Approvals & Certifications
- CE
- EMC Test: Electromagnetic Emission According to EN 61000-6-3, Electromagnetic Immunity According to EN 61000-6-2
- IEC 60068-2-27, 60068-2-6
- UL 61010-1
Approvals & Certifications
- ISO 9001 (DQS)
- QPS (C, US)
Communication
- Baud Rate: 125, 250, 500, 800, 1,000 Kbps
- CAN System ISO -11898, Data Protocol (CANopen): CIA Standard DS 301 V3.0 / Encoder Profile DS 406 V3.1)
Consumption
- Current Consumption: 40-60 mA (Depending on Stroke Length)
Electrical Connectors
- M12 (5-Pin) Male Connector
Electrical Protection
- Overvoltage Protection: up to 36 Vdc
- Polarity Protection: up to -30 Vdc
Enclosure, Body Material
- Sensor Electronics: AISI 303 Stainless Steel 1.4305
- Sensor Electronics: AISI 316L Stainless Steel, 1.4404
Environmental Protection
- Ingress Protection: IP67
- Ingress Protection: IP69K (If Mating Cable Connector is Correctly Fitted)
Humidity
- 90 % Relative Humidity, Non-Condensing
Length
- Stroke Length: 2 to 100” (50 to 2,540 mm)
Linearity
- ≤ ± 0.02 % of Full Scale (Min. ± 60 µm)
Materials of Construction
- Sensor Rod 10 mm (0.39”) Rod-Ø : AISI 304L Stainless Steel 1.4306
- Sensor Rod 7 mm (0.28”) Rod-Ø : AISI 304 Stainless Steel 1.4301
- Sensor Rod: AISI 316L Stainless Steel, 1.4404
Operating Pressure
- 0.28” (7 mm) Rod-Ø psi: 4,351 to 6,527 (kPa: 30,000 to 45,000, bar: 300 to 450) Peak
- 0.39” (10 mm) Rod-Ø psi: 5,076 to 7,687 (kPa: 35,000 to 53,000, bar: 350 to 530) Peak
Operating Temperature
- -40° to 75° C (-40° to 167° F)
Principle of Operation
- Magnetostrictive Principle
Repeatability
- ≤ ± 0.005 % of Full Scale (Min. ± 20 µm)
Shock
- 100 G (Single Shock) IEC 60068-2-27
Vibration
- 15 G (10 to 2,000 Hz), IEC 60068-2-6 (Resonance Frequencies Excluded)
Voltage
- Dielectric Strength: 500 Vdc (DC Ground to Machine Ground)