Accuracy
- ± (1 % of Reading + 2-Digits) - AC Current (50/60 Hz)
- ± (1.5 % of Reading + 2-Digits) - AC Current (50/60 Hz)
- ± (2 % of Reading + 2-Digits) - AC Current (50/60 Hz)
- ± (3 % of Reading + 2-Digits) - AC Current (40 to 1,000 Hz)
- ± (3.5 % of Reading + 2-Digits) - AC Current (40 to 1,000 Hz)
- ± 10 % of Reading - AC Current (40 to 1,000 Hz)
- ± 2 % of Reading - AC Output (40 to 1,000 Hz, 50/60 Hz)
- ± 2.5 % of Reading - AC Current (40 to 1,000 Hz, 50/60 Hz)
- ± 3 % of Reading - AC & DC Output (40 to 1,000 Hz, 50/60 Hz)
- ± 3.5 % of Reading - DC Output (50/60 Hz)
- ± 4 % of Reading - DC Output (50/60 Hz)
- ± 5 % of Reading - AC Current (50/60 Hz), AC & DC Output (40 to 1,000 Hz)
- ± 5.5 % of Reading - DC Output (50/60 Hz)
- ± 7 % of Reading - DC Output (40 to 1,000 Hz)
- ± 7.5 % of Reading - DC Output (50/60 Hz)
Approvals & Certifications
Approvals & Certifications
- EN 61010-2-032 (Category III 300 V, Category II 600 V)
Battery Life
- Approximately 60 Hours (Continuous)
Conductor Position Effect
Consumption
- 5 mA Approximately - Consumed Current
Current
- 10 mA or Less in Proximity to A 10 mm-Diameter Conductor Carrying 100 A - Effect of Residual Current
- 200 mA to 1,000 A - AC Current
Diameter
- 2.6” (68 mm) - Diameter of Measurable Conductor
Display
- LCD (Digital Display: 1,999 Counts)
External Magnetic Field Effect
- 15 mA or Less in Proximity to A 10 mm-Diameter Conductor Carrying 100 A
Humidity
- 80 % Relative Humidity or Less (Non-Condensing)
Operating Temperature
- -10° to 50° C (14° to 122° F)
Output
- 200 mA to 1,000 A - AC & DC Output
Supply Voltage
- 3.7 kVac for One Minute - Withstanding Voltage
- 600 Vrms or Less - Circuit Voltage