Price
$1,762.00 CAD
Stock
25+ In Stock

  • Resolution - 12.7 mm (4-20 mA, Economical Type)
  • Terminal Housing - Digital Display (IP67)
  • Connection Size - 3" (80A)
  • Connection Type - 5 kg/cm²
  • Tube Type - F16 Flexible Tube (PTFE)
  • Float Type - F74 x 45 x 28, PP, 0.64 S.G.
  • Length Type - Up to 9,999 mm
  • Length - 2500 Custom Length in mm

Specifications

Brand

Accuracy

  • ± 0.1 % at 25° C (75.2° F)

Ambient Temperature Range

  • -40° to 80° C (-40° to 176° F)

Approvals & Certifications

  • ABS
  • BV
  • CE
  • DNV
  • GL
  • LR
  • UL

BSP Connection

  • 3” BSP Male (80 A)
  • 4” BSP Male (100 A)
  • 5” BSP Male (125 A)
  • 6” BSP Male (150 A)
  • 7” BSP Male (175 A)
  • 8” BSP Male (200 A)

Communication

  • HART
  • RS-485

Enclosure, Body Material

  • Aluminum

Environmental Protection

  • Digital Display Typical: IP67
  • Economical Typical: IP65

Flange Size - 7” (DN 175)

  • 7” (DN 175) - 150#
  • 7” (DN 175) - 300#
  • 7” (DN 175) - JIS 10K
  • 7” (DN 175) - JIS 5K
  • 7” (DN 175) - PN 10
  • 7” (DN 175) - PN 16
  • 7” (DN 175) - PN 25
  • 7” (DN 175) - PN 40

Fluid Specific Gravity

  • 0.62 to 0.95

Humidity

  • Ambient Humidity: 0 to 80 % Relative Humidity for TAB-2110 Transducer

Materials of Construction

  • Flexible Tube (Ø 16): PTFE
  • Float: 316 Stainless Steel
  • Float: Polypropylene (PP)

Measuring Range

  • 3,000 to 30,000 mm

NPT Connection

  • 3” NPT Male (80 A)
  • 4” NPT Male (100 A)
  • 5” NPT Male (125 A)
  • 6” NPT Male (150 A)
  • 7” NPT Male (175 A)
  • 8” NPT Male (200 A)

Operating Temperature

  • -40° to 80° C (-40° to 176° F)

Output

  • 4-20 mA Loop Power

Power Supply

  • 12-36 Vdc

PT/PF/PS (JIS) Connection

  • 3” PF Male (80 A)
  • 3” PT Male (80 A)
  • 4” PF Male (100 A)
  • 4” PT Male (100 A)
  • 5” PF Male (125 A)
  • 5” PT Male (125 A)
  • 6” PF Male (150 A)
  • 6” PT Male (150 A)
  • 7” PF Male (175 A)
  • 7” PT Male (175 A)
  • 8” PF Male (200 A)
  • 8” PT Male (200 A)

Resolution

  • 12.7 mm

Sensor, Probe Style

  • Float

Span & Zero Adjustments

  • Span Adjustment: 20 % of Full Scale
  • Zero Adjustment: 5 % of Full Scale

Temperature Effect

  • 0.01 % of Full Scale/°C for TAB-2110 Transducer

show more