  • Model - Analog Input Rate/Totalizer with Backlight

Specifications

Accuracy

  • ± 0.03 % of Calibrated Span ± 1 Count
  • 10 % to 100 % of Calibrated Span

Adjustment

  • Buttons

Alarm

  • Alarm Acknowledge Button Press

Approvals & Certifications

  • ATEX II 2 GD, Ex d IIC T6 Gb, Ex Tb IIIC T85° C Db Ta = -40° to 75° C
  • CE
  • CSA Class I, Div. 1, Groups B, C, D, Class II, Div. 1, Groups E, F, G, Class III, Div. 1, T6, Class I, Zone 1, Ex d IIC T6 Ta = -40° to 75° C
  • FM Explosion-proof for use in Class I, Div. 1, Groups B, C, D, Class II, Div. 1, Groups E, F, G, Class III, Div. 1, T6, Class I, Zone 1, AEx d IIC T6 Gb Zone 21, AEx Tb IIIC T85° C Ta = -40° to 75° C
  • IEC Ex d IIC T6 Gb, Ex Tb IIIC T85° C Db Ta = -40° to 75° C

Communication

  • HART

Conduit Connection

  • 3/4” NPT

Consumption

  • 0.2 W, Max.
  • 0.25 W, Max.
  • 0.5 W, Max.
  • 0.75 W, Max.

Deadband

  • 0 to 100 % of Full Scale

Display

  • 14-Segment Alphanumeric Characters
  • -9,999 to 99,999
  • Alarm Indication: HI & LO Symbol is Displayed
  • Backlight: White
  • LCD Display Backlight
  • Lower: Seven Characters 0.40” (10.2 mm) High
  • Upper: 0.70”, 7-Segment, Automatic Lead Zero Blanking
  • Upper: Five Digits, 0,70” (17.8 mm) High

Electrical Connectors

  • 12 to 22 AWG
  • Screw Terminal

Enclosure Finish

  • Corrosion Resistant Epoxy Coating

Enclosure, Body Material

  • Explosion-proof Die Cast Aluminum with Glass Window

Environmental Protection

  • Explosion-proof
  • IP66
  • IP68
  • NEMA 4X
  • NEMA 7
  • NEMA 9

Frequency

  • 2 to 128 Hz - Pulse Ouput
  • 64 dB at 50/60 Hz - Normal Mode Rejection

Function

  • Linearization
  • Live Input Calibration
  • Password Protection
  • Programmable Exponent
  • Square Root

Humidity

  • 0 to 90 % Non-Condensing Relative Humidity

Input

  • 2 A, Max.
  • 4-20 mA Loop Powered

K-Factor

  • Programmable from 0.0001 to 99999 - Pulse Output

Linearization

  • Up to 32-Points

Mounting

  • 1-1/2” to 2-1/2” NPS or DN 40 to 65 mm Pipe Mounting
  • May be Mounted Directly to Conduit
  • Pipe
  • Wall Mounted

Mounting Position

  • Horizontal

Operating Temperature

  • -40° to 75° C (-40° to 167° F)

Output

  • Open Collector

Programming

  • Four Internal Pushbuttons when Cover is Removed
  • Four SafeTouch through-glass buttons when cover is installed
  • Front Panel ENTER Button & Resets Output & Screen Indication - Acknowledge

Pulse Range

  • 250 milliseconds at 2 Hz - Max.
  • 3.9 milliseconds at 128 Hz - Min. Pulse Width
  • 31 milliseconds at 16 Hz - Factory Default Pulse Width

Rating

  • Isolated Open Collector: 30 Vdc at 150 mA - Max.

Resistance

  • 150 ohms at 20 mA without Loop Powered Backlight - Equivalent Resistance
  • 300 ohms at 20 mA with Loop Powered Backlight - Equivalent Resistance

Rotation

  • 90° to 270° - Display Orientation

Storage Temperature

  • -40° to 85° C (-40° to 185° F)

Supply Voltage

  • 12 Vdc
  • 24 Vdc
  • 30 Vdc
  • 9 Vdc
  • 9-36 Vdc

Thermal Drift

  • 50 ppm/°C

Update Time

  • Ambient -25° C: 1 second for 1 Update - Display Update Rate

Voltage Drop

  • 3.0 Vdc at 20 mA without Loop Powered Backlight - Max.
  • 6.0 Vdc at 20 mA with Loop Powered Backlight - Max.
show more