EST120 2 in 1 Grain Temperature & Level Monitoring Transmitter

Part Number: EST120 Brand: FineTek
Price
$2,115.00 CAD
Stock
25+ In Stock

For silo management, users must install temperature sensing wire and grain level sensor separately in the past to get the information of temperature and grain level.

EST120 two-in-one silo temperature and grain level meter can synchronously measure grain temperature and level in the silo, to track and record grain condition, so as to provide you the optimal grain storage quality monitoring. 

EST120 adopts the RS485 communication interface, to transmit information to the central control room or human-machine interface. 

Users can monitor dual information of grain temperature and level in the silo from the far end, to conduct the most convenient and efficient grain storage management.
Features
  • Unique in the industry, EST120 transmitter integrated with simultaneous monitoring of grain level and temperature.
  • Steel cable design can effectively resist the impact of grain and prolong service life of the product.
  • Provide real-time multipoint temperature measurement to help managers cope with food more swiftly.
  • Detect whether there is fungus produced or there are activities of insects, to maintain food quality and facilitate long-term storage.
  • Prevent qualitative change of grain in the silo and fire disaster due to smolder.
  • Temperature measurement can be customized according to customer’s requirements.
  • Any two points of EST120 are in simple calibration mode of grain level.
  • The product uses open main current communication interface RS485. The system user can install the device on any system having the communication interface.

Specifications

Brand

Accuracy

  • ± 0.5° C (± 0.9° F)

Approvals & Certifications

  • CE

Cable Material

  • Coated with PVC, Inner Ring is Copper Wire

Communication

  • Baud Rate: 9,600, 14,400, 19,200, 38,400, 57,600, or 115,200 bit/sec
  • RS-485

Diameter

  • Outgoing Cable Diameter: Ø 5.5 to 11.2 mm

Environmental Protection

  • IP67

Flange Size - 1-1/2” (DN 40)

  • 1-1/2” (DN 40) - 150#
  • 1-1/2” (DN 40) - 300#
  • 1-1/2” (DN 40) - JIS 10K
  • 1-1/2” (DN 40) - JIS 5K

Flange Size - 2-1/2” (DN 65)

  • 2-1/2” (DN 65) - 150#
  • 2-1/2” (DN 65) - 300#
  • 2-1/2” (DN 65) - JIS 10K
  • 2-1/2” (DN 65) - JIS 5K

Flange Size - 2” (DN 50)

  • 2” (DN 50) - 150#
  • 2” (DN 50) - 300#
  • 2” (DN 50) - JIS 10K
  • 2” (DN 50) - JIS 5K

Flange Size - 3” (DN 80)

  • 3” (DN 80) - 150#
  • 3” (DN 80) - 300#
  • 3” (DN 80) - JIS 10K
  • 3” (DN 80) - JIS 5K

Flange Size - 4” (DN 100)

  • 4” (DN 100) - 150#
  • 4” (DN 100) - 300#
  • 4” (DN 100) - JIS 10K
  • 4” (DN 100) - JIS 5K

Flange Size - 5” (DN 125)

  • 5” (DN 125) - 150#
  • 5” (DN 125) - 300#
  • 5” (DN 125) - JIS 10K
  • 5” (DN 125) - JIS 5K

Flange Size - 6” (DN 150)

  • 6” (DN 150) - 150#
  • 6” (DN 150) - 300#
  • 6” (DN 150) - JIS 10K
  • 6” (DN 150) - JIS 5K

Input Power

  • 9-30 Vdc

Length

  • 100 feet (30 metres) - Max.

Load

  • Tensile Load (PE): 4,000 kgf
  • Tensile Load (PVC): 3,000 kgf

Materials of Construction

  • Junction Box: Aluminum Alloy (ADC-12)

Media

  • Solids

Non-Linearity

  • Grain Level: ± 1 % of Full Scale

NPT Connection

  • 1-1/4” NPT Male

PT/PF/PS (JIS) Connection

  • 1-1/4” PF Male

Resolution

  • 0.1° C (0.18° F)

Sample Rate

  • Grain Level Measurement: ≤ 1 second
  • Temperature Measurement: ≤ 1 second/Node

Temperature Range

  • -10° to 85° C (14° to 185° F)