73204 Digital Multimeter

Brand: Yokogawa Electric Corporation

Specifications
  • Compact size, ideal for carrying
  • Large display for easy viewing
  • Safe design allows measurement in excess of 20 A (excluding 73204)
  • Special model for voltage measurement (73204)
  • Simple auto hold function
  • Capacitors can be checked (73202/73203)

Specifications

Accuracy

  • ± (0.5 % of Reading + 1-Digit) - DC Voltage
  • ± (0.75 % of Reading + 1-Digit) - Resistance
  • ± (0.75 % of Reading + 2-Digits) - Resistance
  • ± (0.75 % of Reading + 5-Digits) - AC Voltage
  • ± (1 % of Reading + 1-Digit) Testing Current 1 mA or Less - Diode Test
  • ± (2 % of Reading + 1-Digit) - Resistance
  • ± (5 % of Reading + 2-Digits) - Resistance

Battery Life

  • Approximately 600 Hours (For Continuous DC Voltage Measurement with Alkaline Cells)

Current

  • < 0.5 mA - Max.
  • < 0.7 µA - Max.
  • < 1 mA - Max.
  • < 7 µA - Max.
  • < 70 µA - Max.

Display

  • Digital Display: 4,300 Count Digital Reading

Function

  • Auto Hold
  • Overvoltage & Current Warning

Humidity

  • 70 % Relative Humidity, Non-Condensing or Less at 40° to 50° C (104° to 122° F) - Operating & Storage Humidity
  • 80 % Relative Humidity or Less at 0° to 40° C (32° to 104° F) - Operating Humidity

Input

  • 500 mA / 250 V (Fuse-Protected) - Input Protection (Capacitor Check)
  • 600 V, Max.
  • 600 Vrms, Max.

Measuring Range

  • 20 NF 200 μF - Capacitor Check
  • Digital Display: Approximately 2 times/second

Operating Temperature

  • 0° to 50° C (32° to 122° F)

Power Supply

  • 2 AAA Dry Cells (LR03 or R03)

Range

  • 0.4 to 600 V to AC & DC Voltage

Resistance

  • > 10 megaohms, 10 megaohms, 100 megaohms - Input Resistance (DC Voltage)
  • > 11 megaohms, 11 megaohms, 11 megaohms, 11 megaohms, < 50 PF - Input Resistance for AC Voltage
  • 10 megaohms - Input Resistance (DC Voltage)
  • 11 megaohms - Input Resistance (DC Voltage)
  • 400 ohms to 40 megaohms - Range
  • Buzzer Sounds at 50 ± 20 ohms or Less - Continuity Beeper (Continuity Check)

Response Time

  • 0.2 seconds or Less (Buzzer Response) - Continuity Check
  • 1 seconds or Less for 400 kiloohms Range - Resistance, Diode Test & Capacitor Check
  • 1.5 seconds or Less for 400 mV Range - DC Voltage
  • 15 seconds or Less for 40 megaohms Range - Resistance
  • 2 seconds or Less - DC Voltage
  • 5 seconds or Less for 4 megaohms Range - Resistance

Storage Temperature

  • -20° to 60° C (-4° to 140° F)

Supply Voltage

  • < 0.7 V - Open Circuit Voltage (Resistance)
  • < 1.0 V - Open Circuit Voltage (Resistance)
  • < 3.4 V - Open Circuit Voltage (Resistance)
  • 5.55 kVac for 1 Minute - Withstanding Voltage
show more