Brand: Yokogawa Electric CorporationDecades of Yokogawa's innovative measuring technology has resulted in a flexible data logger that offers both reliability and ease of use.
Features- Output format: relay contact (C contact)
- Rated load voltage: 30 Vdc or 250 Vac or less
- Maximum load current: 3 A (DC) / 3 A (AC), resistive load, each
- Minimum load voltage/current: 5 Vdc / 10 mA
- Number of common: 6 (all outputs independent)
Specifications
Ambient Temperature Range
- -20° to 60° C (-4° to 140° F)
Approvals & Certifications
- CE
- CSA
- EMC Directive: EN 61326-1 Class A, EN 61000-3-2, EN 61000-3-3, EN 55011 Class A Group 1
- GOST
- KC
- NRTL
- UL
Channels
- 6
Communication
- Bluetooth
- DARWIN
- Ethernet - 10Base-T/100Base-TX Port
- EtherNet/IP
- Modbus RTU
- Modbus TCP/IP
- RS-422, RS-485
- Serial Communication Port
- SSL
- USB 2.0
Current
- 3 A (AC/DC) - Max.
Display
- 7-Segment LED
Electrical Connectors
- M3 Screw Terminal
Electrical Contacts
- Normally Closed
- Normally Open
Frequency
- 50/60 Hz ± 1 %
Humidity
- 20 to 85 % Relative Humidity, Non-Condensing - Ambient Humidity
Input
- 0.32 to 5.2 V to Standard Signal
- 0-20 mA DC
- -200 mV to 50 V - DCV
- 4-20 mA DC - Standard Signal
Insulation Resistance
- 20 megaohms or Greater at 500 Vdc between Output Terminals & Internal Circuitry
Load
- 5 Vdc / 10 mA Min. - Load Voltage/Current
Measurement Accuracy
- DCV: ± (0.01 % of Reading + 2 mV) - 6 V (1-5 V)
- DCV: ± (0.01 % of Reading + 5 μV) - 20 mV
- ± [0.02 % of Reading + 0.16° C (0.288° F)] - Pt100 (High Resolution)
- ± [0.02 % of Reading + 0.2° C (0.36° F)] - Pt100
- ± 0.2° C (± 0.36° F), However, -200° to 0° C (-328° to 0° F): ± [0.10 % of Reading + 0.2° C (0.36° F)] - T Thermocouple
- ± 0.2° C (± 0.36° F), However, -200° to 0° C (-328° to 0° F): ± [0.15 % of Reading + 0.2° C (0.36° F)] - K Thermocouple [-200° to 500° C (-328° to 932° F)]
- ± 1.1° C (± 1.98° F) - R Thermocouple
Mounting
- Clamp Terminal
- DIN Rail
- Wall Mounted
Output Format
- Relay Contact (C Contact)
RTD Type
- Cu10
- Cu100
- Cu25
- Cu50
- Cu53
- JPt100
- Ni100
- Ni120
- Pt100
- Pt200
- Pt25
- Pt46
- Pt50
Sensor, Probe Type
- B Thermocouple
- E Thermocouple
- J Thermocouple
- K Thermocouple
- L Thermocouple
- N Thermocouple
- RTD
- R Thermocouple
- S Thermocouple
- T Thermocouple
- U Thermocouple
- W Thermocouple
Shock
- When On, 98 m/sec² or Less, 11 milliseconds, 3 times in 6 Directions (± X, ± Y, ± Z)
Supply Voltage
- 180-264 Vac
- 3,000 Vac, 1 Minute between Output Terminals & Internal Circuitry - Withstand Voltage
- 30 Vdc or 250 Vac or Less - Rated Load Voltage
- 90-132 Vac
Switch Type
- SPDT, Relay
Temperature Range
- -200° to 850° C (-328° to 1,562° F) - RTD
- -270° to 2,320° C (-454° to 4,208° F) - Thermocouples
Update Time
- 30 minutes - Warmup Time
Vibration