EJX610A High Performance Pressure Transmitter

Brand: Yokogawa Electric Corporation

The high performance gauge pressure transmitter absolute pressure transmitter EJX610A feature single crystal silicon resonant sensor and are suitable to measure liquid, gas, or steam pressure. 

EJX610A output a 4 to 20 mA DC signal corresponding to the measured pressure. They also feature quick response, remote setup and monitoring via BRAIN or HART communications, diagnostics, and optional status output for pressure high/low alarm.

The multi-sensing technology provides the advanced diagnostic function to detect such abnormalities as an impulse line blockage or heat trace breakage. 

FOUNDATION Fieldbus and PROFIBUS PA protocol types are also available. All EJX series models in their standard configuration, with the exception of the Fieldbus and PROFIBUS types, are certified by TÜV as complying with SIL 2 for safety requirement.
Features
  • ± 0.04% Accuracy
  • ± 0.2% per 15 years Stability
  • 90 ms Response Time
  • 15,200 psia Maximum Over Pressure
  • Exida and TUV SIL 2/3 Certified
  • Local Parameter Setting (LPS)

Specifications

Accuracy

  • ± (0.005 + 0.0035 URL/Span) % of Span (Includes the Effects of Terminal-based Linearity, Hysteresis, & Repeatability) - Capsule B, C, D
  • ± (0.02 + 0.007 URL/Span) % of Span (Includes the Effects of Terminal-based Linearity, Hysteresis, & Repeatability) - Capsule A
  • ± 0.04 % of Span (Includes the Effects of Terminal-based Linearity, Hysteresis, & Repeatability)

Adjustment Type

  • Push Button
  • Screw

Alarm

  • Down-Scale: -5 %, 3.2 mA DC or Less
  • Up-Scale: 110 %, 21.6 mA DC or more

Ambient Temperature Range

  • -30° to 80° C (-22° to 176° F) with LCD Display
  • -40° to 85° C (-40° to 185° F)

Approvals & Certifications

  • Leak Test
  • Material Certificate
  • Pressure Test
  • SIL 2 Capability for Single Transmitter Use, SIL 3 Capability for Dual Transmitter Use
  • TÜV (Technischer Uberwachungsverein)

Approvals & Certifications

  • ATEX Flameproof & Intrinsically Safe
  • CE
  • CSA Explosion-proof & Intrinsically Safe
  • EMC EN 61326-1 Class A, EN 61326-2-3, EN 61326-2-5 (For Fieldbus)
  • FM Explosion-proof & Intrinsically Safe
  • IECEx Intrinsically Safe & Flameproof
  • PED 2014/68/EU, 97/23/EC

BSP Connection

  • G 1/2” Male DIN 16 288

Burst Pressure

  • psi: 26,400 (kPa: 182,000, bar: 1,820) - D Capsule
  • psi: 7,252 (kPa: 50,000, bar: 500) - A, B & C Capsule

Cable Material

  • Polyethylene Insulated PVC Sheathed

Communication

  • BRAIN
  • FOUNDATION Fieldbus
  • HART FSK
  • PROFIBUS PA

Damping Adjustment

  • 0 to 100 seconds

Diagnostics

  • Capsule Temperature
  • Configuration Error
  • CPU Failure
  • Hardware Failure
  • Heat Trace Monitoring
  • Impulse Line Blockage Detection
  • Process Alarm for Pressure
  • User-Configurable Process High/Low Alarm for Pressure

Diaphragm Material

  • Hastelloy C-276

Display

  • 5-Digit Numerical Display
  • 6-Digit Unit Display
  • Bar Graph
  • LCD Display
  • User-Configurable 10-Segment Signal Characterizer

Distance

  • Up to 2 Kilometers - Communication Distance

Electrical Connectors

  • 1/2” NPT Female
  • G 1/2” Female
  • M20 Female

Electrical Protection

  • Lightning Protection

Electrical Rating

  • 10.5-30 Vdc, 120 mA DC, Max.

Enclosure Finish

  • Anti-Corrosion Coating
  • Polyurethane Mint-Green Paint (Munsell 5.6BG 3.3/2.9 or its Equivalent)

Enclosure, Body Material

  • ASTM CF-8M Stainless Steel
  • Low Copper Cast Aluminum Alloy

Environmental Protection

  • IP66
  • IP67
  • NEMA 4X

Fill Material

  • Fluorinated Oil
  • Silicone

Humidity

  • 0 to 100 % Relative Humidity - Ambient Humidity

Input Impedance

  • 10 kiloohms or more at 2.4 kHz - Communicating Device

Load

  • 0 to 1,290 ohms - for Operation
  • 0.22 µF or Less - Load Capacitance
  • 250 to 600 ohms - for Digital Communication
  • 3.3 MH or Less - Load Inductance

Materials of Construction

  • 316 Stainless Steel - Name Plate & Tag, Mounting Bracket
  • Polypropylene - Pipe

Media

  • Gas
  • Liquids
  • Steam

Metric Connection

  • M20 x 1.5 Male DIN 16288

Mounting

  • 2” (50.8 mm) Pipe Mounting Bracket

Mounting Position Effect

  • Tilting up to 90° will cause Zero Shift up to 0.21 kPa

NACE & NIST

  • NACE MR-0103
  • NACE MR-0175, ISO 15156

NPT Connection

  • 1/2” NPT Female
  • 1/2” NPT Male

O-Ring Material

  • Buna-N - Cover O-Ring
  • Fluororubber - Cover O-Rings

Operating Temperature

  • -20° to 80° C (-4° to 176° F)

Output Format

  • Transistor Output

Output Signal

  • 4-20 mA DC (2-Wire)

Overpressure & Static Pressure Limits

  • psia: 15,200 (MPa: 105, bar: 1,050) - Max.
  • psia: 2,300 (MPa: 16, bar: 160) - Max.
  • psia: 3,600 (MPa: 25, bar: 250) - Max.
  • psia: 580 (MPa: 4, bar: 40) - Max.

Power Supply Effect

  • ± 0.005 % Per Volt (21.6-32 Vdc, 350 ohms)

Pressure Range

  • bar: 0 to 700
  • kPa: 0 to 70,000
  • psia: 0 to 10,150

Pressure Type

  • Absolute

Process Connection Material

  • 316L Stainless Steel
  • Hastelloy C-276

Process Temperature

  • -40° to 120° C (-40° to 248° F)

Response Time

  • 90 milliseconds

Screw Material

  • 316 Stainless Steel - Zero-Adjustment Screw & Set Screws

Stability

  • ± 0.2 % of URL for 10-Years

Supply Pressure - Maximum

  • psia: 1,450 (kPa: 10,000, bar: 100) - Capsule C
  • psia: 10,150 (kPa: 70,000, bar: 700) - Capsule D
  • psia: 29 (kPa: 200, bar: 2) - Capsule A
  • psia: 290 (kPa: 2,000, bar: 20) - Capsule B

Supply Voltage

  • 10.5-30 Vdc - for Intrinsically Safe, Typical N, Non-Incendive
  • 10.5-32 Vdc - for Lightning Protector
  • 10.5-42 Vdc - for General Use & Flameproof Typical
  • 16.6 Vdc - Min. Voltage for Digital Communications, BRAIN & HART
  • 24 Vdc - up to A 550 ohms Load Can be Used

Temperature Effect

  • ± (0.04 % of Span + 0.009 % of URL) Per 28° C (50° F) - Ambient Temperature Effect for C & D Capsule
  • ± (0.04 % of Span + 0.018 % of URL) Per 28° C (50° F) - Ambient Temperature Effect for B Capsule
  • ± (0.04 % of Span + 0.075 % of URL) Per 28° C (50° F) - Ambient Temperature Effect for a Capsule

Update Time

  • 45 milliseconds - Pressure

Vibration Effect

  • < ± 0.1 % of URL Per IEC 60770-1 with Low Vibration Level (10-60 Hz, 0.15 mm Displacement / 60-500 Hz 2 G)
  • < 0.1 % of URL Per IEC 60770-1 with High Vibration Level (10-60 Hz, 0.21 mm Displacement / 60 to 2,000 Hz 3 G)

Wetted Materials

  • 316L Stainless Steel
  • Hastelloy C-276

Zero Offset

  • External Zero is Continuously Adjustable with 0.01 % Incremental Resolution of Span

Output

  • 3.6-21.6 mA
show more