V100/V110 Verabar Pitot Tube Flow Sensor

Brand: Yokogawa Electric Corporation

Developed from aerospace technology, the Verabar® averaging pitot flow sensor provides unsurpassed accuracy and reliability. 

With its solid, one-piece construction and bullet shape, the Verabar makes flow measurement leak proof and precise. 

The unique sensor shape reduces drag and flow induced vibration. 

The location of the low-pressure ports eliminates the potential for clogging and improves signal stability.
Features
  • Most Cost Effective Model
  • Installed in Less Than One Hour
  • Low and Medium Pressures

Specifications

Applications

  • Air (Compressed, Combustion)
  • Low Pressure Steam
  • Natural Gas
  • Non-Hazardous Fluids
  • Pipes (Steel, PVC, FRP, Copper)
  • Stack/Flue Gas
  • Water (Raw, Cooling, Feedwater)

Flange Size - 1” (DN 25)

  • 1” (DN 25) - 300# ANSI

Flange Size - 3/4” (DN 20)

  • 3/4” (DN 20) - 600# ANSI

Head Material

  • Stainless Steel - Instrument Head

Instrument Connection

  • 1/2” NPT

Materials of Construction

  • Carbon Steel - Plug, Weld Coupling
  • Stainless Steel - Tube Fitting, Weld Coupling, Plug

Media

  • Gas
  • Liquids
  • Steam

Mounting

  • Direct Mounting
  • Manifold
  • Remote Mounting
  • Tube Mounting

Mounting Position

  • Horizontal
  • Vertical

NPT Connection

  • 1” NPT - Weld Coupling Size
  • 3/4” NPT - Weld Coupling Size

Pipe Size

  • 2” to 6” (50 to 150 mm)
  • 6” to 48” (150 to 1,200 mm)

Pressure Range

  • psig: 0 to 1,440 (kPa: 0 to 9,930, bar: 0 to 99.3)

Pressure Type

  • Differential
  • Gauge

Process Fitting Details

  • Compression Fitting

Sensor, Probe Diameter

  • 7/16” (11 mm)
  • 7/8” (22 mm)

Sensor, Probe Material

  • 316 Stainless Steel

Sensor, Probe Type

  • RTD

Temperature Range

  • 38° to 426° C (100° to 800° F)

  • Air (Compressed, Combustion)
  • Low Pressure Steam
  • Natural Gas
  • Non-Hazardous Fluids
  • Pipes (Steel, PVC, FRP, Copper)
  • Stack/Flue Gas
  • Water (Raw, Cooling, Feedwater)