Accuracy
- ± (0.05 % of Reading + 1 MHz)
- ± (0.1 % of Reading + 0.1 % of Range)
- ± 0.01 % (Reading) in the Guaranteed Accuracy Range from 1 to 130 % - Basic Power Accuracy
- ± 0.02 % of Reading - Time Accuracy
- ± 0.05 % of Range when the Input Signal Levels are greater than or Equal to 25 mV
- ± 4 % (At Dmax = 4 %) at 23° ± 1° C (73.4° ± 1.8° F) of Ambient Temperature for Dc, Dmax
- ± 5 % (At Pst = 1) at 23° ± 1° C (73.4° ± 1.8° F) of Ambient Temperature
- 0.03 % of Reading Value of Apparent Power - Low Power Factor Error
Applications
- Accurate Measurement of Fundamental PWM Voltage
- Evaluation of Torque Speed Characteristics
- High Frequency & Harmonic Measurements
- Phase Voltage Measurement without A Neutral Line
- Power Conversion Technologies Similar to Those used in Electric Vehicles (EVs) & Power Conditioners
- Simultaneous Input & Output Measurement
Approvals & Certifications
- AS
- BS
- CSA
- IEC 61600-3-3, IEC 61000-3-11, IEC 61000-3-2, IEC 61000-3-12, IEC 61000-4-7
- IEEE Standard 488.2-1992
- NBR
- PSE
- UL
- VDE
Channels
- 20-Channels (Each Channel Can be Set Separately) - Number of Outputs
- 2-Channels - Number of Measurement Channels
- 4-Channels - Number of Measurement Channels
Communication
- 100Base-TX
- 10Base-T
- Baud Rate: 1,200, 2,400, 4,800, 9,600, 19,200, 38,400 bit/sec
- Baud Rate: 10/100 Mbps
- Data Length: 9,000 - FFT Data Length
- Ethernet TCP/IP
- Full Duplex
- GPIB
- RS-232 (EIA-232 Standard for 9-Pin)
- Start-Stop Synchronization
- Word Length: 32-bits - FFT Processing Word Length
Computation Cycle
- 1 second - Measurement Period for the Computation
- 100 milliseconds - Measurement Period for the Computation
Consumption
- 100 mA - Max.
- 150 VA (When Using Built-in Printer) - Max.
Current
- 2.5 mA-1 A (For Crest Factor 6) - Direct Input Current (2 A Input Element)
- 250 mA-15 A (For Crest Factor 6) - Direct Input Current (30 A Input Element
- 5 mA-2 A (For Crest Factor 3) - Direct Input Current (For 2 A Input Element)
- 500 mA-30 A (For Crest Factor 3) - Direct Input Current (30 A Input Element)
Display
- 8.4-inch TFT Color Liquid Crystal Display
- Bar Graph
- Numerical
- Trend
- Vector Display
Electrical Connectors
- D-Sub 15-Pin Connector
- D-Sub 9-Pin Connector
- Insulated BNC Connector
- Plug Connection
- Plug-In Terminal (Safety Terminal) - Input Terminal
- RJ45 Connector
- Typical B Connector
Filter
- Anti-Aliasing Filter Set Using A Line Filter (OFF, 500 Hz, 5.5 kHz, or 50 kHz)
Frequency
- 10 to 2,600 Hz - Fundamental Frequency of the PLL Source
- 2 to 200 kHz
- 48 to 63 Hz - Allowed Supply Frequency Fluctuation
- DC, 0.1 Hz to 1 MHz - Measurement Bandwidth
Function
- Absolute Value (ABS)
- Addition (+)
- Division (/)
- Exponential Average AVG2, AVG4, AVG8, AVG16, AVG32, AVG64
- Multiplication (x)
- Natural Logarithm (LOG), Common Logarithm (LOG10)
- Negation (NEG)
- Square Root (SQRT)
- Subtraction (-)
Humidity
- 20 to 80 % Relative Humidity, Non-Condensing - Storage & Operating Humidity
- 30 to 75 % Relative Humidity
Input
- ± 12 Vpeak - Amplitude Input Range
- ± 22 V - Continuous, Max.
- ± 42 Vpeak or Less - Continuous, Max.
- 1 V (Peak-to-Peak) or more - Effective Amplitude
- 1,000 V - Voltage & Current Input Terminal for Rated Voltage to Ground
- 1,000 Vrms - Voltage & Current Input Terminal for Continuous, Max.
- 110-130 V at the 150 V Measuring Range
- 1-20 V
- 2 A - Input Element
- 220-250 V at the 300 V Measuring Range
- 30 A - Input Element
- 50 mV-10 V - External Current Sensor Input
- 50 % Duty Ratio Square Wave - Input Waveform
- 600 V (Rated Voltage of EN 61010-2-030 Standard) - Current Input Terminal for Rated Voltage to Ground
- 600 Vrms (Rated Voltage of EN 61010-2-030 Standard) - Current Input Terminal for Continuous, Max.
- Floating Input - Voltage
- Peak Value of 1,600 V or RMS Value of 1,100 V, whichever is less - Continuous, Max.
- Peak Value of 150 A or RMS Value of 50 A, whichever is less - Instantaneous, Max.
- Peak Value of 2,500 V or RMS Value of 1,500 V, whichever is less - Instantaneous, Max.
- Peak Value of 9 A or RMS Value of 3 A, whichever is less - Instantaneous, Max.
- Shunt Input - Current
- Square Wave
- TTL
Input Impedance
- 0.5 ohms - Direct Input 2 A Input Element
- 1 Megaohm - External Current Sensor Input
- 40 PF Approximately - Input Capacitance
- 5 PF Approximately - Input Capacitance
Measuring Time
- 0 to 3,600 seconds - Timeout Time
Media
- Indoor - Installation Location
Operating Temperature
- 5° to 40° C (41° to 104° F)
Port
- 1-Port - Number of Communication Ports
Pulse Range
- 1 microsecond - Min. Pulse Width for Triggers
Remote Control & Monitoring Software
- External Hold - Remote Control
- External Print - Remote Control
- External Reset - Remote Control
- External Single - Remote Control
- External Start - Remote Control
- External Stop - Remote Control
Resistance
- 1 Megaohm - Input Resistance
- 10 megaohms Approximately - Input Resistance for Voltage
Resolution
- 0.1 % - Setting Resolution
- 1 Hz - Frequency Resolution
- 10 Hz - Frequency Resolution
- 16-bits - D/A Conversion Resolution
Sensor Input
- 25 mV-5 V (For Crest Factor 6) - External Current Sensor Input (For 2 A & 30 A Input Element)
- 50 mV-10 V (For Crest Factor 3) - External Current Sensor Input (For 2 A & 30 A Input Element)
Storage Temperature
- -25° to 60° C (-13° to 140° F)
Supply Voltage
- 100-240 Vac
- 15-1,000 V - for Crest Factor 3
- 7.5-500 V - for Crest Factor 6
- 90-264 Vac - Fluctuation Range
System Requirements
- Windows® 8 (32-bits/64-bits)
- Windows® 8.1/Windows® 7 Operating System
- Windows® Vista
Temperature Coefficient
- ± 0.03 % of Range/°C
- ± 0.05 % of Full Scale/°C
- 0.02 % of Reading/°C at 5° to 18° C (41° to 64.4° F) or 28° to 40° C (82.4° to 104° F) - Voltage, Current & Power
Update Time
- 2 seconds (dc, Dmax, D(t) & Tmax) - Display Update
- 30 minutes Approximately - Warm-Up Time
- 50 milliseconds to 20 seconds
Wiring
- Single-Phase & Three-Phase, 3-Wire
- Single-Phase, 2-Wire
- Three-Phase, 4-Wire