GHG-Control

Brand: Sick AG

Continuous, reliable ,and real-time measurement of the current CO2 and N2O load: The GHG-Control gas analyzer from SICK is an in-situ solutions that provides companies with an overview of the amount of greenhouse gases emitted at any time.

GHG-Control records the CO2/N2O gas concentration and their volume flow, and determines the total quantity very precisely.

GHG-Control does not involve the expensive process of recording the calculation basis, sampling and measurement of substance flows, and intermittent lab analyses, especially in the event of changing fuel qualities or fuel carbon content.

The greenhouse gas loads are released directly to the SCU control unit.

By dispensing with the expensive calculation method of the CO2 and N2O load, the safety supplements for the calculation methods are no longer required, and only the actual emitted emissions are reported and paid for.
Features
  • In-situ solution for measuring CO2 and N2O emissions
  • Direct measurement even with changing fuels and mixed fuels
  • Measurement without converting from the dry to damp status
  • Transfer of the greenhouse gas loads directly to the control unit
  • Simple data collection for companies that are required to report greenhouse gases
  • Precise calculation of greenhouse gas loads within the framework of an emission trading or pollution tax system

Specifications

Brand

Certifications & Approvals

  • CE

Environmental Protection

  • IP65 / NEMA 4X
  • IP54

Storage Temperature

  • FLOWSIC100: -40° to 70° C

Ambient Temperature

  • FLOWSIC100: -40° to 60° C
  • SLV4-2 Purge Air Unit: -40° to 55° C

Ambient Humidity

  • ≤ 96 % Relative Humidity, Non-Condensing

Gas Flow Rate

  • 38 to 63 m³/h at 30 hPa counter Pressure, depending on Low Pressure inside the filter

Measured Value

  • CO, CO₂, H₂O, N₂O

Measuring Range

  • Gas Velocity -40 to 40 m/s
  • N₂O: 0 to 2,500 ppm
  • CO₂ & H₂O: 0 to 100 Vol %
  • CO: 0 to 20,000 ppm

Response Time

  • FLOWSIC100 System: 1 to 300 s

Process Temperature

  • FLOWSIC100 M & FLOWSIC100 H: -40° to 260° C

Process Pressure

  • FLOWSIC100 M & FLOSIC100 H: -100 to 100 hPa

Power Consumption

  • FLOWSIC100 M & FLOWSIC100 H: ≤ 40 W

Documentation

show more