EJA530E In-Line Gauge Pressure Transmitter
Brand: Yokogawa Electric CorporationThe high performance absolute and gauge pressure transmitter EJA510E and EJA530E feature single crystal silicon resonant sensor and are suitable to measure liquid, gas, or steam pressure.
EJA510E and EJA530E output a 4 to 20 mA DC signal corresponding to the measured pressure. It also features quick response, remote setup and monitoring via BRAIN or HART communications and self-diagnostics. FOUNDATION Fieldbus, PROFIBUS PA and 1 to 5 Vdc with HART (Low Power) protocol types are also available.
All EJA-E series models in their standard configuration, with the exception of the Fieldbus, PROFIBUS and Low Power types, are certified as complying with SIL 2 for safety requirement.
Features- Accuracy: ±0.055% of Span
- Response Time: 90 msec
- Stability: ±0.1% of URL per 10 years
Specifications
BSP Connection
- G 1/2” Male
O-Ring Material
- Buna-N - Cover O-Ring
- Fluororubber - Cover O-Rings
Damping Adjustment
- 0 to 100 seconds
Output Signal
- 4-20 mA DC (2-Wire) Output with Digital Communications
- 1-5 Vdc (3 or 4-Wire) Output with HART
Output
- 0.9-5.4 Vdc
- 3.6-21.6 mA
- 3.8-20.5 mA
Rotation
- 90°
Mounting
- 2” (50.8 mm) Pipe Mounting
Enclosure, Body Material
- ASTM CF-8M Stainless Steel
- Low Copper Cast Aluminum Alloy
Wetted Materials
- 316L Stainless Steel
- Hastelloy C-276
Operating Temperature
- -20° to 80° C (-4° to 176° F)
Zero Offset
- External Zero is Continuously Adjustable with 0.01 % Incremental Resolution of Span
Dead Time
- 45 milliseconds (Nominal)
Approvals & Certifications
- Leak Test
- Material Certificate
- Pressure Test
- SIL 2 Capability for Single Transmitter Use, SIL 3 Capability for Dual Transmitter Use, IEC 61508: 2000
Diaphragm Material
- Hastelloy C-276
Ambient Temperature Range
- -30° to 80° C (-22° to 176° F) with LCD Display
- -40° to 85° C (-40° to 185° F)
Response Time
- 90 milliseconds
Load
- 0 to 1,290 ohms - for Operation - for 4-20 mA HART/BRAIN
- 0.22 µF or Less - Load Capacitance
- 250 to 600 ohms for Digital Communication - for 4-20 mA HART/BRAIN
- 3.3 MH or Less - Load Inductance
Distance
- 0 to 2 Kilometers (1.25 Miles) when Using CEV - Communication Distance
Humidity
- 0 to 100 % Relative Humidity - Ambient
Stability
- ± 0.1 % of URL for 10-Years
Power Supply Effect
- ± 0.005 % Per Volt (21.6-32 Vdc, 350 ohms)
Accuracy
- ± (0.004 URL/Span) % of Span for High Accuracy (Includes the Effects of Terminal-based Linearity, Hysteresis & Repeatability) - for Capsule A
- ± (0.005 + 0.0035 URL/Span) % of Span for High Accuracy (Includes the Effects of Terminal-based Linearity, Hysteresis & Repeatability) - for Capsule B & D
- ± (0.0055 URL/Span) % of Span (Includes the Effects of Terminal-based Linearity, Hysteresis & Repeatability) - for Capsule A, B & C
- ± (0.0064 x 50 MPa/Span) % of Span for High Accuracy (Includes the Effects of Terminal-based Linearity, Hysteresis & Repeatability) - for Capsule D
- ± (0.0088 x 50 MPa/Span) % of Span (Includes the Effects of Terminal-based Linearity, Hysteresis & Repeatability) - for Capsule D
- ± 0.04 % of Span for High Accuracy (Includes the Effects of Terminal-based Linearity, Hysteresis & Repeatability)
- ± 0.055 % of Span (Includes the Effects of Terminal-based Linearity, Hysteresis & Repeatability)
Alarm
- Down-Scale: -5 %, 0.8 Vdc or Less - for 1-5 V HART
- Down-Scale: -5 %, 3.2 mA DC or Less - for 4-20 mA HART/BRAIN
- Up-scale: 110 %, 21.6 mA DC or more (Standard) - for 4-20 mA HART/BRAIN
- Up-scale: 110 %, 5.4 Vdc or more (Standard) - for 1-5 V HART
Plug Material
- 316 Stainless Steel - Blind Plug
Fluid
- Gas
- Liquid
Process Connection Material
- 316L Stainless Steel
- Hastelloy C-276
Output Load
- 1 Megaohm or Greater - for 1-5 V HART
Approvals & Certifications
- ATEX Flameproof & Intrinsically Safe
- CE
- CSA Explosion-proof & Intrinsically Safe
- EMC EN 61326-1 Class A, EN 61326-2-3, EN 61326-2-5 (For Fieldbus)
- FM Explosion-proof & Intrinsically Safe Approval
- IEC Ex Flameproof & Intrinsically Safe Approval
- NAMUR NE43
- PED 2014/68/EU
Display
- 5-Digit Numerical Display
- 6-Digit Unit Display
- Bar Graph
- LCD Display
- User-Configurable 10-Segment Signal Characterizer - for 4-20 mA Output
Supply Voltage
- 10.5-30 Vdc - for Intrinsically Safe, Typical N, Non-Incendive
- 10.5-32 Vdc - for Lightning Protector
- 10.5-42 Vdc - for General Use & Flameproof Typical
- 16.6 Vdc Min. - for Digital Communications
- 24 Vdc Supply, 0 to 550 ohms Load
- 9-32 Vdc - for Fieldbus Communication
Communication
- BRAIN
- FOUNDATION Fieldbus
- HART FSK Protocol
- PROFIBUS PA
Mounting Position Effect
- Tilting up to 90° will cause Zero Shift up to 0.21 kPa
Enclosure Finish
- Anti-Corrosion Coating
- Deep Sea Moss Green Paint (Munsell 0.6 GY3.1/2.0 or its Equivalent)
- Polyurethane Paint
Diagnostics
- Alarm
- Configuration Error
- CPU Failure
- Hardware Failure
- Process Alarm for Differential Pressure
Fill Material
- Fluorinated Oil
- Silicone
Cable Material
- Polyethylene Insulated PVC Sheathed
Process Temperature
- -40° to 120° C (-40° to 248° F)
NPT Connection
- 1/2” NPT Female
- 1/2” NPT Male
Environmental Protection
- Explosion-proof
- Flameproof
- Intrinsically Safe
- IP66
- IP67
- NEMA 4X
Metric Connection
- M20 x 1.5 Male DIN 16288
Consumption
- 0.96-3 mA - Power
- 27 mW - Power
NACE & NIST
- NACE MR-0103
Vibration Effect
- < ± 0.1 % of URL - IEC 60770-1 Field with General Application or Pipeline with Low Vibration Level (10-60 Hz 0.15 mm Displacement 60-500 Hz, 2 G)
- < 0.1 % of URL - IEC 60770-1 Field or Pipeline with High Vibration Level (10-60 Hz, 0.21 mm Displacement / 60-2,000 Hz, 3 G)
Pressure Range
- bar: -1 to 500
- kPa: -100 to 50,000
- psi: -14.5 to 7,200
Adjustment Type
- Push Button
- Screw - External Zero Adjustment
Temperature Effect
- ± (0.15 % of Span + 0.15 % of 50 MPa) Per 28° C (50° F) - for D Capsule Ambient Temperature Effects
- ± (0.15 % of Span + 0.15 % of URL) Per 28° C (50° F) - for A, B & C Capsule Ambient Temperature Effects
Screw Material
- 316 Stainless Steel - Zero-Adjustment Screw & Set Screws
Update Time
- 45 milliseconds
Supply Pressure - Maximum
- psi: 1,450 (kPa: 10,000, bar: 100) - Capsule C
- psi: 29 (kPa: 200, bar: 2) - Capsule A
- psi: 290 (kPa: 2,000, bar: 20) - Capsule B
- psi: 7,200 (kPa: 50,000, bar: 500) - Capsule D
Input Impedance
- 10 kiloohms or more at 2.4 kHz - for Communicating Device
Electrical Connectors
- 1/2” NPT Female
- G 1/2” Female
- M20 Female
Materials of Construction
- 316 Stainless Steel - Name Plate & Tag, Mounting Bracket
- Polypropylene - Pipe
Current
- 6,000 A, Max.
Overpressure & Static Pressure Limits
- psi: 2,900 (kPa: 20,000, bar: 200) - Capsule C, Max.
- psi: 580 (kPa: 4,000, bar: 40) - Capsule A & B, Max.
- psi: 8,700 (kPa: 59,980, bar: 599.8) - Capsule D, Max.
Pressure Type
- Gauge
Burst Pressure
- psi: 19,140 (kPa: 132,000, bar: 1,320) - Capsule D
- psi: 4,351 (kPa: 30,000, bar: 300) - Capsule A, B & C
Power Supply
- 9-28 Vdc for General Use & Flameproof Typical - for 1-5 V HART
Documentation
Data Sheets
- EJA-E Series HART 5/HART 7 Communication pdf 2.7 MB
- General Specifications - EJA-E Series Additional Approvals pdf 632 KB
- General Specifications - EJA-E Series FOUNDATION Fieldbus Protocol pdf 990 KB
- General Specifications - EJA-E Series PROFIBUS PA Protocol pdf 910 KB
- General Specifications - EJA530E pdf 1.4 MB
Brochure
Manual
- Communication Manual - EJA-E Series FOUNDATION Fieldbus Protocol pdf 3.7 MB
- Communication Manual - EJA-E Series HART Protocol pdf 12.2 MB
- Communication Manual - EJA-E Series PROFIBUS PA Protocol pdf 6.2 MB
- DPharp BRAIN Communication Type pdf 2.7 MB
- Hardware Manual- EJA530E Gauge Pressure Transmitter pdf 4.8 MB
- Installation Manual - EJA-E Series pdf 7.2 MB
- Manual Change 22-24E: EJX-A and EJA-E Series Differential Pressure and Pressure Transmitters pdf 186 KB
- Manual Change 22-25E: EJX/EJA-E series NEPSI Certification[Option code: /NF2, /NF21, /NS21, /NS24 and /NS25] pdf 312 KB
- User's Manual - EJA-E Series NEPSI Certification pdf 622 KB