EJA210E Differential Pressure Transmitter

Brand: Yokogawa Electric Corporation

The high performance flange mounted differential pressure transmitter EJA210E can be used to measure levels of densities of solidifying or precipitating liquids. EJA210E outputs a 4-20 mA DC signal corresponding to the measured differential pressure. 

Its accurate and stable sensor can also measure the static pressure which can be shown on the integral indicator or remotely monitored via BRAIN or HART communications. Other key features include quick response, remote set-up using communications and self-diagnostics. 

FOUNDATION Fieldbus, PROFIBUS PA and 1-5 Vdc with HART (Low Power) protocol types are also available.

All EJA-E series models in their standard configuration, with the exception of the Fieldbus, PROFIBUS and Low Power types, are certified as complying with SIL 2 for safety requirement.
Features
  • ± 0.075% Accuracy
  • ± 0.1% per 1 year Stability
  • 120 msec Response Time
  • Exida and TUV SIL2 / SIL3 Certified
  • Signal Characterizer for the 4 to 20 mA output
  • Local Parameter Setting (LPS)

Specifications

Accuracy

  • ± (0.025 + 0.005 URL/Span) % of Span (Includes Terminal-based Linearity, Hysteresis, & Repeatability) - Capsule M
  • ± (0.025 + 0.01 URL/Span) % of Span (Includes Terminal-based Linearity, Hysteresis, & Repeatability) - Capsule H
  • ± 0.075 % of Span

Flange Material

  • 304 Stainless Steel
  • 316 Stainless Steel
  • ASTM CF-8M (Cast Version of 316 Stainless Steel, Equivalent to SCS14A)
  • JIS S25C

Gasket Material

  • 316L Stainless Steel - Hoop
  • PTFE Teflon -Filler, Process Connector Gasket
  • Teflon-Coated SUS316L - Capsule Gasket

NACE & NIST

  • NACE MR-0175

Nut & Bolt Material

  • 316L Stainless Steel
  • 660 Stainless Steel
  • B7 Carbon Steel

Alarm

  • Down-Scale: -5 %, 0.8 Vdc or Less - for 1-5 V HART
  • Down-Scale: -5 %, 3.2 mA DC or Less - for 4-20 mA HART/BRAIN
  • Up-Scale: 110 %, 21.6 mA DC or more - for 4-20 mA HART/BRAIN
  • Up-Scale: 110 %, 5.4 Vdc or more - for 1-5 V HART

Zero Offset

  • External Zero is Continuously Adjustable with 0.01 % Incremental Resolution of Span

Flange Size - 4” (DN 100)

  • 4” (DN 100) - 150# ANSI/JPI
  • 4” (DN 100) - 300# ANSI/JPI
  • 4” (DN 100) - JIS 10K
  • 4” (DN 100) - JIS 20K
  • 4” (DN 100) - PN 10
  • 4” (DN 100) - PN 16
  • 4” (DN 100) - PN 25
  • 4” (DN 100) - PN 40

Cable Material

  • Polyethylene Insulated PVC Sheathed

Drain, Vent Valves & Plug

  • 316 Stainless Steel

Output Load

  • 1 Megaohm or Greater - for 1-5 V HART

O-Ring Material

  • Buna-N - Cover O-Ring
  • Fluororubber - Cover O-Ring

Flange Size - 2” (DN 50)

  • 2” (DN 50) - 150# ANSI/JPI
  • 2” (DN 50) - 300# ANSI/JPI
  • 2” (DN 50) - JIS 10K
  • 2” (DN 50) - JIS 20K
  • 2” (DN 50) - PN 10
  • 2” (DN 50) - PN 16
  • 2” (DN 50) - PN 25
  • 2” (DN 50) - PN 40

Process Temperature

  • -10° to 250° C (14° to 482° F) - High Pressure Side
  • -40° to 120° C (-40° to 248° F) - Low Pressure Side

Communication

  • BRAIN
  • FOUNDATION Fieldbus
  • HART
  • PROFIBUS PA

Operating Temperature

  • -20° to 80° C (-4° to 176° F) - Oil-Prohibited Use

Electrical Connectors

  • 1/2” NPT Female
  • 1/4” NPT - Vent/Drain Plugs
  • G 1/2” Female
  • M20 Female
  • R 1/4” - Vent/Drain Plug

Pressure Range

  • Inches WC: -2,000 to 2,000
  • kPa: -500 to 500
  • mbar: -5,000 to 5,000
  • mmWC: -10,000 to 10,000
  • psi: -72.52 to 72.52

Static Pressure Effect

  • ± 0.007 % of URL Per psi: 100 (kPa: 690, bar: 6.9) - Effect on Zero
  • ± 0.028 % of Span Per psi: 100 (MPa: 0.69, bar: 6.9) - Span Effect

Input Impedance

  • 10 kiloohms or more at 2.4 kHz

Enclosure Finish

  • Anti-Corrosion Coating
  • Polyurethane Paint, Deep Sea Moss Green (Munsell 0.6 GY3.1/2.0 or its Equivalent)

BSP Connection

  • 1/2” BSPT Female
  • 1/4” BSPT Female

Fill Material

  • Fluorinated Oil
  • Propylene Glycol
  • Silicone Oil

Damping Adjustment

  • 0 to 100 seconds

Process Connection Material

  • ASTM CF-8M (Cast Version of 316 Stainless Steel, Equivalent to SCS14A)

Temperature Effect

  • ± [0.14 % of Span + 0.028 % of URL] Per 28° C (50° F) - Capsule H Ambient Temperature Effect
  • ± [0.224 % of Span + 0.056 % of URL] Per 28° C (50° F) - Capsule M Ambient Temperature Effect

Approvals & Certifications

  • Leak Test
  • Material Certificate
  • Pressure Test
  • SIL 2 Capability for Single Transmitter Use, SIL 3 Capability for Dual Transmitter Use, IEC 61508: 2000

Materials of Construction

  • 316 Stainless Steel - Name Plate & Tag

Humidity

  • 0 to 100 % Relative Humidity - Ambient Humidity

Mounting

  • Flange Mount

Enclosure, Body Material

  • ASTM CF-8M Stainless Steel
  • Low Copper Cast Aluminum Alloy

Stability

  • ± 0.1 % of URL Per Year

Supply Pressure

  • psi: 0.38 to 14.5 (kPa: 2.7 to 100, bar: 0.026 to 1)

Pressure Type

  • Absolute
  • Differential
  • Gauge

Approvals & Certifications

  • ATEX Flameproof & Intrinsically Safe
  • CSA Explosion-proof & Intrinsically Safe
  • EMC EN 61326-1 Class A, EN 61326-2-3, EN 61326-2-5
  • FM Explosion-proof & Intrinsically Safe
  • IECEx Intrinsically Safe & Flameproof
  • NAMUR NE43
  • PED 2014/68/EU, 97/23/EC

NPT Connection

  • 1/2” NPT Female
  • 1/4” NPT Female

Supply Voltage

  • 10.5 -32 Vdc - for Lightning Protector
  • 10.5-30 Vdc - for Intrinsically Safe, Typical N, Non-Incendive
  • 10.5-42 Vdc - for General Use & Flameproof Typical
  • 16.6 Vdc Min. - for Digital Communications, BRAIN & HART
  • 24 Vdc - up to 550 ohms
  • 9-28 Vdc for General Use & Flameproof Typical

Power Supply Effect

  • ± 0.005 % Per Volt (From 21.6 to 32 Vdc, 350 ohms)

Environmental Protection

  • IP66
  • IP67
  • NEMA 4X

Flange Size - 3” (DN 80)

  • 3” (DN 80) - 150# ANSI/JPI
  • 3” (DN 80) - 300# ANSI/JPI
  • 3” (DN 80) - JIS 10K
  • 3” (DN 80) - JIS 20K
  • 3” (DN 80) - PN 10
  • 3” (DN 80) - PN 16
  • 3” (DN 80) - PN 25
  • 3” (DN 80) - PN 40

Diaphragm Material

  • 316L Stainless Steel
  • Hastelloy C-276
  • Tantalum

Ambient Temperature Range

  • -30° to 80° C (-22° to 176° F) with LCD Display
  • -40° to 85° C (-40° to 185° F)

Load

  • 0 to 1,290 ohms - for Operation
  • 0.22 μF or Less - Load Capacitance
  • 250 to 600 ohms - for Digital Communication
  • 3.3 MH or Less - Load Inductance

Wetted Materials

  • 316 Stainless Steel - Flushing Connection Ring, Pipe
  • 316L Stainless Steel - Capsule
  • F316L Stainless Steel - Capsule
  • Hastelloy C-276
  • Tantalum
show more