Approvals & Certifications
- EMC Electromagnetic Emission EN 61000-6-4, Immunity EN 61000-6-2
- ISO 9001 (DQS)
- QPS (C, US)
Approvals & Certifications
Consumption
- Current Consumption: 100 mA Typical, Dependent on Stroke Length
Electrical Protection
- Overvoltage Protection: up to 36 Vdc
- Polarity Protection: up to -30 Vdc
Enclosure, Body Material
- Sensor Electronics: AISI 303 Stainless Steel 1.4305
- Sensor Electronics: AISI 316L Stainless Steel, 1.4404
Flange Material
- AISI 303 Stainless Steel 1.4305
- AISI 316L Stainless Steel, 1.4404
Length
- Stroke Length: 1 to 118" (50 to 3,000 mm)
Linearity
- ≤ ± 0.02 % of Full Scale (Min. ± 60 µm)
Load
- 0 to 500 ohms for Current Output
- Minimum Load Controller: > 5 kΩ for Voltage Output
Materials of Construction
- Sensor Rod: 304L Stainless Steel 1.4306
- Sensor Rod: AISI 316L Stainless Steel, 1.4404
Metric Connection
- Threaded Flange: M18 x 1.5-6 G
Operating Pressure
- psi: 0 to 5,076 (kPa: 0 to 35,000, bar: 0 to 350)
Operating Temperature
- -40° to 85° C (-40° to 185° F)
Output
- 0-10 Vdc
- 0-20 mA
- 10-0 Vdc
- 20-0 mA
- 20-4 mA
- 4-20 mA
Principle of Operation
- Magnetostrictive Principle
Repeatability
- ≤ ± 0.005 % of Full Scale (Min. ± 20 µm) Typical
Resolution
- 16-bit (Min. 1 μm Depending on Stroke Length)
Shock
- 100 G (Single Shock), IEC 60068-2-27
Vibration
- 15 G (10 to 2000 Hz), IEC 60068-2-6 (Resonance Frequencies Excluded)
Voltage
- Dielectric Strength: 700 Vdc (DC Ground to Machine Ground)