CL360 Clamp-On Tester

Brand: Yokogawa Electric Corporation

With our 16 models of different clamp-on testers, Yokogawa provides the right tool for the job. 

Our CL Series consists of AC, AC/DC, and leakage current clamps with various ranges and dimensions. 

The multiple options include RMS, Mean, Temperature, frequency, and recorder output.
Features
  • Leakage current measurement with current range from 200 mA to 1,000 A
  • AC and DC output
  • 68 mm in diameter of measurable conductor
  • Approved for conformity to safety standards EN 61010-1, EN 61010-2-032 (CAT III 300 V)

Specifications

Accuracy

  • ± (1 % of Reading + 2-Digits) - AC Current (50/60 Hz)
  • ± (1.5 % of Reading + 2-Digits) - AC Current (50/60 Hz)
  • ± (2 % of Reading + 2-Digits) - AC Current (50/60 Hz)
  • ± (3 % of Reading + 2-Digits) - AC Current (40 to 1,000 Hz)
  • ± (3.5 % of Reading + 2-Digits) - AC Current (40 to 1,000 Hz)
  • ± 10 % of Reading - AC Current (40 to 1,000 Hz)
  • ± 2 % of Reading - AC Output (40 to 1,000 Hz, 50/60 Hz)
  • ± 2.5 % of Reading - AC Current (40 to 1,000 Hz, 50/60 Hz)
  • ± 3 % of Reading - AC & DC Output (40 to 1,000 Hz, 50/60 Hz)
  • ± 3.5 % of Reading - DC Output (50/60 Hz)
  • ± 4 % of Reading - DC Output (50/60 Hz)
  • ± 5 % of Reading - AC Current (50/60 Hz), AC & DC Output (40 to 1,000 Hz)
  • ± 5.5 % of Reading - DC Output (50/60 Hz)
  • ± 7 % of Reading - DC Output (40 to 1,000 Hz)
  • ± 7.5 % of Reading - DC Output (50/60 Hz)

Approvals & Certifications

  • CE

Approvals & Certifications

  • EN 61010-2-032 (Category III 300 V, Category II 600 V)

Battery Life

  • Approximately 60 Hours (Continuous)

Conductor Position Effect

  • 2 % or Less

Consumption

  • 5 mA Approximately - Consumed Current

Current

  • 10 mA or Less in Proximity to A 10 mm-Diameter Conductor Carrying 100 A - Effect of Residual Current
  • 200 mA to 1,000 A - AC Current

Diameter

  • 2.6” (68 mm) - Diameter of Measurable Conductor

Display

  • LCD (Digital Display: 1,999 Counts)

External Magnetic Field Effect

  • 15 mA or Less in Proximity to A 10 mm-Diameter Conductor Carrying 100 A

Frequency

  • 40 to 1,000 Hz

Humidity

  • 80 % Relative Humidity or Less (Non-Condensing)

Operating Temperature

  • -10° to 50° C (14° to 122° F)

Output

  • 200 mA to 1,000 A - AC & DC Output

Resolution

  • 0.1 mA

Response Time

  • 1 second

Supply Voltage

  • 3.7 kVac for One Minute - Withstanding Voltage
  • 600 Vrms or Less - Circuit Voltage