Accuracy
- ± 0.02 % of Reading - Time Accuracy
- ± 0.06 % of Reading
- ± 0.1 % - Basic Accuracy
- 0.1 % of Reading + 0.1 % of Range - Basic Power Accuracy (50/60 Hz)
- 1 to 110 % - Guaranteed Accuracy Range for Voltage & Current Ranges
- Line Filter is OFF (Power): ± (0.25 % of Reading + 0.5 % of Range) to ± (6 % of Reading + 0.5 % of Range)
- Line Filter is OFF (Voltage & Current): ± (0.15 % of Reading + 0.35 % of Range) to ± (3 % of Reading + 0.35 % of Range)
- Line Filter is ON (Power): ± (0.85 % of Reading + 0.5 % of Range) to ± (10 % of Reading + 0.5 % of Range)
- Line Filter is ON (Voltage & Current): ± (0.4 % of Reading + 0.35 % of Range) to ± (5 % of Reading + 0.35 % of Range)
Approvals & Certifications
Bandwidth
- DC, 0.5 to 100,000 Hz - Measurement Power Bandwidth
Channels
- 1 - Number of Measurement Channel
- 2 - Frequency
- 3 - Number of Measurement Channels
Communication
- 100 Mbps - Transmission Rate
- DHCP
- Ethernet
- FTP
- GPIB
- TCP/IP Protocols
- USB
Consumption
- 80 VA (When Using Built-in Printer) - Max.
Display
- 5.7” TFT Color LCD
- 640 x 480 Pixels
- 99,999 - Max.
- Bar Graph
- Numerical Values
- Trend
- Vector
- Waveform
Electrical Connectors
- BNC Connector
- D-Sub 15-Pin Connector
- Plug-In Connector
- RJ45 Connector
- Typical A Connector
- Typical B Connector
Frequency
- 0.0001 Hz - Min. Frequency Resolution
- 0.5 to 100,000 Hz at 23° ± 5° C (73.4° ± 9° F)
- 10 to 1,200 Hz - Fundamental Frequency
- 10 to 2,500 Hz - Sampling Frequency
- 48 to 63 Hz - Allowed Supply Frequency Fluctuation
- 50/60 Hz - Rated Supply Frequency
Function
- Rectangular - Window Function
Humidity
- 20 to 80 % Relative Humidity, Non-Condensing
Input
- 0.5-40 A - Direct Input
- 1,000 V, Max.
- 1,000 Vrms, Max.
- 25 mV-5 V - for Crest Factor 6 (External Sensor Input)
- 250 mA-20 A - for Crest Factor 6 (Direct Input)
- 40 Arms - Max.
- 50 mV-10 V - for Crest Factro 3 (External Sensor Input)
- 500 mA-40 A - for Crest Factor 3 (Direct Input)
- 600 V (Rated Voltage of EN 61010-2-030 Standard) - Rated Voltage to Ground for Current Input Terminals & External Current Sensor Input Connector
- 600 Vrms (Rated Voltage of EN 61010-2-030 Standard) - Continuous, Max.
- Floating Input
- Peak Current of 100 A or RMS of 45 A, whichever is Lower - Continuous, Max.
- Peak Current of 150 A or RMS of 45 A, whichever is Lower - Instantaneous, Max.
- Peak Current of 450 A or RMS of 300 A, whichever is Lower - Instantaneous, Max.
- Peak Voltage of 1.5 kV or RMS of 1 kV, whichever is Lower - Continuous, Max.
- Peak Voltage of 2 kV or RMS of 1.5 kV, whichever is Lower - Instantaneous, Max.
- Peak Voltage of 2.8 kV or RMS of 2 kV, whichever is Lower - Instantaneous, Max.
- TTL
Input Impedance
- Approximately 100 kiloohms - External Sensor Input for Current
- Approximately 2 megaohms, 13 PF - for Voltage
- Approximately 5 milliohms + Approximately 0.1 μH - Direct Input for Current
Measuring Range
- 15-1,000 V - for Crest Factor 3 (Voltage)
- 7.5-500 V - for Crest Factror 6 (Voltage)
Operating Temperature
- 5° to 40° C (41° to 104° F)
Power Supply
- 5 V, 500 mA (Per Port)
- Self Power
Resolution
- 0.0001 Hz - Min. Frequency Resolution
- 16-bits - A/D Converter
Storage Temperature
- -25° to 60° C (-13° to 140° F)
Supply Voltage
- 100-240 Vac
- 90-264 Vac - Allowed Supply Voltage Fluctuation Range
System Requirements
- Windows® 2000 - Models with Standard USB Ports that Run
- Windows® Vista with USB Port
- Windows® XP
Temperature Coefficient
- ± 0.03 % of Reading/°C at 5° to 18° C (41° to 64.4° F) or 28° to 40° C (82.4° to 104° F)
Update Time
- 100 to 5,000 milliseconds