EJX440A High Gauge Pressure Transmitter
Brand: Yokogawa Electric CorporationThe high performance gauge pressure transmitter EJX440A features single crystal silicon resonant sensor and is suitable to measure liquid, gas, or steam pressure.
The EJX440A outputs a 4 to 20 mA DC signal corresponding to the measured pressure. It also features quick response, remote setup and monitoring via BRAIN or HART communications, and diagnostics.
The multi-sensing technology provides the advanced diagnostic function to detect such abnormalities as an impulse line blockage or heat trace breakage.
FOUNDATION Fieldbus and PROFIBUS PA protocol types are also available.
All EJX series models in their standard configuration, with the exception of the Fieldbus and PROFIBUS types, are certified by TÜV as complying with SIL 2 for safety requirement.
Features- Accuracy: ± 0.04% of Span
- Response Time: 90 msec
- Stability: ± 0.1% of URL per 15 years
Specifications
Accuracy
- ± (0.005 + 0.0035 URL/Span) % of Span - Capsule D
- ± (0.005 + 0.0055 URL/Span) % of Span - Capsule C
- ± 0.04 % of Span - Capsule C & D
Adjustment Type
- Push Button
- Screw - External Zero Adjustment
Alarm
- Down-Scale: -5 %, 3.2 mA DC or Less
- Up-Scale: 110 %, 21.6 mA DC or more
Ambient Temperature Range
- -30° to 80° C (-22° to 176° F) - with LCD Display
- -40° to 85° C (-40° to 185° F)
Approvals & Certifications
- Leak Test
- Material Certificate
- Pressure Test
- SIL 2 Capability for Single Transmitter Use, SIL 3 Capability for Dual Transmitter Use, IEC 61508: 2000
- TÜV (Technischer Uberwachungsverein)
Approvals & Certifications
- ATEX Flameproof & Intrinsically Safe
- CE
- CSA Explosion-proof & Intrinsically Safe
- EMC EN 61326-1 Class A (For Industrial Locations), EN 61326-2-3, EN 61326-(For Fieldbus)
- FM Explosion-proof & Intrinsically Safe
- IECEx Intrinsically Safe & Flameproof Approval
- NAMUR NE43
- PED 2014/68/EU-Sound Engineering Practice
Burst Pressure
- psi: 19,100 (MPa: 132, bar: 1,320)
Cable Material
- Polyethylene Insulated PVC Sheathed
Communication
- BRAIN
- FOUNDATION Fieldbus
- HART
- PROFIBUS PA
Damping Adjustment
- 0 to 100 seconds
Diagnostics
- Capsule Temperature
- Configuration Error
- CPU Failure
- Hardware Failure
- Over-Range Error
- Process Alarm for Pressure
Diaphragm Material
- Hastelloy C-276
Display
- 10-Segment - User Configurable, Signal Characterizer for 4-20 mA Output
- 5-Digit Numerical Display
- 6-Digit Unit Display
- Bar Graph
- LCD Display
Distance
- 0 to 2 Kilometers (1.25 Miles) - Communication Distance
Drain, Vent Valves & Plug
- 316 Stainless Steel
Electrical Connectors
- 1/2” NPT Female
- G 1/2” Female
- M20 Female
Electrical Protection
- Lightning Protection
Electrical Rating
- 120 mA DC, Max.
Enclosure Finish
- Anti-Corrosion Coating
- Polyurethane Paint, Mint Green Paint (Munsell 5.6BG 3.3/2.9 or its Equivalent)
Enclosure, Body Material
- ASTM CF-8M Stainless Steel
- Low Copper Cast Aluminum Alloy
Environmental Protection
- IP66
- IP67
- NEMA 4X
Fill Material
- Fluorinated Oil
- Silicone
Flange Material
- F316 Stainless Steel - Cover Flange
Fluid
- Gas
- Liquid
Gasket Material
- Glass Reinforced Teflon - for Capsule C
- Teflon-Coated 316L Stainless Steel - Capsule Gasket
Humidity
- 0 to 100 % Relative Humidity - Ambient Humidity
Indication
- Digital
Input Impedance
- 10 kiloohms or more at 2.4 kHz - Communicating Device
Length
- 1.33” (34 mm) Standard - Long Vent
- 4.6” (119 mm) - Long Vent
Load
- 0 to 1,290 ohms - for Operation
- 0.22 μF or Less - Load Capacitance
- 250 to 600 ohms - for Digital Communication
- 3.3 MH or Less - Load Inductance
Materials of Construction
- 316 Stainless Steel - Name Plate & Tag
Measuring Time
- 45 milliseconds Nominal - Dead Time
Mounting
- 2” Pipe Mounting Bracket
Mounting Position Effect
- Tilting up to 90° will cause Zero Shift up to 0.4 kPa
NACE & NIST
- NACE MR-0103
- NACE MR-0175, ISO 15156
NPT Connection
- 1/2” NPT Female
- 1/4” NPT Female
Nut & Bolt Material
- 316L Stainless Steel
- 660 Stainless Steel
- B7 Carbon Steel
O-Ring Material
- Buna-N - Cover O-Ring
- Fluorinated Rubber - Cover O-Rings
Operating Temperature
- -20° to 80° C (-4° to 176° F)
Output
- 3.6-21.6 mA
- 4-20 mA DC (2-Wire)
Output Format
- Transistor Output
Overpressure & Static Pressure Limits
- psi: 10,800 (kPa: 74,460, bar: 744.6) - Capsule D, Max.
- psi: 6,750 (kPa: 48,000, bar: 465.4) - Capsule C, Max.
Power Supply Effect
- ± 0.005 % Per Volt (From 21.6 to 32 Vdc, 350 ohms)
Pressure Range
- bar: -1 to 500
- kPa: -100 to 50,000
- psi: -14.5 to 7,200
Pressure Type
- Gauge
Process Connection Material
- 316 Stainless Steel (D-Caspule)
- ASTM CF-8M (C-Capsule)
Process Temperature
- -40° to 120° C (-40° to 248° F)
Response Time
- 90 milliseconds
Screw Material
- 316 Stainless Steel
Stability
- ± 0.1 % of URL Per 15-Years
Supply Pressure - Maximum
- psi: 4,500 (MPa: 32, bar: 320) - Capsule C
- psi: 7,200 (MPa: 50, bar: 500) - Caspule D
Supply Voltage
- 10.5-30 Vdc - for Intrinsically Safe, Typical N or Non-Incendive Typical
- 10.5-32 Vdc - for Lightning Protector
- 10.5-42 Vdc - for General Use & Flameproof Typical
- 16.6 Vdc - for Digital Communications, BRAIN & HART
- 24 Vdc up to A 550 ohms Load
Temperature Effect
- ± (0.04 % of Span + 0.009 % of URL) Per 28° C (50° F) - Capsule D Ambient Temperature Effect
- ± [0.04 % of Span + 0.0141 % of URL] Per 28° C (50° F) - Capsule C Ambient Temperature Effect
Update Time
- 45 milliseconds - Pressure
Vibration Effect
- < 0.1 % of URL
Wetted Materials
- 316L Stainless Steel
- F316L Stainless Steel
Zero Offset
- External Zero is Continuously Adjustable with 0.01 % Incremental Resolution of Span
Documentation
Data Sheets
Certificate
Manual
- Differential Pressure and Pressure Transmitter pdf 6.3 MB
- DPharp BRAIN Communication Type pdf 2.7 MB
- DPharp Fieldbus Communication Type pdf 3.7 MB
- DPharp HART 5/7 Communication Type pdf 12.2 MB
- DPharp PROFIBUS PA Communication Type pdf 6.2 MB
- EJX and EJA-E Series Differential Pressure and Pressure Transmitters Installation Manual pdf 7.2 MB
- EJX/EJA-E series NEPSI Certification[Option code: /NF2, /NF21, /NS21, /NS24 and /NS25] pdf 622 KB
- Manual Change 22-24E: EJX-A and EJA-E Series Differential Pressure and Pressure Transmitters pdf 186 KB
- Manual Change 22-25E: EJX/EJA-E series NEPSI Certification[Option code: /NF2, /NF21, /NS21, /NS24 and /NS25] pdf 312 KB