WA5A/V Distributor with Square Root Extractor

Brand: Yokogawa Electric Corporation

The WA5A/WA5V is a compact, front terminal connection type distributor that is used in combination with a two-wire transmitter, and extracts the square root of 4 to 20 mA DC input signals from the transmitter and converts them into isolated DC current or DC voltage signals.
Features
  • Zero/span adjustment, I/O monitoring can be made using the optional Parameter Setting Tool (VJ77) or Handy Terminal (JHT200)
  • Dual output and 2,000 Vac withstand voltage specifications are available

Specifications

Accuracy

  • ± 0.1 % of Span
  • ± 1 % of Span - Input Level 2 % or Less
  • Relative Error between Output 1 & 2 is within ± 0.2 % - Dual Output

Consumption

  • 100 mA at 24 Vdc - Current Consumption
  • 5 VA at 100 Vac - Power Consumption
  • 6 VA at 100 Vac - Power Consumption
  • 7 VA at 200 Vac - Power Consumption
  • 8 VA at 200 Vac - Power Consumption
  • 90 mA at 24 Vdc - Current Consumption

Current

  • 25-35 mA - Current Limiter for Transmitter Power Supply

Electrical Connectors

  • M4 Screw Terminal

Enclosure, Body Material

  • ABS Resin

Humidity

  • 5 to 90 % Relative Humidity, Non-Condensing

Input

  • 40 mA DC - Max.

Input Signal

  • 4-20 mA DC Signal from 2-Wire Transmitter

Insulation Resistance

  • 100 megaohms or more at 500 Vdc between Input & Output, Output & Power Supply, Power Supply & Ground, & Ground & Input

Mounting

  • DIN Rail Mounting
  • M4 Screw x 4
  • Rack Mounting
  • Wall Mounting

Operating Temperature

  • 0° to 50° C (32° to 122° F)

Output

  • 0 to 24 mA DC
  • 10 mV-20 V - Span (DC)
  • -10-10 Vdc
  • 1-24 mA DC - Span

Power Supply

  • 100-240 Vac (-15 %, 10 %), 50/60 Hz
  • 24 Vdc ± 10 %
  • 25.25 ± 0.25 Vdc - Transmitter Power Supply

Power Supply Effect

  • ± 0.1 % of Span or Less for Fluctuation within the Operating Range of Power Supply Voltage

Resistance

  • 2 to 250 kiloohms or more - Allowable Load Resistance DC Voltage Output
  • 250 ohms - Input Resistance
  • 750 to 15,000 ohms or Less - Allowable Load Resistance for DC Current Output

Response Time

  • 200 milliseconds, 63 % Response (10 to 90 %)

Span & Zero Adjustments

  • ± 1 % of Span - Input Adjustment
  • ± 10 % of Span - Output Adjustment

Supply Voltage

  • 1,500 Vac/minute - AC & DC Drive Withstand Voltage
  • 500 Vac/minute - DC Drive Withstand Voltage

Temperature Effect

  • ± 0.2 % of Span or Less for a Temperature Change of 10° C (18° F) - Effect of Ambient Temperature Change

Zero Offset

  • 0 to 200 % - Zero Elevation (Current Signal)
  • -100 to 200 % - Zero Elevation (Voltage Signal)
show more