73204 Digital Multimeter
Brand: Yokogawa Electric Corporation
Specifications
- Compact size, ideal for carrying
- Large display for easy viewing
- Safe design allows measurement in excess of 20 A (excluding 73204)
- Special model for voltage measurement (73204)
- Simple auto hold function
- Capacitors can be checked (73202/73203)
Specifications
Accuracy
- ± (0.5 % of Reading + 1-Digit) - DC Voltage
- ± (0.75 % of Reading + 1-Digit) - Resistance
- ± (0.75 % of Reading + 2-Digits) - Resistance
- ± (0.75 % of Reading + 5-Digits) - AC Voltage
- ± (1 % of Reading + 1-Digit) Testing Current 1 mA or Less - Diode Test
- ± (2 % of Reading + 1-Digit) - Resistance
- ± (5 % of Reading + 2-Digits) - Resistance
Battery Life
- Approximately 600 Hours (For Continuous DC Voltage Measurement with Alkaline Cells)
Current
- < 0.5 mA - Max.
- < 0.7 µA - Max.
- < 1 mA - Max.
- < 7 µA - Max.
- < 70 µA - Max.
Display
- Digital Display: 4,300 Count Digital Reading
Function
- Auto Hold
- Overvoltage & Current Warning
Humidity
- 70 % Relative Humidity, Non-Condensing or Less at 40° to 50° C (104° to 122° F) - Operating & Storage Humidity
- 80 % Relative Humidity or Less at 0° to 40° C (32° to 104° F) - Operating Humidity
Input
- 500 mA / 250 V (Fuse-Protected) - Input Protection (Capacitor Check)
- 600 V, Max.
- 600 Vrms, Max.
Measuring Range
- 20 NF 200 μF - Capacitor Check
- Digital Display: Approximately 2 times/second
Operating Temperature
- 0° to 50° C (32° to 122° F)
Power Supply
- 2 AAA Dry Cells (LR03 or R03)
Range
- 0.4 to 600 V to AC & DC Voltage
Resistance
- > 10 megaohms, 10 megaohms, 100 megaohms - Input Resistance (DC Voltage)
- > 11 megaohms, 11 megaohms, 11 megaohms, 11 megaohms, < 50 PF - Input Resistance for AC Voltage
- 10 megaohms - Input Resistance (DC Voltage)
- 11 megaohms - Input Resistance (DC Voltage)
- 400 ohms to 40 megaohms - Range
- Buzzer Sounds at 50 ± 20 ohms or Less - Continuity Beeper (Continuity Check)
Response Time
- 0.2 seconds or Less (Buzzer Response) - Continuity Check
- 1 seconds or Less for 400 kiloohms Range - Resistance, Diode Test & Capacitor Check
- 1.5 seconds or Less for 400 mV Range - DC Voltage
- 15 seconds or Less for 40 megaohms Range - Resistance
- 2 seconds or Less - DC Voltage
- 5 seconds or Less for 4 megaohms Range - Resistance
Storage Temperature
- -20° to 60° C (-4° to 140° F)
Supply Voltage
- < 0.7 V - Open Circuit Voltage (Resistance)
- < 1.0 V - Open Circuit Voltage (Resistance)
- < 3.4 V - Open Circuit Voltage (Resistance)
- 5.55 kVac for 1 Minute - Withstanding Voltage