Price
$823.00 CAD
Stock
100+ In Stock

  • Model - Feet & Inches metre with Backlight & Open Collector Output

Specifications

Accuracy

  • ± 0.03 % of Calibrated Span ± 1 Count

Adjustment

  • Buttons

Alarm

  • Alarm Acknowledge Button Press

Approvals & Certifications

  • ATEX II 2 GD, Ex d IIC T6 Gb, Ex Tb IIIC T85° C Db Ta = -40° to 75° C
  • CE
  • CSA: Class I, Div. 1, Groups B, C, D, Class II, Div. 1, Groups E, F, G, Class III, Div. 1, T6, Class I, Zone 1, Ex d IIC T6 Ta = -40° to 75° C
  • FM Explosion-proof for use in Class I, Div. 1, Groups B, C, D, Class II, Div. 1, Groups E, F, G, Class III, Div. 1, T6, Class I, Zone 1, AEx d IIC T6 Gb Zone 21, AEx Tb IIIC T85° C Ta = -40° to 75° C
  • IEC Ex d IIC T6 Gb, Ex Tb IIIC T85° C Db Ta = -40° to 75° C

Conduit Connection

  • 3/4” NPT

Consumption

  • 0.2 W, Max.
  • 0.25 W, Max.
  • 0.5 W, Max.
  • 0.75 W, Max.

Deadband

  • 0 to 100 % of Full Scale

Display

  • 0.60” (15.2 mm) High
  • 14-Segment Alphanumeric Characters
  • 20-Segments, F (Full) & E (Empty) - Tank Level Indicator
  • -9,999,999 (Underrange) to 9,999,999 (Overrange) - Display Volume
  • Alarm Indication: HI & LO Symbol is Displayed
  • Backlight: White, Loop, or DC Powered
  • Bar Graph
  • Feet & Inches Display
  • LCD Display
  • Lower 7-Digit Display (0.4” High)

Electrical Connectors

  • 12 to 22 AWG
  • Screw Terminal

Enclosure Finish

  • Corrosion Resistant Epoxy Coating

Enclosure, Body Material

  • Explosion-proof Die Cast Aluminum with Glass Window

Environmental Protection

  • IP66
  • IP68
  • NEMA 4X
  • NEMA 7
  • NEMA 9

Frequency

  • 64 dB at 50/60 Hz - Normal Mode Rejection

Function

  • Password Protection

Humidity

  • 0 to 90 % Non-Condensing Relative Humidity

Input

  • 2 A, Max.
  • 3-24 mA
  • 4-20 mA Loop-Powered

Linearization

  • 2 to 32-Points Each for Level & Volume - Multi-Point Linearization

Mounting

  • 1-1/2” to 2-1/2” NPS or DN 40 to 65 mm Pipe Mounting
  • Mounted Directly to Conduit
  • Pipe
  • Wall Mounted

Mounting Position

  • Horizontal

Operating Temperature

  • -40° to 75° C (-40° to 167° F)

Output

  • Open Collector Alarm Output

Programming

  • Four Internal Pushbuttons when Cover is Removed
  • Four SafeTouch through-glass buttons when cover is installed
  • Front Panel ENTER Button & Resets Output & Screen Indication - Acknowledge

Rating

  • Isolated Open Collector: 30 Vdc at 150 mA - Max.

Resistance

  • 150 ohms at 20 mA without Loop Powered Backlight - Equivalent Resistance
  • 300 ohms at 20 mA with Loop Powered Backlight - Equivalent Resistance

Rotation

  • 90° - Display Rotation

Storage Temperature

  • -40° to 75° C (-40° to 167° F)

Supply Voltage

  • 12 Vdc
  • 24 Vdc
  • 30 Vdc
  • 9 Vdc
  • 9-36 Vdc

Thermal Drift

  • 50 ppm/°C from -40° to 75° C (-40° to 167° F) Ambient

Update Time

  • Ambient -25° C: 1 second for 2 Updates - Display Update Rate

Voltage Drop

  • 3.0 Vdc at 20 mA with DC Powered Backlight - Max.
  • 6.0 Vdc at 20 mA with Loop-Powered Backlight - Max.
show more