YPP6870 Large Display Process Meter

Brand: Yokogawa Electric Corporation

The YPP6870 is a rugged, loop-powered meter with 1" display digits in an explosion-proof enclosure for demanding applications in hazardous areas or in the harshest environmental conditions. 

The meter derives all of its power from the 4-20 mA loop with a small 1 volt drop for easy installation in almost any system. 

It is programmed using four easy to access front-mounted control dials with no complex or difficult to read programming menus necessary for setup. 

The numeric display will read from -1999 to 1999 over a 2000 count user adjustable scaling span. 

The backlight option lets you see the display under any lighting condition and is powered from the 4-20 mA loop with no additional power supply required. 

The enclosure is provided with two threaded conduit holes and integrated pipe or wall mounting slotted flanges.
Features
  • 4-20 mA Input
  • Modern, Sleek and Practical Enclosure
  • 3½ Digits, 1" (25.4 mm) Display
  • Display Mountable at 0°, 90°, 180°, & 270° Degrees.
  • Easy Calibration and Installation
  • Loop-Powered Backlight Option
  • 1 V Drop (4 V with Backlight)
  • Explosion-Proof, IP68, NEMA 4X Enclosure
  • Flanges for Wall or Pipe Mounting
  • HART® Protocol Transparent
  • Operates from -40 to 75°C

Specifications

Accuracy

  • ± 0.1 % of Full Span ± 1 Count

Ambient Temperature Range

  • -40° to 75° C (-40° to 167° F)

Approvals & Certifications

  • ATEX II 2 GD. Ex d IIC T6 Gb. Ex Tb IIIC T85° C Db IP68. Ta=-40° to 75° C (-40° to 167° F). Certificate Number: Sira 13-ATEX-1121X
  • CE
  • CSA Class I, Div. 1, Groups B, C, D, Class II, Div. 1, Groups E, F, G, Class III, Div. 1, T6. Class I, Zone 1, Ex d IIC T6. Ta=-40° to 75° C (-40° to 167° F). Certificate Number: 2605742
  • FM Explosion-proof Class I, Div. 1, Groups B, C, D, Class II, Div. 1, Groups E, F, G, Class III, Div. 1, T6. Class I, Zone 1, AEx d IIC T6 Gb. Zone 21, AEx Tb IIIC T85° C. Ta=-40° to 75° C (-40° to 167° F). Certificate Number: 3048884
  • IEC Ex SIR 13.0042X. Ex d IIC T6 Gb. Ex Tb IIIC T85° C Db IP68. Ta=-40° to 75° C (-40° to 167° F)

Calibration

  • 4 mA Input: -1,000 to 1,000, 20 mA between 20 & 2,000 Counts greater than 4 mA Display

Communication

  • HART

Conduit Connection

  • Two 3/4” NPT Threaded Conduit Openings & One 3/4” NPT Nickel-Plated Brass Conduit Plug with 10 mm Hex Key Fitting Installed

Display

  • -1,999 to 1,999
  • 3-1/2” Digit LCD, 1” (25.4 mm)
  • Backlit

Electrical Connectors

  • 12 to 22 AWG
  • Screw Terminal

Enclosure Finish

  • Corrosion Resistant Epoxy Coating

Environmental Protection

  • Explosion-proof
  • IP66
  • IP68
  • NEMA 4X

Humidity

  • 0 to 90 % Non-Condensing Relative Humidity

Input

  • 4-20 mA
  • Over Current Protection to 2 A, Max.

Mounting

  • Pipe Mounting: 1-1/2” to 2-1/2” NPS or DN 40 to 65 mm
  • Wall Mounted

NPT Connection

  • 3/4” NPT

Operating Temperature

  • -40° to 75° C (-40° to 167° F)

Rotation

  • 90° Increments up to 270° from Default Orientation

Storage Temperature

  • -40° to 75° C (-40° to 167° F)

Thermal Drift

  • 150 ppm/°C from -40° to 75° C (-40° to 167° F) Ambient

Update Time

  • Display: 2.5 Updates/second

Voltage Drop

  • 1 Vdc at 20 mA with Backlight - Max.
  • 4 Vdc at 20 mA with Loop-Powered Backlight - Max.
show more