ADMAG AXF Standard Flange Magnetic Flow Meter

Brand: Yokogawa Electric Corporation

The ADMAG AXF is the magnetic flow meter which has adopted the proven Dual Frequency Excitation. Moreover, the Enhanced Dual Frequency Excitation has been newly added to tackle more severe applications.

The AXF has user-friendly functions; such as an electrode adhesion level diagnosis function, infra-red switches which can be used for setting parameters without opening the case cover, ability to change the direction of electrical connection on the site.

Based on FOUNDATION™ fieldbus specifications, AXF Fieldbus models offer more flexible instrumentation through a higher level communication capability and propose the cost reduction by multi-drop wirings with less cables.

FOUNDATION™ fieldbus is a registered trademark of Fieldbus FOUNDATION.
Features
  • User-oriented Functionality
  • Fluid Adhesion Level Diagnosis
  • The amount of insulating material on the electrode is constantly monitored to determine when maintenance should be performed. An optional replaceable electrode is easy to remove and clean.
  • Flexible Electrical Connection Direction
  • The converter or the terminal box can be rotated in either direction to match the position of the electrical connections at the installation site.
  • Clear and Versatile Indications
  • The large, backlit full dot matrix LCD can display a variety of messages up to three lines in length. When an alarm condition occurs, a full description of the appropriate countermeasure is displayed.
  • Easy Setup
  • The most frequently used parameters are arranged in a group at the top of the display. Infrared switches enable the setting of parameters without opening the cover.
  • Operation Immediately after Installation
  • The AXF is shipped with the main parameters completely set and can go into operation as soon as installation and wiring are completed.
  • Expansion of Product Lineup
  • Improved Accuracy Specification
  • The standard accuracy is 0.35% of reading. Also available as an option is high accuracy calibration rated at 0.2% of reading.
  • Extra Small Size Flange Type
  • Flange types are now available in sizes as small as 2.5 mm.
  • Variety of Sanitary Connections
  • A wider variety of sanitary connections are now available, including Tri-Clamp, ISO, DIN and SMS.
  • Enhanced Performance
  • Enhanced Dual Frequency Excitation
  • The enhanced dual frequency excitation method is available as an option. This provides highly stable measurements involving high concentration slurries or low conductivity fluids.
  • Lower Minimum Conductivity
  • The newly designed AXF converter permits the measurement of fluids with conductivity as low as 1μS/cm depending on the nominal pipe size and fluid condition.
  • High-Speed Pulse Output
  • The maximum rate for high speed applications such as short-duration batch processes is now 10,000 pps (pulses per second).

Specifications

Accuracy

  • 0.2 % of Reading - for High Accuracy Calibration
  • 0.35 % of Reading - Standard Accuracy

Alarm

  • Down-Scale: -10 %, 2.4 mA DC or Less
  • Up-Scale: 110 %, 21.6 mA DC or more

Ambient Temperature Range

  • -40° to 60° C (-40° to 140° F)

Approvals & Certifications

  • ATEX Ex db E Ia IIC T6 to T4 Gb, EN 60079-0, EN 60079-1, EN 60079-7, EN 60079-11, EN 60079-31, DEKRA 15-ATEX-0029
  • CE
  • CSA - Certificate: 1481213, ANSI/ISA 12.27.01 (Process Sealing), (For CSA C22. 2 Series Explosion-proof for Class I, Div. 1, Groups A, B, C, D, Dust-Ignition-proof for Class II/III, Div. 1, Groups E, F, G, Intrinsically Safe (Electrodes) for Cla
  • EMC - EN 61326-1 Class A, Table 2 (For use in Industrial Locations), EN 61326-2-3, EN 61326-2-5 (For FOUNDATION Fieldbus, PROFIBUS Only), EN 61000-3-2 Class A, EN 61000-3-3
  • FM - 3600, 3610, 3615, 3810, ANSI/NEMA 250, Explosion-proof for Class I, Div. 1, Groups A, B, C, D, Dust-Ignition-proof for Class II/III, Division1, Groups E, F, G, Intrinsically Safe (Electrodes) for Class I, Div. 1, Groups A, B, C, D
  • IEC Ex - 60079-0, 60079-1, 60079-7, 60079-11, 60079-31, Certificate: IEC Ex dEK 15.0022 X
  • NAMUR NE43
  • PED
  • TIIS - Ex de[ia] IIC T4, Explosion-proof, Intrinsically Safety, Flameproof

Approvals & Certifications

  • Calibration
  • Hydrostatic Pressure Test
  • Liquid Penetration Test Certificate
  • Material Certificate
  • PMI
  • Withstand Voltage Test Certificate

Communication

  • BRAIN
  • FOUNDATION Fieldbus
  • HART
  • PROFIBUS PA

Conduit Connection

  • G 3/4” Female

Consumption

  • 12 W
  • 20 W - Remote Flowtube combined with AXFA11

Cover Material

  • Aluminum Alloy - Converter Material & Terminal Box

Current

  • 150 mA or Less - Drive Current

Diagnostics

  • Process, System, Setting Alarm & Warnings

Diameter

  • 0.59” to 11.60” (15 to 294.7 mm) - Inner Diameter of Grounding Ring
  • 1.50” to 13.70” (38 to 348 mm) - Outer Diameter for Effective Sealing

Display

  • Full Dot Matrix LCD (32 x 132 Pixels)

Distance

  • 6” (15 cm) or more - Distance from Power Line
  • Up to 1.5 Kilometers, when Polyethylene Insulated PVC-sheathed Cables (CEV Cables) are used - Communication Distance

Duty Cycle

  • 50 % - Pulse Width

Electrical Connectors

  • ANSI 1/2” NPT Female
  • ISO M20 x 1.5 Female
  • JIS G 1/2” Female
  • M4 Screw Terminal - Terminal Connection

Electrical Protection

  • Lightning Protection

Electrical Rating

  • 200 mA (ON) at 30 Vdc (OFF) - Contact Capacity for One Pulse, One Alarm & Two Status Output Signals

Enclosure Finish

  • Coated in Black (Munsell N1.5 or its Equivalent)
  • Coated in Jade Green (Munsell 7.5 BG 4/1.5 or its Equivalent)
  • Coated in Metallic Silver
  • Corrosion-Resistant Coating - Case & Cover
  • Epoxy Resin Coating
  • High Anti-Corrosion Coating
  • Mint Green Paint (Munsell 5.6 BG 3.3/2.9 or its Equivalent) - Coating Color
  • Non-Tar Epoxy Coating (Black) - for Submersible Typical

Enclosure, Body Material

  • Aluminum Alloy - Converter Material (Remote Flowtube)
  • Carbon Steel (JIS SPCC Equivalent) - for 6” to 16” (150 to 400 mm)
  • JIS SUS304 (AISI 304 Stainless Steel / EN 1.4301 Equivalent) - for 1” to 5” (25 to 125 mm)
  • Stainless Steel, JIS SCS11 Equivalent - for 0.1” to 0.5” (2.5 to 15 mm)

Environmental Protection

  • IP66 - for General-purpose Use / Sanitary Typical / TIIS Flameproof Typical
  • IP67 - for General-purpose Use / Sanitary Typical / TIIS Flameproof Typical
  • IP68 - for Submersible Typical (Only for Remote Flowtube)
  • NEMA 4X

Excitation Voltage

  • 140 V, Max.
  • 170 V, Max.

Flange Material

  • Carbon Steel (JIS SS400 or SFVC 2A) - Flange & Mini-Flange Material
  • JIS SCS13 (EN 1.4308 Equivalent) - Mini-Flange & Pipe Material
  • JIS SUS304 or SUSF304 (AISI 304 Stainless Steel / EN 1.4301 Equivalent) - Flange, Mini-Flange, Pipe Material & Tag Plate
  • JIS SUS316L (316 Stainless Steel) - Mini-Flange
  • JIS SUS430 (ASTM 43000 / DIN X6Cr17 / EN 1.4016 Equivalent) - Mini-Flange
  • JIS SUSF316

Flange Size - 1-1/2” (DN 40)

  • 1-1/2” (DN 40) - 150# ANSI/JPI
  • 1-1/2” (DN 40) - 300# ANSI
  • 1-1/2” (DN 40) - JIS 10K
  • 1-1/2” (DN 40) - JIS 20K
  • 1-1/2” (DN 40) - JIS F12 (JIS75M)
  • 1-1/2” (DN 40) - PN 10
  • 1-1/2” (DN 40) - PN 16
  • 1-1/2” (DN 40) - PN 40

Flange Size - 1-1/4” (DN 32)

  • 1-1/4” (DN 32) - 150# ANSI/JPI
  • 1-1/4” (DN 32) - 300# ANSI
  • 1-1/4” (DN 32) - JIS 10K
  • 1-1/4” (DN 32) - JIS 20K
  • 1-1/4” (DN 32) - JIS F12 (JIS75M)
  • 1-1/4” (DN 32) - PN 10
  • 1-1/4” (DN 32) - PN 16
  • 1-1/4” (DN 32) - PN 40

Flange Size - 1” (DN 25)

  • 1” (DN 25) - 150# ANSI/JPI
  • 1” (DN 25) - 300# ANSI
  • 1” (DN 25) - JIS 10K
  • 1” (DN 25) - JIS 20K
  • 1” (DN 25) - JIS F12 (JIS75M)
  • 1” (DN 25) - PN 10
  • 1” (DN 25) - PN 16
  • 1” (DN 25) - PN 40

Flange Size - 1/10” (DN 2.5)

  • 1/10” (DN 2.5) - 150# ANSI/JPI
  • 1/10” (DN 2.5) - 300# ANSI
  • 1/10” (DN 2.5) - JIS 10K
  • 1/10” (DN 2.5) - JIS 20K
  • 1/10” (DN 2.5) - JIS F12 (JIS75M)
  • 1/10” (DN 2.5) - PN 10
  • 1/10” (DN 2.5) - PN 16
  • 1/10” (DN 2.5) - PN 40

Flange Size - 1/2” (DN 15)

  • 1/2” (DN 15) - 150# ANSI/JPI
  • 1/2” (DN 15) - 300# ANSI
  • 1/2” (DN 15) - JIS 10K
  • 1/2” (DN 15) - JIS 20K
  • 1/2” (DN 15) - JIS F12 (JIS75M)
  • 1/2” (DN 15) - PN 10
  • 1/2” (DN 15) - PN 16
  • 1/2” (DN 15) - PN 40

Flange Size - 1/5”

  • 1/5” (DN 5) - 150# ANSI/JPI
  • 1/5” (DN 5) - 300# ANSI
  • 1/5” (DN 5) - JIS 10K
  • 1/5” (DN 5) - JIS 20K
  • 1/5” (DN 5) - JIS F12 (JIS75M)
  • 1/5” (DN 5) - PN 10
  • 1/5” (DN 5) - PN 16
  • 1/5” (DN 5) - PN 40

Flange Size - 10” (DN 250)

  • 10” (DN 250) - 150# ANSI/JPI
  • 10” (DN 250) - 300# ANSI
  • 10” (DN 250) - JIS 10K
  • 10” (DN 250) - JIS 20K
  • 10” (DN 250) - JIS F12 (JIS75M)
  • 10” (DN 250) - PN 10
  • 10” (DN 250) - PN 16
  • 10” (DN 250) - PN 40

Flange Size - 12” (DN 300)

  • 12” (DN 300) - 150# ANSI/JPI
  • 12” (DN 300) - 300# ANSI
  • 12” (DN 300) - JIS 10K
  • 12” (DN 300) - JIS 20K
  • 12” (DN 300) - JIS F12 (JIS75M)
  • 12” (DN 300) - PN 10
  • 12” (DN 300) - PN 16
  • 12” (DN 300) - PN 40

Flange Size - 14” (DN 350)

  • 14” (DN 350) - 150# ANSI/JPI
  • 14” (DN 350) - 300# ANSI
  • 14” (DN 350) - JIS 10K
  • 14” (DN 350) - JIS 20K
  • 14” (DN 350) - JIS F12 (JIS75M)
  • 14” (DN 350) - PN 10
  • 14” (DN 350) - PN 16
  • 14” (DN 350) - PN 40

Flange Size - 16” (DN 400)

  • 16” (DN 400) - 150# ANSI/JPI
  • 16” (DN 400) - 300# ANSI
  • 16” (DN 400) - JIS 10K
  • 16” (DN 400) - JIS 20K
  • 16” (DN 400) - JIS F12 (JIS75M)
  • 16” (DN 400) - PN 10
  • 16” (DN 400) - PN 16
  • 16” (DN 400) - PN 40

Flange Size - 2-1/2” (DN 65)

  • 2-1/2” (DN 65) - 150# ANSI/JPI
  • 2-1/2” (DN 65) - 300# ANSI
  • 2-1/2” (DN 65) - JIS 10K
  • 2-1/2” (DN 65) - JIS 20K
  • 2-1/2” (DN 65) - JIS F12 (JIS75M)
  • 2-1/2” (DN 65) - PN 10
  • 2-1/2” (DN 65) - PN 16
  • 2-1/2” (DN 65) - PN 40

Flange Size - 2” (DN 50)

  • 2” (DN 50) - 150# ANSI/JPI
  • 2” (DN 50) - 300# ANSI
  • 2” (DN 50) - JIS 10K
  • 2” (DN 50) - JIS 20K
  • 2” (DN 50) - JIS F12 (JIS75M)
  • 2” (DN 50) - PN 10
  • 2” (DN 50) - PN 16
  • 2” (DN 50) - PN 40

Flange Size - 3” (DN 80)

  • 3” (DN 80) - 150# ANSI/JPI
  • 3” (DN 80) - 300# ANSI
  • 3” (DN 80) - JIS 10K
  • 3” (DN 80) - JIS 20K
  • 3” (DN 80) - JIS F12 (JIS75M)
  • 3” (DN 80) - PN 10
  • 3” (DN 80) - PN 16
  • 3” (DN 80) - PN 40

Flange Size - 3/8” (DN 10)

  • 3/8” (DN 10) - 150# ANSI/JPI
  • 3/8” (DN 10) - 300# ANSI
  • 3/8” (DN 10) - JIS 10K
  • 3/8” (DN 10) - JIS 20K
  • 3/8” (DN 10) - JIS F12 (JIS75M)
  • 3/8” (DN 10) - PN 10
  • 3/8” (DN 10) - PN 16
  • 3/8” (DN 10) - PN 40

Flange Size - 4” (DN 100)

  • 4” (DN 100) - 150# ANSI/JPI
  • 4” (DN 100) - 300# ANSI
  • 4” (DN 100) - JIS 10K
  • 4” (DN 100) - JIS 20K
  • 4” (DN 100) - JIS F12 (JIS75M)
  • 4” (DN 100) - PN 10
  • 4” (DN 100) - PN 16
  • 4” (DN 100) - PN 40

Flange Size - 5” (DN 125)

  • 5” (DN 125) - 150# ANSI/JPI
  • 5” (DN 125) - 300# ANSI
  • 5” (DN 125) - JIS 10K
  • 5” (DN 125) - JIS 20K
  • 5” (DN 125) - JIS F12 (JIS75M)
  • 5” (DN 125) - PN 10
  • 5” (DN 125) - PN 16
  • 5” (DN 125) - PN 40

Flange Size - 6” (DN 150)

  • 6” (DN 150) - 150# ANSI/JPI
  • 6” (DN 150) - 300# ANSI
  • 6” (DN 150) - JIS 10K
  • 6” (DN 150) - JIS 20K
  • 6” (DN 150) - JIS F12 (JIS75M)
  • 6” (DN 150) - PN 10
  • 6” (DN 150) - PN 16
  • 6” (DN 150) - PN 40

Flange Size - 8” (DN 200)

  • 8” (DN 200) - 150# ANSI/JPI
  • 8” (DN 200) - 300# ANSI
  • 8” (DN 200) - JIS 10K
  • 8” (DN 200) - JIS 20K
  • 8” (DN 200) - JIS F12 (JIS75M)
  • 8” (DN 200) - PN 10
  • 8” (DN 200) - PN 16
  • 8” (DN 200) - PN 40

Fluid

  • 1 µS/cm or Larger, for Size 0.5” to 5” (15 to 125 mm) - Fluid Conductivity
  • 3 µS/cm or Larger, for Size 6” to 16” (150 to 400 mm) - Fluid Conductivity
  • 5 µS/cm or Larger, for Size 0.1” to 0.4” (2.5 to 10 mm) - Fluid Conductivity
  • Gas
  • Liquid

Gasket Material

  • Chloroprene Rubber
  • PTFE-Sheathed Non-Asbestos Gasket
  • Viton (Acid-Resistant & Alkali-Resistant) - Special Gaskets

Humidity

  • 0 to 100 % - Ambient Humidity

Input Impedance

  • 10 kiloohms or more at 2.4 kHz - Input Impedance of Communicating Device

Input Signal

  • Dry Contact

Insulation Resistance

  • 100 megaohms at 500 Vdc - between Power Supply Terminals & Ground Terminal, between Power Supply Terminals & Input/Output Terminals (Integral Flowmeter), between Excitation Current Terminal & Signal / Common Terminals, between Signal Terminals, between S
  • 20 megaohms at 100 Vdc - between Ground Terminal & Input/Output Terminals, between Input/Output Terminals (Integral Flowmeter)

Load

  • 0.22 µF or Less - Load Capacitance
  • 3.3 MH or Less - Load Inductance

Materials of Construction

  • Ceramic - Joints, Tube (Mirror Finished)

Mounting Position

  • Vertical

Nut & Bolt Material

  • Carbon Steel
  • JIS SUS403 (403 Stainless Steel Equivalent) - Nut
  • JIS/AISI 304 Stainless Steel - Bolt

O-Ring Material

  • Fluororubber for Replaceable Electrode Typical

Operating Voltages

  • 20.4-28.8 Vac - Integral Flowmeter
  • 20.4-28.8 Vdc - Integral Flowmeter
  • 80-264 Vac - Integral Flowmeter
  • 90-130 Vdc - Integral Flowmeter

Output

  • 1.6 Vdc, 200 mA - Max.
  • 30 Vdc, Max.
  • 4-20 mA DC

Output Format

  • Alarm Output
  • Current Output
  • Pulse Output

Power Supply

  • 100-120 Vdc - Integral Flowmeter
  • 100-240 Vac, 47 to 63 Hz - Integral Flowmeter
  • 24 Vac, 50/60 Hz - Integral Flowmeter
  • 24 Vdc - Integral Flowmeter

Pressure Range

  • psi: -14.5 to 580 (MPa: -0.1 to 4, bar: -1 to 40) - Fluid Pressure

Process Connection Material

  • Carbon Steel
  • Stainless Steel

Process Temperature

  • -40° to 110° C (-40° to 230° F)

Pulse Range

  • 0.0001 to 10,000 Pulse/second - Pulse Output Rate
  • 0.05 to 100 milliseconds - Pulse Width

Repeatability

  • ± 0.05 % of Rate ± 0.5 mm/sec (V< 1 m/sec (3.3 feet/sec))
  • ± 0.1 % of Rate (V≥ 1 m/sec (3.3 feet/sec))

Resistance

  • 10 ohms or Less - Grounding Resistance for JIS Class C & JIS Class A
  • 100 kiloohms or more (OFF) - Load Resistance
  • 100 ohms or Less - Grounding Resistance
  • 200 ohms or Less (ON) - Load Resistance
  • 250 to 450 ohms (Including Cable Resistance) - Load Resistance for BRAIN Communication
  • 250 to 600 ohms (Including Cable Resistance) - Load Resistance for HART Communication
  • 750 ohms, Max.

Rotation

  • 180° Rotated Converter (or Terminal Box) to Change the Direction of Electrical Connection
  • 90° Rotated Converter (or Terminal Box) to Change the Direction of Electrical Connection
  • -90° Rotated Converter (or Terminal Box) to Change the Direction of Electrical Connection

Temperature Range

  • 120° C (248° F) - Max.

Time Constant

  • 0.1 to 200 seconds (63 % Response) - Damping Time Constant

Wetted Materials

  • Alumina Ceramic - Lining & Pipe Material
  • EPDM Rubber Lining
  • Fluorocarbon PFA - Lining
  • Hastelloy C-276 Equivalent - Electrode & Grounding Ring / Grounding Electrode
  • JIS SUS316 (316 Stainless Steel) - Grounding Ring / Grounding Electrode
  • JIS SUS316L (316L Stainless Steel) - Electrode & Grounding Ring / Grounding Electrode
  • Natural Soft Rubber - Lining
  • Platinum-Iridium - Electrode & Grounding Ring / Grounding Electrode
  • Polyurethane Rubber - Lining
  • Tantalum - Electrode & Grounding Ring/Grounding Electrode
  • Titanium - Electrode & Grounding Ring / Grounding Electrode
  • Tungsten Carbide - Electrode

Documentation

Technical Information

show more