Rotamass 3 RCCT3 Integral Converter

Brand: Yokogawa Electric Corporation

ROTAMASS is a Coriolis mass flowmeter with highly refined digital signal processing electronics, so that accurate and stable mass flow measurement is achieved.

ROTAMASS employs a flame-proof type converter case suitable for use in the hazardous area together with it’s intrinsically safety type detector.

ROTAMASS's signal processing, housing protection and its detector's special decoupling system against external loads and vibrations, realize high performance in real applications.
Features
  • ROTAMASS is a flowmeter for nearly all fluids, including high viscosity liquids, slurries and multi-phase media with a certain gas content
  • Refined digital signal processing enables accurate and stable measurement
  • A special detector decoupling system makes the device highly independent from external loads or vibrations
  • Simple flow path means self-draining, simple cleaning and suitable for use in hygenic industries
  • High accuracy and high stability over a wide flow range
  • Accurate density measurement, up to ±0.0005 g/cm³
  • Concentration measurement for solutions, suspensions and emulsions (Example: water cut, net oil computing)
  • Volume flow with reference density
  • Temperature measurement
  • Two Analog outputs, two pulse outputs or status-out and one status-in as standard I/O
  • Available in Explosion proof versions (ATEX, FM, IECEx, EAC, INMETRO, NEPSI, KOSHA)
  • European MID approval according to OIML R-117-1 and American NTEP approval for Custody Transfer Measurement
  • Wide process temperature range -200° to 350° C
  • Microprocessor-based multifunction capability
  • EEPROM protects parameter settings and totalized values during power failure
  • High visibly LCD display
  • HART communication function is available
  • Optional Foundation™ Fieldbus communication is available
  • Optional MODBUS® communication is available
  • Optional intrinsically safe outputs are available
  • Various choice of tubes materials
  • EN, ASME or JIS flanges as standard
  • SIL 2, SIL 3 levels can be achieved if redundant meters are used

Specifications

Accuracy

  • ± 0.001 g/cm³ - Density Adjustment & Thermal Treatment
  • ± 0.0005 g/cm³ - Density Calibration with 3 Different Fluids Including Individual Temperature Compensation
  • ± 0.0015 to ± 0.02 g/cm³ (Standard)
  • ± 0.5 % of Flow Rate ± Zero Stability/Flow Rate *100 % - Mass Flow (Gas)

Ambient Temperature Range

  • 22.5° C ± 12.5° C (72.5° F ± 22.5° F) - Factory Calibration for Liquids & Gases

Approvals & Certifications

  • Compliance According to EN 10204: 2004-2.1
  • Dye Penetration Test According to DIN EN ISO 3452-1
  • Mass/Volume-Flow Calibration Using Water with Factory Calibration Certification
  • Mass/Volume-Flow Calibration with DAkkS Certificate EN 17025: 2005
  • Material Certificate According to EN 10204: 2004 -3.1
  • PMI
  • Pressure Test Report Measuring System
  • SIL 2, SIL 3 (FMEDA Report)

Approvals & Certifications

  • American NTEP Approval 12-080A2 for Custody Transfer Measurement
  • ATEX: KEMA 02-ATEX-2183 x & KEMA 01-ATEX-1075 X, Flameproof & Intrinsically Safe
  • CRN 0F12074.5 Approved Process Connections
  • EAC: Flameproof & Intrinsically Safe
  • EHEDG
  • EMC: EN 61326-1: 2006, Class A, EN 61326-2-3: 2006, EN 61000-3-2: 2006 & EN 61000-3-3: 2008
  • European MID Approval According to OIML R-117-1 (Fluids other than Water)
  • FM: Intrinsically Safe & Housing Explosion-proof
  • GOST
  • IEC Ex: KEM 06.0031X, Intrinsically Safe, Flameproof
  • INMETRO: Flameproof & Intrinsically Safe
  • KOSHA
  • NAMUR: EN 60947-5-6
  • NEPSI: Flameproof & Intrinsically Safe
  • PED 97/23/EC

BSP Connection

  • G 1/2” Female
  • G 1/4” Female
  • G 3/4” Female

Cable Entry

  • Cable Gland, 2-Pieces ANSI 1/2” NPT / G 1/2” Adapter

Cable Length

  • ≤ 6,562 feet (2,000 metres)

Communication

  • Baud Rate: 1,200, 2,400, 4,800, 9,600, 19,200, 38,400, 57,600, 115,200 bit/sec
  • FOUNDATION Fieldbus
  • HART
  • Modbus ASCII/RTU
  • Modbus Via RS-485 as 2-Wire Data Bus According to EIA/TIA-485

Conduit Connection

  • 1/2” NPT Female
  • M20 x 1.5 Female

Consumption

  • 10 W, Max.
  • 25 VA, Max.

Damping Adjustment

  • 0 to 200 seconds

Density Range

  • 0.3 to 2.5 kg/L

Display

  • LCD Display

Electrical Connectors

  • 20 AWG, Shielded, Twisted, Overall Shielding, Flame Propagation According to IEC 60332-1

Electrical Protection

  • Lightning Protection - Arresters 2,000 A are Inside of the Converter for Power Supply Lines

Electrical Rating

  • 5 A at 250 V - External Circuit Breaker Rating

Enclosure, Body Material

  • 304 Stainless Steel, 1.4301 - Detector Insulation Housing

Environmental Protection

  • Explosion-proof
  • Flameproof
  • Intrinsically Safe
  • IP54 (Install Roof Protected)
  • IP66
  • IP67
  • NEMA 4X

Flange Size - 1-1/2” (DN 40)

  • 1-1/2” (DN 40) - 150# ASME
  • 1-1/2” (DN 40) - 1500# ASME
  • 1-1/2” (DN 40) - 300# ASME
  • 1-1/2” (DN 40) - 600# ASME
  • 1-1/2” (DN 40) - 900# ASME
  • 1-1/2” (DN 40) - JIS 10K
  • 1-1/2” (DN 40) - JIS 20K
  • 1-1/2” (DN 40) - PN 100
  • 1-1/2” (DN 40) - PN 40

Flange Size - 1” (DN 25)

  • 1” (DN 25) - 150# ASME
  • 1” (DN 25) - 1500# ASME
  • 1” (DN 25) - 300# ASME
  • 1” (DN 25) - 600# ASME
  • 1” (DN 25) - 900# ASME
  • 1” (DN 25) - JIS 10K
  • 1” (DN 25) - JIS 20K
  • 1” (DN 25) - PN 100
  • 1” (DN 25) - PN 40

Flange Size - 1/2” (DN 15)

  • 1/2” (DN 15) - 150# ASME
  • 1/2” (DN 15) - 1500# ASME
  • 1/2” (DN 15) - 300# ASME
  • 1/2” (DN 15) - 600# ASME
  • 1/2” (DN 15) - 900# ASME
  • 1/2” (DN 15) - JIS 10K
  • 1/2” (DN 15) - JIS 20K
  • 1/2” (DN 15) - PN 100
  • 1/2” (DN 15) - PN 40

Flange Size - 2-1/2” (DN 65)

  • 2-1/2” (DN 65) - 150# ASME
  • 2-1/2” (DN 65) - 300# ASME
  • 2-1/2” (DN 65) - 600# ASME
  • 2-1/2” (DN 65) - 900# ASME

Flange Size - 2” (DN 50)

  • 2” (DN 50) - 150# ASME
  • 2” (DN 50) - 1500# ASME
  • 2” (DN 50) - 300# ASME
  • 2” (DN 50) - 600# ASME
  • 2” (DN 50) - 900# ASME
  • 2” (DN 50) - JIS 10K
  • 2” (DN 50) - JIS 20K
  • 2” (DN 50) - PN 100
  • 2” (DN 50) - PN 40
  • 2” (DN 50) - PN 63

Flange Size - 3” (DN 80)

  • 3” (DN 80) - 150# ASME
  • 3” (DN 80) - 300# ASME
  • 3” (DN 80) - 600# ASME
  • 3” (DN 80) - 900# ASME
  • 3” (DN 80) - JIS 10K
  • 3” (DN 80) - JIS 20K
  • 3” (DN 80) - PN 100
  • 3” (DN 80) - PN 40
  • 3” (DN 80) - PN 63

Flange Size - 4” (DN 100)

  • 4” (DN 100) - 150# ASME
  • 4” (DN 100) - 300# ASME
  • 4” (DN 100) - 600# ASME
  • 4” (DN 100) - JIS 10K
  • 4” (DN 100) - JIS 20K
  • 4” (DN 100) - PN 100
  • 4” (DN 100) - PN 16
  • 4” (DN 100) - PN 40
  • 4” (DN 100) - PN 63

Flange Size - 5” (DN 125)

  • 5” (DN 125) - 150# ASME
  • 5” (DN 125) - 300# ASME
  • 5” (DN 125) - 600# ASME
  • 5” (DN 125) - JIS 10K
  • 5” (DN 125) - JIS 20K
  • 5” (DN 125) - PN 100
  • 5” (DN 125) - PN 16
  • 5” (DN 125) - PN 40
  • 5” (DN 125) - PN 63

Flange Size - 6” (DN 150)

  • 6” (DN 150) - 150# ASME
  • 6” (DN 150) - 300# ASME
  • 6” (DN 150) - 600# ASME
  • 6” (DN 150) - JIS 10K
  • 6” (DN 150) - JIS 20K
  • 6” (DN 150) - PN 100
  • 6” (DN 150) - PN 16
  • 6” (DN 150) - PN 40
  • 6” (DN 150) - PN 63

Flange Size - 8” (DN 200)

  • 8” (DN 200) - 150# ASME
  • 8” (DN 200) - 300# ASME
  • 8” (DN 200) - 600# ASME
  • 8” (DN 200) - PN 16
  • 8” (DN 200) - PN 40
  • 8” (DN 200) - PN 63

Flange Type

  • RTJ - Ring Typical Joint

Frequency

  • 20 to 10,000 Hz - Frequency Output 1
  • 20 to 2,000 Hz - Frequency Output 2

Humidity

  • 0 to 95 % Relative Humidity - Ambient Humidity Range

Linearity

  • 0.05 % of Span Equal to 0.008 mA

Materials of Construction

  • 304 Stainless Steel, 1.4301 - Name Plate, Mounting Bracket
  • 316L Stainless Steel, 1.4401 - Detector Terminal Box, Rupture Disk

Media

  • Gas
  • Liquids
  • Slurry

Mounting Position

  • Horizontal

NACE & NIST

  • NIST

NPT Connection

  • 1/2” NPT Female
  • 1/4” NPT Female
  • 3/4” NPT Female

Operating Temperature - Display

  • -20° to 55° C (-4° to 131° F)

Operating Temperature - Electronics

  • -40° to 55° C (-40° to 131° F)

Output

  • 30 Vdc / 200 mA - Passive Transistor Contact Output, According EN 60947-5-6
  • 4-20 mA DC, Galvanically Separated from Other Signals
  • Active Output, 12 V, 6 mA, Resistance > 10 kiloohms

Plug Material

  • 303 Stainless Steel, 1.4305 - Detector Gas Filling Plug

Power

  • 2 A, T, Breaking Capacity 1,500 A - Fuse on Base Board (AC & DC-Typical)

Power Supply

  • 20.5-28.8 Vdc - DC-Typical
  • 24 Vdc
  • 90-250 Vac, 50/60 Hz - AC Ex-Typical
  • 90-264 Vac - AC-Typical

Pressure Range

  • psi: 0 to 5,583 (kPa: 0 to 38,500, bar: 0 to 385) - Process Pressure Limit

Principle of Operation

  • Coriolis Principle

Process Connection Material

  • 316L Stainless Steel, 1.4404, 1.443, According ASME B16.5

Process Temperature

  • -50° to 150° C (-58° to 302° F)

Pulse Range

  • 0 to 10,000 Pulses/seconds - Output 1
  • 0 to 2,000 Pulses/second - Output 2

Repeatability

  • ± 0.0002 g/cm³ - Density Calibration
  • ± 0.0005 g/cm³
  • ± 0.05 % ± (Zero Stability/2)/Flow Rate *100 % - Repeatability of Liquids

Resistance

  • 100 kiloohms - Status Input (Open)
  • > 100 megaohms / 500 Vdc between Power & Ground Terminal (Isolation Resistance of Converter)
  • > 20 megaohms / 100 Vdc between Power & I/O Terminals, I/O Terminals & Ground (Isolation Resistance of Converter)
  • 20 to 600 ohms - Load Resistance (I/O Signal)

Supply Voltage

  • 1,500 Vac for 1 Minute between Power & Ground Terminal (Dielectric Strength)
  • 10.5-30 Vdc (without HART), 165 mA
  • 16.75-30 Vdc (with HART), 165 mA

Temperature Effect

  • < 0.05 % of Span Per 10° C (18° F) - Ambient Temperature Effect (I/O Signal)
  • ± 0.000015 g/cm³ * Absolute [T-Medium - 20° C (4° F)] - Process Temperature Influence (Density Calibration)

Temperature Range

  • 0° to 150° C (32° to 302° F) Standard

Tri-Clamp Connection

  • 1” Tri-Clamp
  • 1/2” Tri-Clamp
  • 1-1/2” Tri-Clamp
  • 2” Tri-Clamp
  • 3” Tri-Clamp
  • 4” Tri-Clamp

Wetted Materials

  • 316L Stainless Steel, 1.4404, 1.4435
  • Hastelloy C-22 / 2.4602
show more