MU5 Free Range Universal Temperature Converter

Brand: Yokogawa Electric Corporation

The MU5 is a plug-in type universal temperature converter that converts input signal (thermocouple, RTD or mV signal) into isolated DC current or DC voltage signals.
Features
  • Selection of input type(thermocouple, RTD or mV signal), I/O range setting, burnout setting, output adjustment, I/O monitoring, and loop back test can be made using the optional Parameter Setting Tool (VJ77) or Handy Terminal (JHT200).
  • The operation indicating lamp shows the operation status, abnormalities in a setting etc.
  • Output adjustment, wiring resistance correction, and ON/OFF of RJC can be made using the switches on the front panel of the MU5 without a setting tool such as Handy Terminal.
  • For the Fahrenheit display, specify the option “/DF”.

Specifications

Accuracy

  • ± 0.05 % - Output Accuracy
  • ± 0.05 % of Span or ± 0.05° C (± 0.09° F) whichever is greater - for Pt50 (JIS’81)
  • ± 0.1 % of Span
  • ± 0.1 % of Span or ± 1° C (± 1.8° F) whichever is greater - Typical K, E & T: less than -200° C (-328° F), Typical B: 400° C (752° F) to less than 600° C (1,112° F), Typical E & J: more than 750° C (1,382° F), Typical N: more than 1,200° C (2,192° F)
  • ± 0.1 % of Span or ± 2° C (± 3.6° F) whichever is greater - Typical N: less than -200° C (-328° F)

Burn-Out

  • 60 seconds - Max.
  • Downscale
  • Off
  • Upscale

Consumption

  • 1.6 W at 110 Vdc - Power Consumption
  • 1.7 W at 24 Vdc - Power Consumption
  • 3.5 VA at 100 Vac - Power Consumption
  • 4.9 VA at 200 Vac - Power Consumption

Current

  • 0.7 mA Approximately - RTD Detective Current

Electrical Connectors

  • M3.5 Screw Terminal

Humidity

  • 5 to 90 % Relative Humidity, Non-Condensing - Operating Humidity

Input

  • ± 4 Vdc - Max.
  • -500 to 500 mVdc - Measuring Range

Insulation Resistance

  • 100 megaohms at 500 Vdc between Input, Output, Power Supply & Grounding Terminals Mutually

Materials of Construction

  • ABS Resin (Black), UL 94 V-0 - Main Unit
  • ABS Resin + Polycarbonate Resin (Black), UL 94 V-0 - Main Unit
  • Modified Polyphenylene Oxide Resin, Including Glass Fiber (Black), UL 94 V-1 - Socket
  • PBT Resin, Including Glass Fiber (Black), UL 94 V-0 - Main Unit

Measuring Span

  • 10° C (50° F) or more (RTD)
  • 3 mV or more (Thermocouple, mV Signal)

Mounting

  • DIN Rail Mounting
  • Plug-In Typical
  • Wall Mounted

Operating Temperature

  • 0° to 50° C (32° to 122° F)

Operating Voltages

  • 12-48 V
  • 85-264 V

Output

  • ± 10 Vdc, Span is 0.1 V or more
  • ± 100 mVdc, Span is 10 mV or more
  • 0-20 mA DC, Span is 5 mA or more
  • 0-5 mA DC - Span is 1 mA or more
  • 15 V/Max.

Power Supply

  • 100-240 Vac/dc (-15, 20 %), 50/60 Hz - Power Supply Input & Rated Voltage
  • 15-40 Vdc (± 20 %) - Power Supply Input & Rated Voltage

Power Supply Effect

  • ± 0.1 % of Span or Less for the Fluctuation within the Operating Range of Each Power Supply Voltage Specification - Effect of Power Supply Voltage Fluctuations

Resistance

  • ± 0.2° C (0.36° F) or Less for a Change of 10 ohms / Wire - Effect of Leadwire Resistance for RTD
  • ± 15 µV or Less for a Change of 100 ohms - Leadwire Resistance Change Effect for Thermocouple
  • 1 Megaohm During Power On - Input Resistance
  • 10 kiloohms During Power Off (Thermocouple, mV Signal) - Input Resistance
  • 10 kiloohms or more for ± 10 Vdc - Allowable Load Resistance for Voltage Output
  • 2 kiloohms or more for ± 5 Vdc - Allowable Load Resistance for Voltage Output
  • 250 kiloohms or more for ± 100 mVdc - Allowable Load Resistance for Voltage Output
  • 500 ohms or Less - Input External Resistance

Response Time

  • 150 milliseconds, 63 % Response (10 to 90 %)

RTD Type

  • JPt100 (JIS’89)
  • Pt100 (ITS-90: JIS’97 & IPTS-68: JIS’89)
  • Pt50 (JIS’81)

Sensor, Probe Type

  • B Thermocouple (ITS-90: JIS’97)
  • E Thermocouple (ITS-90: JIS’97)
  • J Thermocouple (ITS-90: JIS’97)
  • K Thermocouple (ITS-90: JIS’97)
  • N Thermocouple (ITS-90: JIS’97)
  • RTD
  • R Thermocouple (ITS-90: JIS’97)
  • S Thermocouple (ITS-90: JIS’97)
  • Thermocouples
  • T Thermocouple (ITS-90: JIS’97)
  • W3 Thermocouple
  • W5 Thermocouple

Span & Zero Adjustments

  • ± 1 % of Span or More - Input Adjustment
  • ± 5 % of Span or More - Output Adjustment

Supply Voltage

  • 2,000 Vac for 1 Minute between Input, Output, Power Supply & Grounding Terminals Mutually - Withstand Voltage

Temperature Effect

  • ± 0.15 % of Span or Less for a Temperature Change of 10° C (50° F) - Ambient Temperature Effect

Temperature Range

  • -200° to 850° C (-328° to 1,562° F) - RTD Measuring Range
  • -270° to 2,300° C (-454° to 4,172° F) - Thermocouple Measuring Range