EJX440A High Gauge Pressure Transmitter

Brand: Yokogawa Electric Corporation

The high performance gauge pressure transmitter EJX440A features single crystal silicon resonant sensor and is suitable to measure liquid, gas, or steam pressure. 

The EJX440A outputs a 4 to 20 mA DC signal corresponding to the measured pressure. It also features quick response, remote setup and monitoring via BRAIN or HART communications, and diagnostics.

The multi-sensing technology provides the advanced diagnostic function to detect such abnormalities as an impulse line blockage or heat trace breakage. 

FOUNDATION Fieldbus and PROFIBUS PA protocol types are also available.

All EJX series models in their standard configuration, with the exception of the Fieldbus and PROFIBUS types, are certified by TÜV as complying with SIL 2 for safety requirement.
Features
  • Accuracy: ± 0.04% of Span
  • Response Time: 90 msec
  • Stability: ± 0.1% of URL per 15 years

Output Signal

Output Signal

Measurement Span

Measurement Span

Wetted Material

Wetted Material

Process Connection

Process Connection
  • view details
  • view details

Bolts & Nuts Material

Bolts & Nuts Material

Installation

Installation

Amplifier Housing

Amplifier Housing
  • view details
  • view details

Electrical Connection

Electrical Connection
  • view details
  • view details
  • view details

Integral Indicator

Integral Indicator

Mounting Bracket Kit

Mounting Bracket Kit

FM Approval

FM Approval

ATEX Approval

ATEX Approval

CSA Approval

CSA Approval
  • view details
  • view details

IECEx Approval

IECEx Approval
  • view details

Combination of Approvals

Combination of Approvals

Painting

Painting

Exterior Parts

Exterior Parts

O-Ring

O-Ring

Lightning Protection

Lightning Protection
  • view details

Status Output

Status Output

Oil-Prohibited Use

Oil-Prohibited Use
  • view details
  • view details

Fill Fluid

Fill Fluid
  • view details

Calibration Unit

Calibration Unit

Vent Size

Vent Size

Gasket Material

Gasket Material
  • view details

Plating

Plating
  • view details

Output Limits & Failure Operation

Output Limits & Failure Operation
  • view details
  • view details
  • view details

Body Configuration

Body Configuration
  • view details
  • view details
  • view details

Wired Tag Plate

Wired Tag Plate

Data Configuration

Data Configuration

Advanced Diagnostic Functionality

Advanced Diagnostic Functionality
  • view details

European Pressure Equipment Directive

European Pressure Equipment Directive
  • view details

Material Certificate

Material Certificate

Pressure Test / Leak Test Certificate

Pressure Test / Leak Test Certificate
  • view details
  • view details
View Details
Part Number / SKU

undefined

  • Output Signal

    4-20 mA DC with Digital Communication, BRAIN Protocol

  • Measurement Span

    0.25 to 32 MPa (36 to 4,500 psi)

  • Wetted Material

    F316 Stainless Steel

  • Process Connection

    Without Process Connector (1/4” NPT Female on the Cover Flanges)

  • Bolts & Nuts Material

    B7 Carbon Steel

  • Installation

    Horizontal Piping & Left Side High Pressure

  • Amplifier Housing

    Cast Aluminum Alloy

  • Electrical Connection

    1/2” Female NPT, Two Electrical Connections without Blind Plugs

  • Integral Indicator

    No Integral Indicator

  • Mounting Bracket Kit

    304 Stainless Steel 2-Inch Pipe Mounting, Flat Type (For Horizontal Piping)

  • FM Approval

    Without FM Approval

  • ATEX Approval

    Without ATEX Approval

  • CSA Approval

    Without CSA Approval

  • IECEx Approval

    Without IECEx Approval

  • Combination of Approvals

    Without Combination of Approvals

  • Painting

    Polyurethane, Mint-Green Paint (Munsell 5.6BG 3.3/2.9 or its Equivalent)

  • Exterior Parts

    Standard Materials

  • O-Ring

    Buna-N O-Ring

  • Lightning Protection

    Without Lightning Protection

  • Status Output

    Without Status Output

  • Oil-Prohibited Use

    No Oil-Prohibited Use

  • Fill Fluid

    Silicone Fill Fluid

  • Calibration Unit

    kPa Calibration (kPa Unit)

  • Vent Size

    34 mm (Standard)

  • Gasket Material

    Teflon-Coated 316L Stainless Steel

  • Plating

    No Plating on Diaphragms

  • Output Limits & Failure Operation

    Up-Scale: 110 %, 21.6 mA DC or More

  • Body Configuration

    No Body Configuration

  • Wired Tag Plate

    Without Wired Tag Plate

  • Data Configuration

    Without Data Configuration

  • Advanced Diagnostic Functionality

    No Advanced Diagnostic Functionality

  • European Pressure Equipment Directive

    Without European Pressure Equipment Directive

  • Material Certificate

    Without Material Certificate

  • Pressure Test / Leak Test Certificate

    Without Pressure Test / Leak Test Certificate

Specifications

Accuracy

  • ± (0.005 + 0.0035 URL/Span) % of Span - Capsule D
  • ± (0.005 + 0.0055 URL/Span) % of Span - Capsule C
  • ± 0.04 % of Span - Capsule C & D

Adjustment Type

  • Push Button
  • Screw - External Zero Adjustment

Alarm

  • Down-Scale: -5 %, 3.2 mA DC or Less
  • Up-Scale: 110 %, 21.6 mA DC or more

Ambient Temperature Range

  • -30° to 80° C (-22° to 176° F) - with LCD Display
  • -40° to 85° C (-40° to 185° F)

Approvals & Certifications

  • Leak Test
  • Material Certificate
  • Pressure Test
  • SIL 2 Capability for Single Transmitter Use, SIL 3 Capability for Dual Transmitter Use, IEC 61508: 2000
  • TÜV (Technischer Uberwachungsverein)

Approvals & Certifications

  • ATEX Flameproof & Intrinsically Safe
  • CE
  • CSA Explosion-proof & Intrinsically Safe
  • EMC EN 61326-1 Class A (For Industrial Locations), EN 61326-2-3, EN 61326-(For Fieldbus)
  • FM Explosion-proof & Intrinsically Safe
  • IECEx Intrinsically Safe & Flameproof Approval
  • NAMUR NE43
  • PED 2014/68/EU-Sound Engineering Practice

Burst Pressure

  • psi: 19,100 (MPa: 132, bar: 1,320)

Cable Material

  • Polyethylene Insulated PVC Sheathed

Communication

  • BRAIN
  • FOUNDATION Fieldbus
  • HART
  • PROFIBUS PA

Damping Adjustment

  • 0 to 100 seconds

Diagnostics

  • Capsule Temperature
  • Configuration Error
  • CPU Failure
  • Hardware Failure
  • Over-Range Error
  • Process Alarm for Pressure

Diaphragm Material

  • Hastelloy C-276

Display

  • 10-Segment - User Configurable, Signal Characterizer for 4-20 mA Output
  • 5-Digit Numerical Display
  • 6-Digit Unit Display
  • Bar Graph
  • LCD Display

Distance

  • 0 to 2 Kilometers (1.25 Miles) - Communication Distance

Drain, Vent Valves & Plug

  • 316 Stainless Steel

Electrical Connectors

  • 1/2" NPT Female
  • G 1/2" Female
  • M20 Female

Electrical Protection

  • Lightning Protection

Electrical Rating

  • 120 mA DC, Max.

Enclosure Finish

  • Anti-Corrosion Coating
  • Polyurethane Paint, Mint Green Paint (Munsell 5.6BG 3.3/2.9 or its Equivalent)

Enclosure, Body Material

  • ASTM CF-8M Stainless Steel
  • Low Copper Cast Aluminum Alloy

Environmental Protection

  • IP66
  • IP67
  • NEMA 4X

Fill Material

  • Fluorinated Oil
  • Silicone

Flange Material

  • F316 Stainless Steel - Cover Flange

Fluid

  • Gas
  • Liquid

Gasket Material

  • Glass Reinforced Teflon - for Capsule C
  • Teflon-Coated 316L Stainless Steel - Capsule Gasket

Humidity

  • 0 to 100 % RH - Ambient Humidity

Indication

  • Digital

Input Impedance

  • 10 kΩ or more at 2.4 kHz - Communicating Device

Length

  • 1.33" (34 mm) Standard - Long Vent
  • 4.6" (119 mm) - Long Vent

Load

  • 0 to 1,290 ohms - for Operation
  • 0.22 μF or Less - Load Capacitance
  • 250 to 600 ohms - for Digital Communication
  • 3.3 MH or Less - Load Inductance

Materials of Construction

  • 316 Stainless Steel - Name Plate & Tag

Measuring Time

  • 45 ms Nominal - Dead Time

Mounting

  • 2" Pipe Mounting Bracket

Mounting Position Effect

  • Tilting up to 90° will cause Zero Shift up to 0.4 kPa

NACE & NIST

  • NACE MR-0103
  • NACE MR-0175, ISO 15156

NPT Connection

  • 1/2" NPT Female
  • 1/4" NPT Female

Nut & Bolt Material

  • 316L Stainless Steel
  • 660 Stainless Steel
  • B7 Carbon Steel

O-Ring Material

  • Buna-N - Cover O-Ring
  • Fluorinated Rubber - Cover O-Rings

Operating Temperature

  • -20° to 80° C (-4° to 176° F)

Output

  • 3.6 - 21.6 mA
  • 4-20 mA DC (2-Wire)

Output Format

  • Transistor Output

Overpressure & Static Pressure Limits

  • psi: 10,800 (kPa: 74,460, bar: 744.6) - Capsule D, Max.
  • psi: 6,750 (kPa: 48,000, bar: 465.4) - Capsule C, Max.

Power Supply Effect

  • ± 0.005 % per Volt (From 21.6 - 32 Vdc, 350 ohms)

Pressure Range

  • bar: -1 to 500
  • kPa: -100 to 50,000
  • psi: -14.5 to 7,200

Pressure Type

  • Gauge

Process Connection Material

  • 316 Stainless Steel (D-Caspule)
  • ASTM CF-8M (C-Capsule)

Process Temperature

  • -40° to 120° C (-40° to 248° F)

Response Time

  • 90 ms

Screw Material

  • 316 Stainless Steel

Stability

  • ± 0.1 % of URL Per 15-Years

Supply Pressure - Maximum

  • psi: 4,500 (MPa: 32, bar: 320) - Capsule C
  • psi: 7,200 (MPa: 50, bar: 500) - Caspule D

Supply Voltage

  • 10.5-30 Vdc - for Intrinsically Safe, Typical N or Non-Incendive Typical
  • 10.5-32 Vdc - for Lightning Protector
  • 10.5-42 Vdc - for General Use & Flameproof Typical
  • 16.6 Vdc - for Digital Communications, BRAIN & HART
  • 24 Vdc up to A 550 ohms Load

Temperature Effect

  • ± (0.04 % of Span + 0.009 % of URL) Per 28° C (50° F) - Capsule D Ambient Temperature Effect
  • ± [0.04 % of Span + 0.0141 % of URL] Per 28° C (50° F) - Capsule C Ambient Temperature Effect

Update Time

  • 45 ms - Pressure

Vibration Effect

  • < 0.1 % of URL

Wetted Materials

  • 316L Stainless Steel
  • F316L Stainless Steel

Zero Offset

  • External Zero is Continuously Adjustable with 0.01 % Incremental Resolution of Span
show more