EJX530B Wireless Pressure Transmitter

Brand: Yokogawa Electric Corporation

The High performance absolute and gauge pressure transmitters EJX530B feature single crystal silicon resonant sensor and are suitable to measure liquid, gas, or steam pressure. EJX530B and transmit not only process variables but also the setting parameters using wireless signal.

The transmitters run on internal batteries, and the installation cost can be decreased since hard-wiring is not required. The communication is compliant with ISA100.11a protocol specifications.
Features
  • Long Life Battery Design
    • Ultra low current consumption design using two high capacity lithium-thionyl chloride batteries provide wireless operation for years.
  • Security Assured Wireless Network Joining
    • Infrared communication between the devices for wireless network configuration and parameter setting.
  • Quick Update Time
    • Selectable from 0.5 second to 60 minutes for measured process value to publish wirelessly.

Specifications

Accuracy

  • ± (0.004 URL/Span) % of Span (Includes the Effects of Terminal-based Linearity, Hysteresis & Repeatability) - Capsule A & D
  • ± (0.005+0.0035 URL/Span) % of Span (Includes the Effects of Terminal-based Linearity, Hysteresis & Repeatability) - Capsule B & C
  • ± 0.04 % of Span (Includes the Effects of Terminal-based Linearity, Hysteresis & Repeatability) - Reference Accuracy

Ambient Temperature Range

  • -30° to 80° C (-22° to 176° F) - LCD Visible Range
  • -40° to 85° C (-40° to 185° F)

Approvals & Certifications

  • Leak Test
  • Material Certificate
  • Pressure Test
  • R & TTE Directive

Approvals & Certifications

  • ATEX: Intrinsically Safe
  • CE: ETSI EN 300328, ETSI EN 301489-1, ETSI EN 301489-17, EN 61010-1, EN 61010-2-030, EN 62311
  • CSA: Intrinsically Safe
  • EMC: EN 61326-1 Class A (Industrial Locations), EN 61326-2-3
  • FCC Approval: Regulation Conformity of the Wireless Module
  • FM: Intrinsically Safe
  • IC Approval: Regulation Conformity of the Wireless Module
  • IEC Ex: Intrinsically Safe
  • PED 2014/68/EU & 97/23/EC: European Pressure Equipment Directive (Sound Engineering Practice)

Battery Life

  • 10-Years - at 60 seconds Update Time
  • 4-Years - at 10 seconds Update Time

BSP Connection

  • G 1/2” Male

Burst Pressure

  • psi: 19,140 (kPa: 132,000, bar: 1,320) - D Capsule
  • psi: 4,351 (kPa: 30,000, bar: 300) - A, B & C Capsule

Communication

  • Wireless Communication (ISA100.11a Protocol)

Dead Time

  • 100 milliseconds

Diagnostics

  • Amplifier Failure
  • Battery Alarm & Wireless Communication Alarm
  • Capsule Failure
  • Configuration Error
  • Over-Range Error for Process Variables

Diaphragm Material

  • Hastelloy C-276

Display

  • 5-Digit Numerical Display
  • 6-Digit Unit Display
  • Bar Graph
  • LCD Display

Enclosure Finish

  • Anti-Corrosion Coating
  • Polyurethane, Mint Green Paint (Munsell 5.6BG 3.3/2.9 or its Equivalent)

Environmental Protection

  • Hazardous Area
  • IP66
  • IP67
  • NEMA 4X

Fill Material

  • Fluorinated Oil
  • Silicone

Fluid

  • Gas
  • Liquid

Frequency

  • 2,400 to 2,483.5 MHz License Free ISM Band

Function

  • Software Download Functions

Humidity

  • 0 to 100 % Relative Humidity - Ambient Humidity Limits

Materials of Construction

  • 304 Stainless Steel - Mounting Bracket
  • 316 Stainless Steel Tag Plate Wired Onto Transmitter - Name Plate & Tag
  • Polypropylene - Pipe

Metric Connection

  • M20 x 1.5 Male

Mounting

  • 2” Pipe Mounting Bracket

Mounting Position Effect

  • Tilting up to 90° will cause Zero Shift up to 0.21 kPa

NPT Connection

  • 1/2” NPT Female
  • 1/2” NPT Male

O-Ring Material

  • Buna-N - Cover O-Ring

Operating Temperature

  • -20° to 80° C (-4° to 176° F)

Output

  • Wireless (ISA100.11a Protocol) 2.4 GHz Signal

Overpressure & Static Pressure Limits

  • psig: 10,800 (MPa: 75, bar: 750) - Max.
  • psig: 2,900 (MPa: 20, bar: 200) - Max.
  • psig: 580 (MPa: 4, bar: 40) - Max.

Power Requirement

  • 7.2 V, 19 Ah Lithium Thionyl Chloride Batteries (2x Primary)

Pressure Range

  • bar: -1 to 500
  • MPa: -0.1 to 50
  • psig: -14.5 to 7,200

Pressure Type

  • Gauge

Process Connection Material

  • 316L Stainless Steel
  • Hastelloy C-276

Process Temperature

  • -40° to 120° C (-40° to 248° F)

Response Time

  • 150 milliseconds

Stability

  • ± 0.1 % of URL Per 10-Years

Supply Pressure - Maximum

  • psig: 1,450 (MPa: 10, bar: 100) - Capsule C
  • psig: 29 (kPa: 200, bar: 2) - Capsule A
  • psig: 290 (MPa: 2, bar: 20) - Capsule B
  • psig: 7,200 (MPa: 50, bar: 500) - Capsule D

Temperature Effect

  • ± (0.15 % of Span + 0.15 % of URL) Per 28° C (50° F) Change - Ambient Temperature Effects

Update Time

  • 0.5 to 3,600 seconds Selectable - Intermittent
  • 100 milliseconds - Continuous

Vibration Effect

  • < ± 0.1 % of URL Per IEC 60770-1 Field or Pipeline with Low Vibration Level (10-60 Hz 0.15 mm Displacement / 60-500 Hz 2 G)

Wetted Materials

  • 316L Stainless Steel
  • Hastelloy C-276

Zero Offset

  • 0.01 % Incremental Resolution of Span - External Zero Adjustment
show more