TY530 Digital Multimeter

Brand: Yokogawa Electric Corporation

The TY series, simply performing special operations via front panel allows for quick and reliable adjustment.

In addition, the series allows for one touch adjustment of AC voltage- and AC current-to-frequency characteristics.

The user calibration function leads to improved operation efficiency and cost reduction.
Features
  • High Precision
  • Basic accuracy 0.09%
  • True RMS measurement
  • Ensured Field Site Safety
  • Conforms to safety standards EN61010-1, 1000V CAT III, 600V CAT IV
  • Safety shutters for preventing erroneous insertion of test leads into current measurement terminals
  • New Functions for Yokogawa Middle Class DMMs
  • Current direct reading function provided by current clamp sensor (optional)
  • Low-pass Filter (LPF)
  • Logging-mode memory for 1600 data
  • USB communication, application software (Optional DMM communication package) TY530 only
  • Closed Case Calibration
  • 3-year Warranty

Specifications

Accuracy

  • ± (0.09 % of Reading + 2-Digits) - DC Voltage Measurement
  • ± (0.15 % of Reading + 2-Digits) - DC Voltage Measurement
  • ± (0.2 % of Reading + 2-Digits) - Frequency Measurement
  • ± (0.5 % of Reading + 5-Digits) - DC Current Measurement
  • ± (1 % of Reading + 5-Digits) - AC Voltage Measurement, Diode Test
  • ± (1.5 % of Reading + 5-Digits) - AC Current Measurement
  • ± (2 % of Reading + 2-Digits) - Resistance

Approvals & Certifications

  • EN 61010-031

Approvals & Certifications

  • CE
  • CSA
  • EMC: EN 61326-1 Class B, EN 55011 Class B Group 1, EN 61326-2-1
  • UL 61010-1, CAN/CSA C22.2 No. 61010-1, UL 61010-031, CAN/CSA C22.2 No. 61010-031, cULus

Battery Life

  • Approximately 300 Hours (For Continuous DC Voltage Measurement with Alkaline Cells)

Communication

  • USB

Current

  • < 1.2 mA - Max.
  • 600 µA - 10 A - DC Current, AC Current Measurement

Display

  • 3.5-Digit LCD 7-Segment
  • Backlit
  • Bar Graph: 31 Segment
  • Digital Display: [6,000] Counts

Function

  • Auto Hold
  • Auto Power Off
  • Communication Function
  • Data Hold
  • Data Memory
  • Filter
  • Maximum
  • Overvoltage Input Warning
  • PC Connection
  • Relative Value Computation

Humidity

  • 70 % Relative Humidity, Non-Condensing - Storage & Operating Conditions
  • 80 % Relative Humidity, Non-Condensing - Operating Conditions

Indication

  • Low Battery Indicator
  • Overrange Indicator: ”OL”
  • Polarity Indicator

Input

  • 0.2 to 600 Vrms to Frequency Measurement
  • 1,000 Vdc - Max.
  • 1,000 Vrms - Input Protection Voltage for Resistance, Temperature Measurement, Diode Test, Continuity Check, Capacitance
  • 1,000 Vrms AC - Max.
  • 10 A Fuse Protected - Max.
  • 440 mA Fuse Protected - Max.

Input Impedance

  • 10 megaohms, < 200 PF & < 50 PF - AC Voltage Measurement
  • 11 megaohms, < 50 PF - AC Voltage Measurement

Measuring Range

  • Bar Graph Display: 25 times/second
  • Capacitance: Max.
  • DC Voltage, Diode Test: 5 times/second
  • Frequency: 1 Time/second
  • Resistance: 2.5 times/second
  • Temperature: 0.7 times/second

Operating Temperature

  • -10° to 55° C (14° to 131° F)
  • 40° to 55° C (104° to 131° F)

Power Supply

  • 4 AA Alkaline Batteries (R6) Dry Cells

Resistance

  • 10 megaohms - Input Resistance
  • 11 megaohms - Input Resistance

Resolution

  • 0.001 V - Diode Test
  • 0.1 A - AC Current, DC Current Measurement
  • 0.1 Hz - Frequency Measurement
  • 0.1 ohms - Resistance Measurement, Continuity Check
  • 0.1° C - Temperature Measurement
  • 1 µF - Capacitance
  • 1 V - AC Voltage, DC Voltage Measurement

Response Time

  • 1 seconds - DC Voltage & Current
  • 10 seconds or Less for 6 to 60 megaohms Resistance Measurement
  • 2 seconds - AC Voltage, Resistance
  • 3 seconds or Less - AC Current Measurement

Sensor, Probe Type

  • K Thermocouple

Storage Temperature

  • -30° to 70° C (-22° to 158° F)

Supply Voltage

  • < 1.3 V - Open Circuit Voltage for Resistance Measurement
  • < 3.5 V - Open Circuit Voltage for Resistance Measurement, Diode Test, Continuity Check
  • 6.88 kV for 5 seconds (Between Input Terminals & Casing)
  • 600 mV-1,000 V - DC Voltage, AC Voltage Measurement

Voltage Drop

  • < 0.1 V/A - DC Current, AC Current Measurement
  • < 0.12 mV/µA - DC Current, AC Current Measurement
  • < 3.3 mV/mA - DC Current, AC Current Measurement
show more