VJP8 Pulse Rate Converter

Brand: Yokogawa Electric Corporation

The VJP8 is a plug-in pulse rate converter that receives contact, voltage or current pulse from a field, and converts it into isolated transistor-contact pulse or contactless AC switch pulse at a preset pulse rate. 

The VJP8 can also be used as a pulse signal repeater by setting the pulse rate and pulse width type.
Features
  • Either Pulse Output or Communication Function (RS-485) is Selectable as Output-2
  • Various Parameters Such As Pulse Rate Can be Set and Modified Through a PC (VJ77) or Handy Terminal (JHT200 and the Like)

Specifications

Accuracy

  • ± 0.1 % of Span
  • ± 10 % - Pulse Width Time Accuracy
  • ± 20 % - for 15-30 Vdc

Approvals & Certifications

  • CE Marking EN 61326-1
  • EMC
  • KC Marking

Communication

  • 2-Wire Half-Duplex
  • Baud Rate: 1,200, 2,400, 4,800 & 9,600 bit/sec
  • Data Length: 7-bits, 8-bits
  • EIA RS-485
  • LADDER Communication Protocol
  • Modbus ASCII/RTU
  • PC-Link Communication Protocol
  • PC-Link with Sum Communication Protocol
  • Stop Bit: 1-bit, 2-bits

Current

  • 50 mA - Max.

Dissipation

  • 100 Vac 6.5 VA
  • 110 Vdc 3.7 W
  • 200 Vac 8.6 VA
  • 24 Vdc 3.7 W

Distance

  • 3,937 feet (1,200 metres) - Max.

Electrical Connectors

  • M3 Screw Terminal

Enclosure, Body Material

  • Modified Polyphenylene Oxide

Frequency

  • 0 to 1 kHz - Contactless AC Switch Output Frequency
  • 0 to 100 kHz - Open Collector Output Frequency
  • 10 kHz - Input Frequency

Humidity

  • 5 to 90 % Relative Humidity Non-Condensing

Input

  • -1 to 8 Vdc - Low Level (On Input)
  • 10-50 mA DC - High Level (off Input) & Pulse Width
  • 15-30 Vdc (± 20 %) - Power Supply Input Voltage
  • 2-50 Vdc - High Level (off Input) & Pulse Width
  • 2-Wire Typical
  • 3-Wire Typical
  • -5 to 40 mA DC - Low Level (On Input)
  • 58 Vdc or Less - Max.

Insulation Resistance

  • 100 megaohms at 500 Vdc between Input, Output-1, Output-2, Power Supply & Ground Mutually

Load

  • Maximum

Measuring Time

  • 12.5 / 30 / 50 / 100 milliseconds - Pulse Width Time
  • 12.5 / 50 / 100 µs - Pulse Width Time

Mounting

  • Dedicated VJ Mounting Base - Only when Output-2 is Analog Output
  • DIN Rail
  • Wall Mounted

Output Format

  • Contactless AC Switch
  • Open Collector

Power Supply

  • 100-240 Vac/dc, 50/60 Hz - Power Supply Rated Voltage
  • 12 Vdc ± 10 % - Transmitter Power Supply (For 4-30 mA Output)
  • 15 Vdc / 15 mA - Power Supply for Contact Input Signal
  • 15-30 Vdc - Power Supply Rated Voltage
  • 24 Vdc ± 10 % - Transmitter Power Supply (For 4-30 mA Output)

Pulse Range

  • 0.0001 to 2.0000 (Settable to Four Decimal Places) - Pulse Rate Setting Range

Resistance

  • 100 kiloohms - Contact Resistance (OFF Input)
  • 15 kiloohms or more - Contact Pulse or Voltage Pulse (Input Resistance)
  • 200 ohms - Current Pulse (Input Resistance) with External Shunt Resistor Option
  • 200 ohms or Less - Contact Resistance (ON Input)

Supply Voltage

  • 1,000 Vac Per Minute - Withstand Voltage between Output-1 & Output-2
  • 2,000 Vac Per Minute - Withstand Voltage between Input, (Output-1, Output-2), Power Supply, & Ground Mutually

Temperature Effect

  • No Wrong Operation for a Temperature Change of 10° C (18° F) - Effect of Ambient Temperature Change

Temperature Range

  • 0° to 50° C (32° to 120° F)

Update Time

  • Approximately 10 milliseconds - Input Filter Time Contact