YTA50 Head Mount Temperature Transmitter

Brand: Yokogawa Electric Corporation

The YTA50 is a head mount temperature transmitter with a single input.

The single input accepts thermocouples, RTD, Ohms or a DC millivolt source. All inputs are linearized and converted in to an industrial standard 4 to 20 mA DC output for transmission to your system.

YTA50 is the choice for your monitoring applications.
Features
  • 4 to 20 mA DC analog output
  • 16 Input Types
  • Head Mount or DIN Rail Mount

Specifications

Accuracy

  • ± 0.1 % of Span or ± 0.01 mV whichever is greater - DC Voltage
  • ± 0.1 % of Span or ± 0.1 ohm whichever is greater - Resistance
  • ± 0.1 % of Span or ± 0.2° C (± 0.36° F) whichever is greater - Pt100 & Ni100
  • ± 0.1 % of Span or ± 1° C (± 1.8° F) whichever is greater - Thermocouples E, J, K, N, T, L, U
  • ± 0.1 % of Span or ± 2° C (± 3.6° F) whichever is greater - Thermocouples B, R, S, W3, W5
  • ± 1° C (± 1.8° F) - Cold Junction Compensation Accuracy (Thermocouples)

Ambient Temperature Range

  • -40° to 85° C (-40° to 185° F)

Approvals & Certifications

  • ATEX: Intrinsically Safe Approval
  • EMC: EN 61326-1 Class A, EN 61326-2-3
  • FM: Intrinsically Safe/Non-Incendive

Electrical Connectors

  • M3 Screws - Terminals

Enclosure, Body Material

  • Polycarbonate

Environmental Protection

  • NEMA 4

Humidity

  • 5 to 90 % Relative Humidity at 40° C (104° F) - Ambient Humidity Limits

Input

  • -10 to 800 mV

Isolation

  • 1,500 Vac - Input/Output Isolation

Load

  • 739 ohms at 24 Vdc - Typical

Mounting

  • DIN Form B Connection Head

Output

  • 4-20 mA DC - 2-Wire

Power Supply Effect

  • ± 0.005 % of Full Scale Per Volt

Resistance

  • 0 to 5,000 ohms - Input Range
  • 10 megaohms - Input Signal Source Resistance (For Thermocouple Input)
  • 3 kiloohms at Power-Off - Input Signal Source Resistance (For Thermocouple Input)
  • 30 ohms - Min. Span
  • 5 ohms - Input Lead Wire Resistance (For RTDs Input)

Response Time

  • 1 to 60 seconds Programmable

RTD Type

  • Ni100 as Per DIN 43760
  • Pt100 as Per IEC 60751

Sensor Protection

  • Burn-Out - High or Low

Sensor, Probe Connection

  • 2-Wire RTD or ohm
  • 3-Wire RTD or ohm
  • 4-Wire RTD or ohm
  • T/C or DC mV

Sensor, Probe Type

  • B Thermocouple as Per IEC 60584
  • E Thermocouple as Per IEC 60584
  • J Thermocouple as Per IEC 60584
  • K Thermocouple as Per IEC 60584
  • L Thermocouple as Per DIN 43710
  • N Thermocouple as Per IEC 60584
  • RTD
  • R Thermocouple as Per IEC 60584
  • S Thermocouple as Per IEC 60584
  • T Thermocouple as Per IEC 60584
  • U Thermocouple as Per DIN 43710
  • W3 Thermocouple as Per ASTM E988-90
  • W5 Thermocouple as Per ASTM E988-90

Span - Minimum

  • 10° C (18° F) - RTD Typicals
  • 200° C (360° F) - Thermocouple
  • 5 mV - Dc Voltage

Supply Voltage

  • 7-30 Vdc - for Intrinsically Safe Typical
  • 7-35 Vdc

Temperature Effect

  • ± 0.1 % of Span or ± 0.1 ohm Per 10° C (18° F) whichever is greater - Resistance
  • ± 0.1 % of Span or ± 0.1° C (± 0.18° F) Per 10° C (18° F) whichever is greater - RTD Typical
  • ± 0.1 % of Span or ± 0.5° C (± 0.9° F) Per 10° C (18° F) whichever is greater - Thermocouples E, J, K, N, T, L, U
  • ± 0.1 % of Span or ± 10 μV Per 10° C (18° F) whichever is greater - DC Voltage
  • ± 0.1 % of Span or ± 2° C (± 3.6° F) Per 10° C (18° F) whichever is greater - Thermocouples B, R, S, W3, W5

Temperature Range

  • -200° to 2,300° C (-328° to 4,172° F) - Thermocouples
  • -200° to 850° C (-328° to 1,562° F) - RTD

Zero Offset

  • ± 50 % of The, Max.
show more