: 1,999 Counts)
External Magnetic Field Effect
Frequency
- 40 to 1,000 Hz, Accuracy: ± (1 % of Reading + 3-Digits)
Humidity
- 45 % Relative Humidity or Less - Operating Temperature & Humidity [Up to 50° C (122° F)]
- 75 % Relative Humidity or Less - Operating Temperature & Humidity [Up to 40° C (104° F)]
- 90 % Relative Humidity or Less - Operating Temperature & Humidity [Up to 30° C (86° F)]
Operating Temperature
- -10° to 50° C (14° to 122° F)
Power Requirement
- 6F22 (006P) 9 V x 1
- 6LR61 x 2
Response Time
- Approximately 1 second (Approximately 2 seconds on Resistance Range)
Supply Voltage
- AC Voltage: 200-600 V
- Circuit Voltage: 600 Vrms or Less
- Withstanding Voltage: 5.55 kVac for One Minute
Turn-Off Time
- Auto Power-Off: Approximately 10 minutes